CAUTION
The HRV and all condensate lines must be
installed in a space where the temperature is
maintained above the freezing point or freeze
protection must be provided.
CAUTION
Do not mount exhaust grille within 4'
(1.2m) (horizontally) of a stove to prevent
grease from entering the unit.
DRAIN HOSE PLUMBING
PRE-PUNCHED HOLES (2)
DRAIN PAN
DRAIN
SPOUT
ZIP TIE
HARD PIPE PLUMBING
PRE-PUNCHED HOLES (2)
DRAIN PAN
1/2" HARD PIPE
DRAIN
SPOUT
TEE
JOINT
Note: Secondary drain pan may be required to protect from
condensate leakage.
CAUTION
Drain trap and tubing MUST be below
bottom of door with 1/4" per foot
downwards slope away from unit.
DRAIN PAN
DRAIN
SPOUT
TEE
1/2 " I.D.
CONNECTOR
DRAIN HOSE
TO DRAIN
DRAIN PAN
DRAIN
SPOUT
TO DRAIN