PERFORMANCE D ATASHEETS
Base Grille Water
Filtration
System
Model T2WG2LfT2RFWG2
Capacity 200 Gallons (758 Liters)
Model T2WG2/T2RFWG2
Capacity 200 Gallons (758 Liters)
System
tested and certified
by NSF International
against
NSF/ANSI
Standard
42 for the reduction
of Chlorine
Taste and Odor, Particulate
Class II*; and against
NSF/ANSI
Standard
53 for the reduction
of Mercury,
Benzene,
Toxaphene,
O-dichlorobenzene,
and Carbofuran.
This system
has been tested according
to NSF/ANSl
Standards
42 and 53 for the reduction
of the substances
listed below. The
concentration
of the indicated
substances
in water entering
the system was reduced
to a concentration
less than or equal to the
permissible
limit for water leaving the system,
as specified
in NSF/ANSl
Standards
42 and 53.
Substance
Reduction
NSF Reduction
Average
Influent Challenge
Maximum
Average
Minimum %
Average %
Aesthetic
Effects
Requirements
Influent
Concentration
Effluent
Effluent
Reduction
Reduction
Chlorine Taste/Odor
50% reduction
2.0182 mg/L
2.0 mg/L _+10%
0.06 mg/L **
0.0536 mg/L
97.03
97.34
Particulate Class II*
85% reduction
1333333 #/mL
At east 10,000 part c es/mL 6600 #/mL
2325 #/mL
99.51
99.83
Contaminant
NSF Reduction
Average
Influent Challenge
Maximum
Average
Minimum %
Average %
Reduction
Requirements
Influent
Concentration
Effluent
Effluent
Reduction
Reduction
Lead: @ pH 6.5***
0.010 mg/L
0.1533 mg/L
0.15 mg/L _+10%
0.0005 mg/L
0.0005 mg/L
99.67
99.67
Lead: @ pH 8.5***
0.010 mg/L
0.1400 mg/L
0.15 mg/L _+10%
0.0007 mg/L
0.0006 mg/L
99.50
99.57
Mercury: @ pH 6.5
0.002 mg/L
0.0058 mg/L
0.006 mg/L _+10%
0.0002 mg/L
0.0002 mg/L
96.54
96.54
Mercury: @ pH 8.5
0.002 mg/L
0.0059 mg/L
0.006 mg/L _+10%
0.0005 mg/L
0.0003 mg/L
91.57
94.92
Benzene
0.005 mg/L
0.0154 mg/L
0.015 mg/L _+10%
0.0012 mg/L
0.0006 mg/L
92.22
96.34
O-Dichlorobenzene
0.6 mg/L
1.7571 mg/L
1.8 mg/L _+10%
0.0250 mg/L
0.0066 mg/L
98.58
99.63
Toxaphene
0.003 mg/L
0.015 mg/L
0.015 mg/L _+10%
0.001 mg/L
0.001 mg/L
93.33
93.33
Carbofuran
0.04 mg/L
0.0819 mg/L
0.08 mg/L _+10%
0.0400 mg/L
0.0213 mg/L
51.13
74.00
Test Parameters: pH = 7.5 _+0.5 unless otherwise noted. Flow = 0.85 gpm (3.2 Lpm). Pressure =
Temp. = 68°F to 71.6°F (20°C to 22°C).
It is essential that operational, maintenance, and filter
replacement requirements be carried out for the product to
perform as advertised.
Use replacement cartridge T2RFWG2, part #4396841.
In Canada, use replacement cartridge T2RFWG2, part
#4396841 B. 2008 suggested retail price of $39.99 U.S.A./
$49.99 Canada. Prices are subject to change without notice.
Model T2WG2L: Style 1 -When the filter indicator reads 10%,
order a new filter. When the filter indicator reads 0%, it is
recommended that you replace the filter.
Style 2 - When the filter indicator light changes from green to
yellow, order a new filter. When the filter indicator light changes
from yellow to red, it is recommended that you replace the filter.
Style 3 - When the water filter status display changes from
"GOOD" to "ORDER," order a new filter. When the filter
indicator reads "REPLACE," it is recommended
that you
replace the filter.
Model T2WG2: Change the water filter cartridge every
6 months depending upon your usage. If the water flow to the
water dispenser or ice maker decreases noticeably before
6 months have passed, replace the water filter cartridge more
often.
These contaminants
are not necessarily in your water supply.
While testing was performed under standard laboratory
conditions, actual performance may vary.
60 psig (413.7 kPa).
The product is for cold water use only.
Do not use with water that is microbiologically
unsafe or of
unknown quality without adequate disinfection before or after
the system.
Refer to the "Assistance or Service" section for the
Manufacturer's
name, address and telephone number.
Refer to the "Warranty" section for the Manufacturer's
limited
warranty.
Application
Guidelines/Water
Supply
Parameters
Water Supply
City or Well
Water Pressure
30 - 120 psi (207 - 827 kPa)
Water Temperature
33 ° - 100°F (0.6 ° - 37.8°C)
Service
Flow Rate
0.85 gpm
(3.2 Lpm) @ 60 psi
*Class II particle size: 1 um to <5 um
**Test requirement