In The Event Of A Chimney Fire; Fire Safety - Waterford Fionn 90 O.S.A. Installation And Operating Instructions Manual

Woodburning stove
Table of Contents

Advertisement

WARNING: USE ONLY CERAMIC GLASS 5mm
THICK. ABUSE SUCH AS STRIKING, SLAMMING
AND
USE
OF
SUBSTITUTE
SHOULD BE AVOIDED.

FIRE SAFETY

To provide reasonable fire safety, the following
should be given serious consideration:
1.
The installation of smoke detectors.
2.
A conveniently located Class A fire extin-
guisher to contend with small fires resulting
from burning embers.
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS:
SIDE WALL TO STOVE........................................................................................20 INCHES - 510mm
BACK WALL TO CHIMNEY CONNECTOR..........................................................18 INCHES - 460mm
BACK WALL TO STOVE TOP & REAR EXIT.................................................14
CEILING TO HORIZONTAL CONNECTOR..........................................................18 INCHES - 460mm
CORNER................................................................................................................13 INCHES - 330mm
MANTLE CLEARANCE..........................................................................................25 INCHES - 635mm
SIDE TRIM..............................................................................................................14 INCHES - 355mm
When installing this heater on a combustible floor, a floor protector consisting of a layer of non-combustible
material at least 3/8" thick or 1/4" thick covered with 1/8" sheet of metal is required to cover the area under the
heater to extend at least 18" at the front and 8" to the sides and back of stove. This will provide protection from
sparks and ember which may fall out from the door when stoking or refuelling.
3.
4.
MAT E R I A L S

IN THE EVENT OF A CHIMNEY FIRE

(a)
(b)
(c)
(d)
FIONN 90 O.S.A.
FLOOR PROTECTION
Waterford Stanley Ltd.,
Bilberry, Waterford, Ireland.
Tel: 051-302300
Fax: 051-302375
12
A practiced evacuation plan.
A plan to deal with a chimney fire as follows:
Notify the fire department.
Prepare occupants for immediate evacuation
Close all openings into the stove.
While awaiting fire department watch for igni-
tion to adjacent combustibles from over
heated stove pipe or hot embers or sparks
from the chimney.
" INCHES - 370mm
1/2
Rev: 003: DP020703