Summary of Contents for Sierra Monitor Corporation ISE30 Series

  • Page 1: Technical Specification

    No.:PS##-OMF0010-C Technical Specification Digital Pressure Switch ISE30-# Series ZSE30-# Series...
  • Page 2: Table Of Contents

    Contents Safety ………………………………………………………P2 Model Indication Method ………………………………………………………P7 Specification ………………………………………………………P8 Full View with Dimensions ………………………………………………………P9 Names and Functions of Individual Parts ………………………………………………………P12 Installation ………………………………………………………P13 Examples of Internal Circuit and Wiring ………………………………………………………P15 Setting ………………………………………………………P17 Pressure Setting ………………………………………………………P19 Other Functions ………………………………………………………P21 Attached Table ………………………………………………………P22 PS##-OMF0010-C...
  • Page 3: Safety

    Safety The Digital Pressure Switch and this technical specification essential information for the protection of users and others from possible injury and damage to property and to ensure correct handling. Please check that you fully understand the definition of the following messages (signs) before going on to read the text, and always follow the instructions.
  • Page 4 Operator ♦This technical specification has been written for those who have knowledge of machinery and apparatus that use pneumatic equipment and have full knowledge of assembly, operation and maintenance of such equipment. ♦Please read this technical specification carefully and understand it before assembling, operating or providing maintenance to the pressure switch.
  • Page 5 NOTE Follow the instruction given below when designing, selection and handling your pressure switch. ♦The instructions on design and selection. Installation, wiring, environment of use, adjustment, operation and maintenance described below must also be followed. ♦Product specifications •This product designed only for the measurement of pressurized air (including vacuums). The pressurized air must contain no chemicals, synthetic oil with organic solvent, salts nor corrosive gas.
  • Page 6 •Blow off all the dust inside the pipes before piping the pressure switch. Otherwise it can cause damage or malfunction. •Clean the inside of the pipe of dust or tape sealant when screwing pipes or joints. When using tape sealant, leave a couple of screw threads unwrapped with tape sealant. Otherwise it can cause damage or malfunction.
  • Page 7 •Do not use a pressure switch nearby a place where electric surges are generated. Internal circuit elements of the pressure switch can deteriorate or break when equipment generating a large surge (electromagnetic lifter, high frequency induction furnace, motor, etc.) is located near the pressure switch.
  • Page 8: Model Indication Method

    Model Indication Method Model Indication Method For positive pressure : I S E 3 0 − − − For vacuum and low pressure : Z S E 3 0 − − − Pipe Specification R1/8 (M5 internal thread) NPT1/8(M5 internal thread) One-touch fitting φ4, φ5/32inch straight type One-touch fitting φ6 straight type One-touch fitting φ1/4 inch straight type...
  • Page 9: Specification

    Specification ZSE30 ISE30 Rated Pressure Range -100 to 100 kPa 0 to 1 MPa Set Pressure Range -101 to 101 kPa -0.1 to 1 MPa Withstand Pressure 500 kPa 1.5 MPa 0.2 kPa 0.001 MPa Setting and Display Resolution Fluids Air, inert gases and incombustible gases 12 to 24V DC, ±10%,ripple (p-p) 10% or less(Protected against inverse connection) Power Supply Voltage...
  • Page 10: Full View With Dimensions

    Full View with Dimensions Full View with Dimensions Dimensions of Main Unit PS##-OMF0010-B...
  • Page 11 Bracket supplied Panel Mount Type With Front face protective -10- PS##-OMF0010-C...
  • Page 12 Panel Cut Dimensioms -11- PS##-OMF0010-C...
  • Page 13: Names And Functions Of Individual Parts

    Names and Function of Individual Parts Operation Indicator Lamp : Displays switch operation condition. (Green LCD) LCD Display : Displays the current status of pressure, setting mode, selected indication unit and error code. Four display modes can be selected: display always in red or green only, or changing from green to red linked to output.
  • Page 14: Installation

    Installation Install using the special bracket (Article No.ZS-27-B) or the panel mount adapter (Article No.ZS-27-C) available as options. Caution : Tighten the pipe port at a clamping torque of 7 to 9N⋅m. Fasten the bracket mounting screws at a clamping torque of 0.5 to 0.7N⋅m. Mounting by Bracket Mount the bracket on the main unit using the two mounting screws M3 ×...
  • Page 15 Notice when removing the switch Digital pressure switch with adapter for panel mounting can be removed from facility by making hook of the switch wide as following. Pressure switch and Panel mount adapter may be damaged it you picked up the hook. Piping connections •Cut the tube perpendicularly.
  • Page 16: Examples Of Internal Circuit And Wiring

    Example of Internal Circuit and Wiring Output Specification When the Lead wire with connector provided by SMC CORPORATION is used, the colors of wire (Brown, Black, Blue) will apply as shown on circuit diagram. -15- PS##-OMF0010-C...
  • Page 17 Connector Connector Connecting/Disconnecting •When connecting the connector, insert it straight onto the pin holding the lever and connector body between fingers and lock the connector by pushing the lever claw into the square groove in the housing. •When disconnecting the connector, push down the lever by thumb to disengage the lever claw from the square groove.
  • Page 18: Setting

    Setting Setting Setting Procedures Measurement Mode Initialize Press the button continuously for more than two seconds. The display shown at the right will pop up to allow setting of a display color. In the case that the unit specification of model indication is M, the SL units will be fixed.
  • Page 19 4. Response Time Setting A response time for switch output can be set as user desires. Setting of a response time prevents chattering output. The response time currently set will be displayed. Select a desired response time by pressing button. (2.5ms) (20ms) (160ms)
  • Page 20: Pressure Setting

    Pressure Setting If set to Manual Setting Press the button in the Measurement mode to display set values. “P_1” or “n_1” and the current set value will flicker alternately. Press the button to display the next set value. Press the button to enter into the Value Change mode.
  • Page 21 If set to Auto Preset Mode Press the button during the Measurement mode to ready Auto Press mode and “AP1”will be displayed. Setting pressure in this condition will ready the equipment. Press the buttons simultaneously while “AP1” is displayed to return to the measurement mode.
  • Page 22: Other Functions

    Other Function Peak And Bottom Hold Display Function Maximum and minimum values are always detected and updated during measurement. Displayed values can be held. In peak hold, press the button for longer than one second to make flicker and to hold the maximum pressure value. To reset holding, press the button again for more than one second.
  • Page 23: Attached Table

    Attached Table 1. Display color Setting of figure (Display of segment in left end) Display Display Meaning character Display Display character When turning it on, it red displays it. When turning it on, it green displays it. Green 2.Output mode Setting of figure Display Display...
  • Page 24 5.Manual set Display Display Meaning character Manual set Hysteresis mode (Display when operation mode is set) Window comparator mode (Display when operation mode is set) Hysteresis mode and Window comparator mode (When P_1 of the setting of pressure is set, it displays it.) Window comparator mode (When P_2 of the setting of pressure is set, it displays it.)