Mobile Home Installation; Minimum Clearances To Combustible Materials - Waterford Trinity Mk II Installation & Operating Instructions Manual

Woodburning stove
Hide thumbs Also See for Trinity Mk II:
Table of Contents

Advertisement

To connect this stove to an outside air supply use
either 4" (100mm) rigid of flexible stainless steel
pipes
or
non-combustible
materials not more than 54" (1370mm) in length and
having no sharp bends or corners other than the
down turn at the terminus. The outside air inlet
terminus must be fitted with a
corrosion-resistant wire mesh to prevent leaves, and
rodents entering from the outside.
Air inlets traversing cavity walls should include a
continuous duct across the cavity. The duct should
be installed in such a manner as not to impair the
weather resistance of the cavity.
Joints between air vents and outside walls should be
sealed to prevent ingress of moisture.
Fig.14

MOBILE HOME INSTALLATION

In addition to standard installation instructions the
following requirements are mandatory for installation
in a mobile home.
CAUTION: Do not obstruct combustion air opening.
1. The stove must be permanently bolted to the
floor of the Mobile Home using the floor screws
provided.
2. The stove must have a permanent outside air
source for combustion.
3. The stove must be grounded to the steel chassis
of the Mobile Home.
4. A listed chimney system, roof thimble, spark
arrestor and roof flashing kit suitable for use in
Mobile Homes must be used.
5. If the chimney exits the Mobile Home at a
location other than through the roof, and exits at
a point 7 ft. (2100mm) or less above the ground
level on which the Mobile Home is positioned, a
guard or method of enclosing the chimney shall
be fitted at the point of exit for a height up to 7 ft.
(2100mm).
6. The chimney shall be attached directly to the
room heater and shall extend at least 3 ft.
(910mm) above the part of the roof through
which it passes. The top of the chimney should
project at least 2 ft. (610mm) above the highest
corrosion-resistant
/
" (6mm) x
/
" (6mm)
1
1
4
4
Air Duct
Wire Mesh
elevation of any part of the Mobile Home within
10 ft. (3040mm) of the chimney.
7. The chimney systems shall comply with the
standard for
dential Type and Building Heating Appliances UL
103.
8. Any openings in a chimney guard if used must
not permit the entrance of
rod.
9. CAUTION:
THE STRUCTURAL INTEGRITY
OF THE MOBILE HOME ROOF, FLOOR,
WALLS
AND
MAINTAINED.
10. Check any other local building code as other
local codes may apply.
11. WARNING: DO NOT INSTALL IN A
SLEEPING ROOM.
NOTE:
Listed factory built chimney connectors
including elbows are acceptable for use in Mobile
Home Installations.
MINIMUM CLEARANCES TO COMBUSTIBLE
MATERIALS
From the front of stove
From the side of stove
From corner installation
From back of stove
horizontal installation only
If the side door is to be used the right hand side
clearances when looking from the front of the stove must
be increased to
Mantle clearance
30"Trim Clearance
Vertical Single Wall Flue Pipe (USA)
Vertical Single Wall Flue Pipe (Canada)
USA from back of stove
Canada from back of stove
This stove has been tested in a combustible alcove
measuring 84" high x 72" wide x 48" deep.
5
Chimneys Factory - Built Resi-
3
/
" (19mm) diameter
4
CEILING
MUST
48" (1220mm)
22" (560mm)
14" (355mm)
8" (200mm)
48" (1220mm)
22" (560mm)
14" (355mm)
18" (460mm)
15" (380mm)
19" (480mm)
BE

Hide quick links: