Clearance
requirements,
continued
Installation
in a Recess or Closet
1
A dryer installed in a bedroom, bathroom, recess or
closet, MUST be exhausted outdoors.
2
No other fuel burning appliance shall be installed in
the same closet as the gas dryer.
3
Your dryer needs the space around it for proper
ventilation.
DO NOT install your dryer in a closet with a solid door.
4
Closet door ventilation
required: A minimum
of 120 square inches (774.2 cm 2) of opening,
equally divided at the top and bottom of the
door, is required. Openings should be located 3
inches (7.6 cm) from bottom and top of door.
Openings are required to be unobstructed when a
door is installed. A Iouvered door with equivalent
air openings for the full length of the door is
acceptable.
3"
(7.6c m]
closet door
-1--
60 sq.
in.
(387.1cm
2)
f
60 sq. in.
(387.1cm
2)
MINIMUM INSTALLATION CLEARANCES- Inches (cm)
SIDES
REAR
TOP
FRONT
Alcove
0" (0 cm) 3" (0 cm)* 0" (0 cm)
n/a
Under-
0" (0 cm) 3" (0 cm)* 0" (0 cm)
n/a
Counter
Closet
0" (0 cm) 3" (0 cm)* 0" (0 cm)
1" (2.54 cm)
For other
than straight
back venting,
a quick-turn
90 ° dryer vent elbow
(vented
right
or down
in free-
standing
dryer
or right
on pedestal-mounted
dryer)
must
be installed
to achieve
0" (0 cm) installation.
To achieve an installation with 0" (0 cm) clearance
for the back of the dryer (for other than straight back
venting), a quick-turn 90 ° dryer vent elbow must be
installed as described previously in this manual.