2.3 Mounting the EMS100

Attach the Maretron EMS100 securely to the vessel using bolts or screws (not included) as
shown in Figure 1 below.
Figure 1 – Mounting the EMS100

2.4 Connecting the EMS100

You connect the EMS100 using a Maretron wiring harness (available separately) which is
designed for a particular type of engine. One end of the Maretron wiring harness has two 12-
pin Deutsch connectors which plug into the two connectors on the end of the EMS100 product
enclosure. These connectors are keyed differently, so there is no danger of plugging these in
incorrectly.
®
2.4.1 Connecting to NMEA 2000
Interface
®
The Maretron EMS100 provides a connection to an NMEA 2000
interface through a five pin
male connector located on the Maretron wiring harness, which is purchased separately (see
Revision 1.1