HP Surestore E Disk System FC10 Service Manual page 102

Hewlett-packard hp surestore e disk system fc10 user and service guide
Hide thumbs Also See for Surestore E Disk System FC10:
Table of Contents

Advertisement

Problem
HWEvent
Description
Category
Temperature
Critical
is over limit
Major
Warning
Temperature
Critical
is under limit
Major
Warning
Voltage is
Critical
over limit
Major
Warning
Voltage is
Critical
under limit
Major
Warning
102
Status
LED
State
SAM
none
none
Critical
Temp is
>54.5º C
none
none
Non-
critical
Temp is
>36º C
none
none
Critical
Temps
<9.5º C
none
none
Non-
critical
Temps
<15.5º C
none
none
Critical
none
none
Non-
critical
none
none
Critical
none
none
Non-
critical
STM
Probable Cause/Solution
– A fan is faulty. Check status and
correct.
– Airflow is obstructed; vents are
blocked.
– One or more slots are empty.
– Power supply is faulty. Check status
and correct.
– Room temperature is too high. If
ambient temperature cannot be
reduced in a reasonable time, turn
off product to prevent shortened life.
– Temperature sensor is faulty.
Compare temperature reported by
peer LCC.
– Room temperature is too low.
– Temperature sensor is faulty.
Compare temperature reported by
peer LCC.
Power supply is faulty. Check status
and correct.
Either power supply is faulty. Check
status and correct.