ENGINE FAILS TO START OR STARTS WITH DIFFICULTY
CAUSE
REMEDY
Controls not in start position.
Spark plug wire disconnected
from spark plug.
Spark plug fouled.
Spark plug porcelain cracked.
Insufficient fuel.
i,,
Water or dirt in fuel.
Improper carburetor adjustment
ENGINE LACKS POWER
CAUSE
Dirty air cleaner.
Improper carburetor adjustment.
Lack of lubricaiton.
ENGINE MISSES UNDER LOAD
CAUSE
Spark plug fouled.
Spark plug porcelain cracked.
Improper spark plug gap.
Improper carburetor adjustment
Move ENGINE CONTROL or equipment control to "HI" or
START postion.
See "STARTING"
instructions in this
manual.
Connect SPARK PLUG WIRE to SPARK PLUG
Remove SPARK PLUG and clean it. See "SPARK
PLUG" instructions
in "MAINTENANCE"
section in this
manual.
Install new spark plug.
Fill FUEL TANK per "BEFORE STARTING" instructions.
Drain FUEL TANK and re-fill with clean, fresh gasoline.
See "BEFORE STARTING"
instructions
in this manual.
Adjust carburetor
(if applicable).
See "ADJUSTMENTS"
section in this manual.
REMEDY
Replace or clean air cleaner per "AIR CLEANER"
instructions in "MAINTENANCE"
section in this manual.
Adjust carburetor
(if applicable).
See "ADJUSTMENTS"
section in this manual.
Fill oil sump to proper level. See "BEFORE STARTING"
instructions
section in this manual.
REMEDY
Remove SPARK PLUG and clean it. See "SPARK
PLUG" instructions
in "MAINTENANCE"
section in this
manual.
Install new SPARK PLUG.
Regap SPARK PLUG electrodes.
See "SPARK PLUG"
instructions
in "MAINTENANCE"
section in this manual.
Adjust carburetor
(if applicable).
See "ADJUSTMENTS"
section in this manual.