INSTALLATION

You will require the following components with
your new Emerald Direct Vent Freestanding
Gas Stove. Please review your product to
make sure you have everything you need. In
the event that you are missing any part, contact
your dealer.
Note: These are the minimum pieces
required. Other parts may be re-
quired for your particular installa-
tion. See page 17 for a list of vent
parts.
The FPI AstroCap
TM
and FPI Riser Vent terminal is certified for installations using FPI venting
systems as well as Simpson Dura-Vent®, Direct Vent GS, American Metal Products, Ameri
Vent Direct vent and Selkirk Direct-Temp. FPI
trademarks of FPI Fireplace Products International Ltd. Dura-Vent® and Direct Vent GS are
registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc.
18
If installing termination on a siding covered wall,
a vinyl siding standoff or furring strips can be
used in order to ensure that the termination is
not recessed into siding.
The vinyl siding standoff is required for walls
with vinyl siding.
Dura-Vent Basic
Horizontal Kit # 970
1 90
o
Elbow
1 Wall Thimble Cover
1 Horiz. Sq. Term. Cap
When using piping other than Simpson
Dura-Vent, 3 screws must be used to
secure rigid pipe to adaptor.
TM
, and FPI AstroCap
TM
are the proprietary
Minimum components for a Dura-Vent
Horizontal Installation:
A) Dura-Vent Horizontal Termination Kit
B) Wall Thimble (required for combustible walls)
Minimum components for a Dura-Vent
Vertical Termination:
D) Dura-Vent Vertical Termination Kit. See
page 17 for pipe lengths.
WARNING:
Do not combine venting components from
different venting systems.
However use of the the AstroCap
Riser is acceptable with all systems.
This product has been evaluated by Intertek for
using a Dura-Vent Flue Adaptor in conjunction
with Selkirk Direct-Temp and Ameri Vent Direct
venting systems. Use of these systems with
the Direct Vent GS starting collar is deemed
acceptable and does not affect the Intertek WHI
listing of components.