GarrettCom Magnum IPS42 Installation And User Manual

Internal power supply for edge switch family

Advertisement

Quick Links

Magnum IPS42 Internal Power Supply
for Edge Switch Family
Installation and User Guide
www GarrettCom com
.
.
$5.00 USD

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Magnum IPS42 and is the answer not in the manual?

Questions and answers

Summary of Contents for GarrettCom Magnum IPS42

  • Page 1 Magnum IPS42 Internal Power Supply for Edge Switch Family Installation and User Guide www GarrettCom com $5.00 USD...
  • Page 2 Installation and User Guide Part #: 84-00181Z Rev. B Trademarks GarrettCom is a registered trademark and Magnum, Dymec, DynaStar, Personal Switch, Link-Loss-Learn, S-Ring, Convenient Switch and Converter Switch are trademarks of GarrettCom, Inc. Ethernet is a trademark of Xerox Corporation...
  • Page 3 If problems are experienced with Magnum IPS42 Internal Power Supply products, consult Section 4, Troubleshooting, of this User Guide. Copyright © 2009 GarrettCom, Inc. All rights reserved. No part of this publication may be reproduced without prior written permission from GarrettCom, Inc.
  • Page 4 Operation of this equipment in a residential area is likely to cause interference, in which case the user, at his own expense, will be required to take whatever measures may be required to correct the interference. www GarrettCom com...
  • Page 5 Class 2, or listed ITE Power Supply, marked LPS, which has suitably rated output voltage (i.e. 24VDC or 48VDC) and suitable rated output current. Product does not contain user replaceable fuses. Any internal fuses can ONLY be replaced by GarrettCom personnel through the RMA process. www GarrettCom com...
  • Page 6 IPS42 Internal Power Supply Installation and User Guide (11/09) Contacting GarrettCom, Inc Please use the mailing address, phone, fax numbers and email address listed below: GarrettCom, Inc. 47823 Westinghouse Dr. Fremont, CA 94539 Phone (510) 438-9071 Fax (510) 438-9072 Website: http://www.GarrettCom.com...
  • Page 7: Table Of Contents

    Mounting Dimensions for IPS42 with metal brackets ....12     3.1.2 DIN-Rail mounting option ............15     Power Cord Installation ..............16     Hardware operated Alarm Contact ............ 20     TROUBLESHOOTING ..............21     Before Calling for Assistance ............22 www GarrettCom com...
  • Page 8 Return Material Authorization (RMA) Procedure ......25     Shipping and Packaging Information ..........26   APPENDIX A: WARRANTY INFORMATION ......... 28 Revisions Rev. B 11/09: Updated DIN Rail mount photo (Sec. 3.1.2) Rev. A 07/09: Initial Release www GarrettCom com...
  • Page 9: Specifications

    24VDC: Input 20 to 36VDC Surge Rating: IEC 61000-4-3, Class 3/4 (4KV for DC) Std. Terminal Block for DualSRC: A: “-, GND, +”, B: “-, GND, +” Power Consumption: 10 Watts typical for a 4+2 port fiber model www GarrettCom com...
  • Page 10: Mechanical Specifications

    IEC 60068 “Type Test” exceeds -40° to 185°F (-40° to 85°C) Storage: -60° to 212°F (-50° to 100°C) Relative Humidity: 5% to 95% (non-condensing) Altitude: -200 to 13000FT (-60 to 4000M) UL 60950 “Component Parts” rating: -40° to 140°F (-40° to 60°C) Conformal coating (humidity protection): optional www GarrettCom com...
  • Page 11 Internal 60VA relay contact: Open for power Off, closed for power On (Hardware). Mounting options Metal mounting clips for panel mounting: included DIN-Rail mounting option: Model # DIN-RAIL-MC2 (see Section 3.1) Mean Time Between Failure (MTBF) 15 years, Telcordia (Bellcore) Method – over www GarrettCom com...
  • Page 12 IEC 61850 EMC and Operating Conditions Class C Power Substations IEEE 1613 Env. Standard for Electrical Power Substations NEBS L3 and ETSI compliant including vibration, shock and altitude NEMA TS-2 and TEES for traffic control equipment Warranty: Three years, return to factory Made in USA www GarrettCom com...
  • Page 13: Summary Of Models And Descriptions For Ips42 Series

    ES42H or ES42P Series Edge Switch. Requires simultaneous ordering of an ES42 (without external power supply) as a separate line item. Rated 100 to 250 VDC, Dual Source. Power input via recessed terminal block, UL Listed and Surge protected. www GarrettCom com...
  • Page 14 ES42H or ES42P Series Edge Switch. Requires simultaneous ordering of an ES42 (without external power supply) as a separate line item. Rated 20 to 36 VDC, Dual Source. Power input via recessed terminal block, UL Listed and Surge protected. IPS42-xxVDC-DualSRC www GarrettCom com...
  • Page 15 Standard worldwide AC power input via standard IEC320 recessed male connector, UL Listed and Surge protected. IPS42-AC Accessories DIN-RAIL-MC2 = Metal DIN-Rail mounting bracket for one IPS42 Series product (see Section 3.1) Conformal Coating (for high humidity and “tropical” applications) - request quote. www GarrettCom com...
  • Page 16: Introduction

    This package should contain: Magnum IPS42 Series Internal Power Supply for Edge Switch 1 set Metal panel mounting clips and screws (4 each) Power Cord Installation Kit (if applicable) IPS42 User Guide (this manual) ES42 User Guide www GarrettCom com...
  • Page 17: Product Description

    DC power inputs and provide high availability. Any one of the models of the ES42s may be ordered concurrently with any of the five IPS42 models. Note: See ES42 User Guide for specifications related to the ES42 Series of Edge Switch. www GarrettCom com...
  • Page 18: Features And Benefits

    Worldwide AC power input with standard IEC 320 recessed male power plug Rugged metal case, Industrial grade IPS42 Series have a robust design and are packaged in a rugged sheet metal enclosure to ensure high reliability and durability even when placed in industrial or outdoor applications. www GarrettCom com...
  • Page 19: Installation

    A Velcro strip may be used for mounting the unit on a vertical surface such as a wall or cabinet, or for securing the unit on a table-top or shelf. Alternatively, metal mounting clips and screws are included for a rugged and secure mounting in any orientation. www GarrettCom com...
  • Page 20: Mounting Dimensions For Ips42 With Metal Brackets

    It is recommended to mount the units vertically (see page 14) for proper cooling and long-life reliability. It is also advisable to mount the unit with space for air movement around the top and the sides, typically a minimum of 1 inch. www GarrettCom com...
  • Page 21 Since the IPS42 Series has special internal thermal techniques (patent pending) to move the heat generated by the electronic components inside into the case, the case may be quite warm to the touch during normal operation. www GarrettCom com...
  • Page 22 The unit is mounted using the brackets as shown in the illustration above. The spacing for the mounting screws into the supporting wall or panel is a rectangle 15.49 x 12.89 cm (6.10 x 5.075 inches) center-to-center. www GarrettCom com...
  • Page 23: Din-Rail Mounting Option

    A Magnum IPS42 is shown with the DIN-RAIL-MC2 bracket installed The metal DIN-Rail mounting hardware is optional and needs to be ordered as a separate item, e.g. Model #DIN-RAIL-MC2. It comes with four screws to attach the bracket to the MC unit. www GarrettCom com...
  • Page 24: Power Cord Installation

    The units are provided with a 4-position screw- lock terminal block for installing the power cord. (shown in fig. 3.2a) www GarrettCom com...
  • Page 25 Note: The 4-position terminal block accepts 28-16 AWG wire. Strip the wire ends of the power cord and place into the appropriate hole in the terminal block (see Fig. 3.2c). Tighten the locking screws to secure. www GarrettCom com...
  • Page 26 Secure the assembled terminal block to the mating piece of the unit. (see Fig. 3.2d) Secure the assembled power cord cover to the IPS42 case. (see Fig. 3.2e) Attach a Safety Ground to the Grounding post of the IPS42 case. (see Fig. 3.2a) www GarrettCom com...
  • Page 27 IPS42 Internal Power Supply Installation and User Guide (11/09) BLUE or WHITE (-) (GND) www GarrettCom com...
  • Page 28: Hardware Operated Alarm Contact

    IPS42. This provides a “Hardware operated Alarm” because the NC contacts will open when internal power is lost, either from an external power down condition or by the failure of the power supply inside of the Magnum IPS42-Series Power Supply. www GarrettCom com...
  • Page 29: Troubleshooting

    Magnum IPS42 Series Internal Power Supply is not performing as expected, do not attempt to repair the unit; instead contact your supplier for assistance or contact GarrettCom Customer Support. www GarrettCom com...
  • Page 30: Before Calling For Assistance

    Loop test to test the fiber transceiver is functional or not. Use a short patch cable of fiber and connect one end of cable to transmit and other end of receive to the fiber port transceiver. If the Link Led turns solid green, then the fiber port is functional and working. www GarrettCom com...
  • Page 31 If the problem continues after completing Step 5 above, contact your supplier of the Magnum IPS42 Series unit or if unknown, contact GarrettCom, Inc. by fax, phone or email - (support@garrettcom.com) for assistance www GarrettCom com...
  • Page 32: When Calling For Assistance

    The components/devices involved in the problem; d. Any particular application that, when used, appears to create the problem; An accurate list of GarrettCom product model(s) involved, with serial number(s). Include the date(s) that you purchased the products from your supplier.
  • Page 33: Return Material Authorization (Rma) Procedure

    Name and phone number of your contact person. Name of your company / institution Your shipping address Product name Serial Number (or Invoice Number) Packing List Number (or Sales Order Number) Date of installation Failure symptoms (including a full description of the problem) www GarrettCom com...
  • Page 34: Shipping And Packaging Information

    (user) charge. 4.4 Shipping and Packaging Information Should you need to ship the unit back to GarrettCom, please follow these instructions: Package the unit carefully. It is recommended that you use the original container if available. Units should be wrapped in a "bubble-wrap" plastic sheet or bag for shipping protection.
  • Page 35 This material may cause electro-static shock damage to the unit. Clearly mark the Return Material Authorization (RMA) number on the outside of the shipping container. GarrettCom is not responsible for your return shipping charges. Ship the package to: GarrettCom, Inc.
  • Page 36: Appendix A: Warranty Information

    GarrettCom, Inc. warrants its products to be free from defects in materials and workmanship for a period of three (3) years from the date of shipment by GarrettCom. During this warranty period, GarrettCom will repair or, at its option, replace components in the products that prove to be defective at no charge other than shipping and handling, provided that the product is returned pre-paid to GarrettCom.

Table of Contents