TereScope700 and TereScope800 Wireless Optical Communication Links Models TS700/100, TS700/155, TS700/G, TS800/155 User Manual...
Page 2
W I R E L E S S O P T I C A L C O M M U N I C A T I O N S User Manual Document Number ML48237 (4703700), Rev. 4.0 February 2006 MRV Communications, Inc. Web site: www. mrv.com...
M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l Table of Contents S T A N D A R D S Standards Compliance ................
Page 4
M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l Data/Signal Cabling ................
M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l About this User Manual Audience This manual is intended for the user who wishes to install, operate, manage and...
M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l Safety Requirements All requirements stipulated in the safety laws of the country of installation must be abided by when installing the TereScopes.
M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l 2.
Page 14
M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l B a c k P a n e l D e s c r i p t i o n Table 2: TS700/155 Standard Model Back Panel Controls, Interfaces, and Indicators Connectors...
M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l B.
Page 16
M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l Selectors Data Rate Set the transmission rate of the transceiver (internal...
Page 17
M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l Indicators Air RX Flag LED Green LED indicates data received by the Airlink...
M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l C.
Page 19
M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l That’s what happens when the air channel...
Page 20
M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l Fusion Maximizing Link Availability in All Weather Conditions.
M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l E.
Page 24
M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l Selectors Transmitter Mode ON position (up) for links above 150m distance.
M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l Typical Connection 1 - Fiber Connection In order to implement a connection, each transceiver must be connected to the...
M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l Chapter Site Survey The first step before every installation is to visit the sites to be linked.
Page 28
M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l In case such situations Prefer Avoid...
Page 29
M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l Figure 2.1: Optimal Mounting TereScope at edge of roof so that heat rising from roof...
M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l Figure 2.4 shows an unacceptable TereScope link location because of interference by passing vehicles.
Page 31
M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l Note: If the only option to mount the TereScope is at points 5, 6 or 7, it has to be mounted at least 2 m above the rooftop to avoid roof scintillations and people crossing the link beam (If possible, avoid placing the TereScope on a mast).
M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l Figure 2.8: Wall Mounting (using JMP and JMB) Figure 2.9: Wall Pedestal Mounting (using JMP and MO54C)
Page 33
M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l Figure 2.12 shows the arrangement for transmitting through a window Figure 2.12: Arrangement for transmitting through a window.
M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l Chapter Infrastructure The only infrastructure required for operating the transceiver and linking...
M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l A simple power loss test can inform us about the condition of the fibers.
M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l Chapter Bench Test It is always easier and more convenient to locate a failure and solve a...
M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l Configuration 3: (Applicable to all models) Loop-back Airlink BER test...
M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l Chapter Installation This chapter shows how to mount the TereScope and and accessories...
Page 42
M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l H (x5) I (Axis) Aiming Head...
Page 43
M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l Alignment Kit Fig.
M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l The Installer Tool Kit (JITK-L) JITK: Installer Tool The JITK-L tool kit includes the work tools required for opening and closing...
M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l Figure 5.13b: JMP-L on the fixation surface THE JMP-L SHOULD BE ORIENTED IN SUCH A WAY THAT THE GROUNDING SCREW IS LOCATED ON THE BACK (CLOSE TO THE INSTALLER) AND THE FRONT FACING THE...
Page 47
M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l To use the floor, a very stable tower standing on the floor is required.
M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l Note The Tower Mount and the Clamping Plate are not provided with the equipment and should be supplied by the installer.
M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l Chapter Aiming Procedure Point to point connections require the orientation face to face of both “transceiving”...
M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l Transceiver Alignment General Point-to-point connections require face-to-face orientation of both...
M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l 2.
Page 52
M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l Fine Alignment Vertical Motion Screws –...
Page 53
M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l Repeat this process for the vertical positioning (middle of segment [V1,V2]).
M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l Link Operating Test Set back the Mode Select Dip-Switch on the Normal position (the Alignment indicator should switch OFF (if exists depending on the model)).
Page 55
M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l Fig.
M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l Product Specifications APPENDIX A 700/155...
Page 58
M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l TS700/100 (Fast-Ethernet Light) Part Number TS100/A/FET/VS...
Page 59
M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l TS800/155 (high speed Light) Part Number TS155/C2/YUW/VS or TS155/C2/YUW/FS...
Page 60
M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l TS700/G (Giga-Light) Part Number TS1000/A/YUW/VS...
M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l APPENDIX C Unpacking Instructions for TereScope The TereScope is shipped pre-assembled.
M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l Tool Kit, Equipment, and Materials APPENDIX D TOOLS...
Page 64
I n c . – I n s t a l l a t i o n M a n u a l A LIST OF THE TOOLS SUPPLIED BY MRV COMMUNICATIONS WITH EVERY TereScope HEAD Description Where to use...
Page 65
M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l TereScopes Bench Test Procedure APPENDIX E Introduction...
Page 66
M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l allows for testing each transmitter separately.
Page 67
M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l Figure E.2b: Bench Test setup drawing for 10”...
Page 69
M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l Effect of Wind on Terescopes APPENDIX F Introduction...
Page 70
M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l Appendix G FSO Chaining What is Chaining?
Page 71
M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l Indirect Chaining Indirect Chaining is required for connecting FSO units not including...
Page 72
M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l FSO products &...
Page 73
M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l Installation Log APPENDIX H D.1.
Page 74
M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l D.4.
Page 75
M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l D.5.
Page 76
M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l D.6.
Page 77
M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l APPENDIX I Power over Ethernet The Power-over-Ethernet (PoE) option is available only for Low Voltage TereScope model 700/100.
Need help?
Do you have a question about the TERESCOPE TS700/100 and is the answer not in the manual?
Questions and answers