Vantage Hearth VMH26TNC Owners Manual And Installation Manual page 12

Vent-free compact fireplace
Table of Contents

Advertisement

WARNING: Never modify or
cover the louvered slots on the
front of the firebox.
Mantel Clearances for Built-In
Installation
If placing mantel above built-in fireplace, you
must meet minimum clearance between man-
tel shelf and top of fireplace opening.
NOTICE: Surface temperatures
of adjacent walls and mantels be-
come hot during operation. Walls
and mantels above the firebox
may become hot to the touch.
If installed properly, these tem-
peratures meet the requirement
of the national product standard.
Follow all minimum clearances
shown in this manual.
NOTICE: If your installation does
not meet the minimum clear-
ances shown in Figure 11, you
must do one of the following:
• raise the mantel to an accept-
able height
• remove the mantel
10"
Note:
8"
All vertical
measurements
6"
are from top of
2
fireplace
opening to
bottom of
mantel shelf. All
measurements
are in inches.
Figure 11 - Minimum Mantel Clearances
for Built-In Installation
12
InsTallaTIon
Mantel Shelf
1
/
"
2
Side of
Firebox
www.fmiproducts.com
Continued
OPTIONAL MANTEL INSTALLATION
Refer to instructions provided with the mantel
for assembly instructions. Refer to the follow-
ing instructions for system installation. Refer
to instructions on page 6 for hood assembly.
Blower accessory should be installed prior
to mantel if it is being used (see Installing
Optional Blower Accessory GA3450TA,
page 13).
1. Assemble cabinet mantel as shown in
accessory instruction sheet.
2. If blower is installed, install a properly
grounded, 120 volt three-prong electrical
outlet at fireplace location if an outlet is not
there. If possible, locate outlet so cabinet
mantel will cover it when installed (see
Figure 12).
3. Place hearth base against wall at installa-
tion location. Cut an access hole in hearth
base to run gas line to fireplace (see Figure
12). Make sure to locate access hole so
cabinet mantel will cover it when installed.
Note: You can secure base to floor using
wood screws. Countersink screw heads
and putty over.
4. Route flexible gas line through access
hole in hearth base.
5. Center cabinet mantel on hearth base (see
Figure 13, page 13). Make sure mantel is
flush against wall and centered left to right
on base.
6. Use screws provided with mantel accessory
to attach mantel assembly to base (see
mantel instruction sheet).
7. Attach flexible gas line to fireplace gas
regulator. See Connecting to Gas Supply,
page 16.
8. Route electrical cord(s) through access
holes in either side of fireplace with bushing.
Plug electrical cord(s) into electrical outlet.
Hearth
Base
Figure 12 - Placing Hearth Base Against Wall
Pipe and Gas
Shutoff Valve
Electrical
Outlet
113111-01K

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vmh26tpc