Rigid Pipe Venting; Dura-Vent Horizontal Installation; Dura-Vent Vertical Termination Installation; Horizontal Terminations - Waterford TARA T25-LP Owners & Installation Manual

Direct vent freestanding gas stove
Table of Contents

Advertisement

INSTALLATION

RIGID PIPE VENTING -

HORIZONTAL TERMINATIONS

The shaded area in the diagram below shows all allowable combinations
of vertical runs with horizontal terminations. Maximum one 90
o
o
(two 45
elbows equal one 90
Residential and Manufactured Homes /
Mobile Homes Installations
The venting arrangements diagrammed below, have a minimum of 75% (flue loss)
efficiency with Fan Off, as required for manufactured homes. (Actual efficiency
may be as high as 85%.)
RIGID PIPE VENTING - VERTICAL TERMINATIONS
The shaded areas in the two diagrams below show all allowable combinations of straight vertical and offset to vertical runs with
vertical terminations. Maximum two 45
vent installations require Vent Restrictor #1. If the vent is ENCLOSED in a chase (min. size 9" x 9") maintain a 1-1/4" clearance to combustibles.
Straight Vertical
Terminations
18
elbow) using Dura-Vent Venting Systems
for both Residential & Manufactured Homes/Mobile Homes
o
elbows (not including the 45
Vent Restrictor must be set at 5/8" for this venting installation.
O
elbow
o
elbow attached to the unit.). All vertical and offset to vertical
Offset to Vertical Terminations
Waterford TARA T25 Direct Vent Freestanding Gas Stove