Download Print this page

Everpure EV9613-01 Performance Data Sheet

Mh and mh2 water filters

Advertisement

Quick Links

WATER TREATMENT PRODUCTS
1040 Muirfield Drive • Hanover Park, IL 60133 • 630.307.3000 • FAX 630.307.3030
MH Cartridge Part No. EV9613-01 (1-pack)
Part No. EV9613-06 (6-pack)
MH
Cartridge Part No. EV9613-21 (1-pack)
2
Part No. EV9613-26 (6-pack)
FEATURES
• Finely polishes treated water to premium quality.
• Reduces chlorine taste and odor.
• Reduces dirt, rust, asbestos fibers, and other particulates
including oxidized iron, manganese, and sulfides.
• Reduces parasitic protozoan cysts such as Giardia, Entamoeba,
and Cryptosporidium.
• Reduces common earthy, moldy, fishy tastes and odors
• Inhibits limescale build-up in ice machines – As tested by
Everpure.
• MH
2
cartridges are treated with bacteriostat to effectively reduce the
growth of bacteria on the filter media. Not Performance Tested or
Certified by NSF.
HEALTH CLAIM PERFORMANCE CERTIFIED BY NSF/ANSI*
This system has been tested according to NSF/ANSI 42 and 53 for the
reduction of the substances listed below. The concentration of the
indicated substances in water entering the system was reduced to
a concentration less than or equal to the permissible limit for water
leaving the system, as specified in NSF/ANSI 42 and 53.
Influent Challenge
Max. Permissable Product
Substance
Concentration
Water Concentration
Standard 42—Aesthetic Effects
Chlorine
2.0 mg/L ± 10%
Particulate,
Class I
at least 10,000
particles 0.5
particles/mL
to <1 µm
Standard 53—Health Effects
Turbidity
11 ± 1 NTU
10
to 10
fibers/L > 10
7
8
Asbestos
micrometers in length
Cyst
Minimum 50,000/L
* Tested using flow rate = 1.67 gpm; pressure = 60 psig; pH = 7.5 ± 1;
temp. = 20° ± 3°C
† NTU = Nephelometric Turbidity Units
GENERAL INSTALLATION/OPERATION/MAINTENANCE
REQUIREMENTS
• Install vertically with cartridge hanging down
• Use minimum length of tubing possible
• Flush to drain for 5 minutes at full flow
• Replace cartridges when capacity is reached or when flow
becomes too slow, but at least annually.
Buyer
©2005 Everpure, LLC
MH AND MH
Reduction
Minimum
Requirements
Reduction
≥ 50%
≥ 85%
0.5 NTU
95.4%
99%
99.87%
99.95%
99.99%
Seller
WATER FILTERS
2
OPERATING SPECIFICATIONS
• Pressure requirement: 10-125 psi (0.7-8.6 bar), non-shock
• Temperature: 35-100° F (2-38° C)
NSF Listed Systems
QC7I Single - MH
QC7I Single - MH
2
QC7I Twin - MH
QC7I Twin - MH
2
QC7I Triple - MH
QC7I Triple - MH
2
QC7I Quad - MH
QC7I Quad - MH
2
* Includes 2
" clearance under unit for cartridge change
1
2
SPECIAL NOTICES
• Installation instructions, parts and service availability, and
standard warranty are included with the product when shipped.
• This drinking water system must be maintained according to
manufacturer's instructions, including replacement of filter
cartridges.
• Do not use with water that is microbiologically unsafe, or of
unknown quality without adequate disinfection before or after
the system. Systems certified for cyst reduction may be used on
disinfected waters that may contain filterable cysts.
• The contaminants or other substances removed or reduced by
this water treatment system are not necessarily in your water.
• Check for compliance with state and local laws and regulations.
Average
• Tested under standard laboratory conditions as specified above.
Reduction
Actual performance may vary depending on influent water
87.8%
conditions.
• To determine NSF Model Name, combine HEAD NAME +
CARTRIDGE NAME. Refer to www.nsf.org to verify certification.
99.2%
97.2%
System Tested and Certified by NSF International against
NSF/ANSI Standards 42 and 53 for the reduction of:
99.87%
Standard No. 42 —
Aesthetic Effects
99.99%
Chemical Reduction
Mechanical Filtration
Standard No. 53 —
Health Effects
Mechanical Filtration
PERFORMANCE

DATA SHEET

Max. Flow Rate
Capacity
1.67 gpm (6.3 lpm)
9,000 gal (34,050 L)
1.67 gpm (6.3 lpm)
9,000 gal (34,050 L)
3.3 gpm (12.6 lpm)
18,000 gal (68,100 L)
3.3 gpm (12.6 lpm)
18,000 gal (68,100 L)
5.0 gpm (18.9 lpm)
27,000 gal (102,150 L)
5.0 gpm (18.9 lpm)
27,000 gal (102,150 L)
6.6 gpm (25.3 lpm)
36,000 gal (136,200 L)
6.6 gpm (25.3 lpm)
36,000 gal (136,200 L)
Taste and Odor
Chlorine
Particulate Class I: 99.2% reduction of particles
one-half micron and larger in size
Turbidity
Cyst
Asbestos
Space Requirements*
29" H x 5
" W x 5" D
1
2
29" H x 5
" W x 5" D
1
2
25" H x 11" W x 5" D
25" H x 11" W x 5" D
25" H x 15" W x 5" D
25" H x 15" W x 5" D
29" H x 24" W x 5" D
29" H x 24" W x 5" D
Date
EV7013-18B OC05

Advertisement

loading

This manual is also suitable for:

Ev9613-06Ev9613-21Ev9613-26