Download Print this page

Vermont Castings 20011992 Installation Instructions page 3

Fuel conversion kit for models: dvt38in, dvt44in, dvt38s2in

Advertisement

Pilot Adjustment Screw
Gas Type
Marker
CO137
Fig. 7 Remove black plastic cap and adjust rotary knob to
correct gas type. (LP position shown) Replace minimum rate
screw with one supplied in conversion kit.
13. Reinstall burner to original position. Reinstall burner
leg, burner tube and fettle. Re-attach supply tube to
gas supply fitting. Using a back-up wrench, tighten
securely.
14. Test for leaks. Apply electric and gas to the system.
�����
15. Light the pilot burner using the remote control. With
soapy solution check for leaks around the pilot as-
������ ����� ����������
sembly where the tube enters the pilot assembly.
Tighten fitting if necessary.
����
16. Light the main burner and check for leaks around
the burner supply tube fittings and burner orifices.
Tighten if necessary.
17. Turn fireplace OFF.
18. After the conversion and leak checks have been
made, manifold outlet pressure can be checked
with a manometer at the test ports located at the
side front edge of the fireplace opening. The lower
test port is manifold outlet pressure.
CAUTION: Turn off the gas supply before
removing test port plug.
19. Using a 7/16" nut driver, remove the threaded plug
20. Thread the supplied extension adaptor into the
21. Attach a 1/4" diameter pressure gauge flexible hose
22. Turn on gas supply and operate valve with remote
23. After test, remove adaptor and replace plug.
24. Turn on gas supply and check that plugs are tight
Minimum Rate
Screw
25. Follow instructions in Homeowner's Manual to
26. Replace glass frame.
27. Conversion complete.
Pilot Flame Adjustment
Typically, the top 3/8" or 1/2" of the thermopile should
be engulfed in the pilot flame. (Fig. 8)
To adjust pilot burner: Adjust pilot screw on valve to
provide properly sized flame..
Fig. 8 Correct pilot flame appearance.
from the test port.
open test port.
fully onto the barb of the adaptor.
control as needed to indicate gas pressure. The
manifold pressure for LP should be approximately
10.0" wcp.
CAUTION: Turn off the valve and gas supply
before removing test port adaptor and replac-
ing plug.
and leak free.
re-assemble brick panels, logs, lava rock, volcanic
rock, embers and andirons.
FP1229a