26W TRIPLE TUBE LAMP, LUMEN RATING = 1710 LMS, ELECTRONIC BALLAST, CL FINISH TRIM
CANDLEPOWER SUMMARY
150
181
60˚
300
363
450
544
1
725
600
30˚
SC = 1.3
CERTIFIED TEST REPORT NO. 3067FR
COMPUTED BY LSI PROGRAM
**TEST-LITE**
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2010 Philips Group • D1110
ZONAL LUMEN SUMMARY
Zone
Lumens
Angle
0˚ CP
0
481
0-10
143.32
5
496
10-20
224.93
10
507
20-30
243.22
15
500
30-40
196.58
20
512
40-50
25
492
50-60
30
449
60-70
35
392
70-80
40
324
80-90
45
258
90-100
50
178
100-110
55
56
110-120
60
4
120-130
65
1
130-140
70
1
140-150
75
0
150-160
80
0
160-170
85
170-180
0
90
0
Architectural Decorative
ZONAL LUMENS AND PERCENTAGES
Zone
Lumens
%Lamp
%Fixt
47.69
0-30
415.94
24.3
45.2
0-40
659.16
38.5
71.7
0-60
918.96
53.7
99.9
0-90
919.93
53.8
100
90-120
0
0
0
63.22
90-130
0
0
0
.97
90-150
0
0
0
0
90-180
0
0
0
0
0-180
919.93
53.8
100
0
** Efficiency = 53.8% **
0
0
0
0
0
0
0
0
Job Information
4AWA
Pendalux ADA Wall Cirrus
COEFFICIENTS OF UTILIZATION
Ceiling
80%
70%
50%
Wall
70
50
30
10
50
10
50
10
RCR
Zonal Cavity Method - Effective Floor Reflectance = 20%
0
64
64
64
64
63 63
60 60
1
60
59
57
59
58 55
55 53
2
57
54
51
49
53 48
51
47 49 46
3
53
49
46
43
48 43
47
42
4
49
45
38
44
38 43
37
42
5
46
41
37
34
40 34
39 34
6
43
37
33
31
37
31
36 30
7
40
34 30
28
34 28 33 27
8
38
32
28
25
31
25 31
25
36
36
29
26
23
29 23
28 23
10
33
27
24
21
27
21 27
21
Determined In Accordance With Current IES Published Procedures
Luminaire Input Watts = 27.0
Type:
30%
50
10
0
57 57
54
53 52
49
44
45 41
40
37 36
41
38 33
32
35 30
29
33 27
26
30 25
24
28 23
22
26
21
20

Advertisement