TECHNICAL
SPECIFICATIONS
FG7T (A and K Series)
Smartlite
,
Two Stage, Fixed Speed,
High Efficiency Upflow/Horizontal
and Downflow Gas Furnaces
Induced Draft - 80 + AFUE
Input 60,000 - 140,000 Btuh
The high efficiency gas furnace may be installed free
standing in a utility room, basement, or enclosed in an
alcove or closet. The rounded corner jacket provides a
pleasing "appliance appearance." Design certified by CSA
for application in Canada and the United States.
WARRANTY
– 10 Year all-parts warranty.
– 10 Year Quality Pledge to replace the unit if the heat
exchanger fails within the first 10 years of operation, to
the original owner.
– Consumer product registration required for 10 year
All Parts Warranty and Quality Pledge within a limited
period of time after the installation. See current warranty
document or visit our consumer web site for warranty
details.
– When registered, this product is upgraded to a limited
lifetime heat exchanger warranty.
®
FEATURES and BENEFITS
• i SEER: Energy efficient brushless DC (ECM) motor
gives up to 1 SEER point efficiency gain in cooling.
• 100% fired and tested: All units and each component
are tested on the manufacturing line.
• Best packaging in the industry: Unique corner post
design assures product will arrive to the homeowner dent
free.
• Low Boy Height: Easy to apply in low ceiling applications,
works well with taller high SEER coils, easier to handle
and install.
• Tubular primary heat exchanger: Heavy gauge
aluminized steel heat exchanger assures a long life.
• 30 second blower delay at start-up: Assures a warm
duct temperature at furnace start-up. Adjustable blower
off settings (60, 90, 120 and 180 seconds).
• 30 second post purge: Increases life of heat
exchanger.
• Hot surface igniter: Innovative application of a silicon
nitride igniter. Utilizes proven Smartlite
• Color coded wire harness: Designed to fit the
components, all with quick-connect fittings for ease of
service and replacement.
• High static blowers: All models equipped with high static
blowers.
• 90 second cooling cycle blower-off delay (TDR):
Increases cooling performance when matched with a
NORDYNE coil.
• Flexible category I venting system: May be vented
with dedicated venting system or common vented with
other category one appliances.
• Variable speed blower kit: Upgradable to full variable
speed with kit.
• LP convertible: Simple burner orifice and regulator spring
change for ease of convertibility.
• Diagnostic lights for easy troubleshooting without
counting flashes: Dedicated light for flame signal
strength and 2 lights in combination to indicate all other
fault codes with easy to recognize states without counting
flashes.
• Integrated control board: Incorporates connections for
electronic air cleaner, humidifier and twinning.
• Two piece door design: Enhances furnace appearance
and uses captured screws to prevent loosing door
screws.
• Blower Compartment: Insulated for ultra quiet
operation.
• 2 Stage Inducer: Optimizes efficiency on first stage heat
and reduces sound levels.
technology.
®