Gas-fired, direct vent hot water boiler

Advertisement

Gas-Fired, Direct Vent
Hot Water Boiler
DIMENSIONS ( in inches )
Air inlet collar located on center rear of CWD193 through CWD245
*

CWD SERIES SPECIFICATIONS

D.O.E
AGA
NO. OF
HEATING
INPUT
Model
SECS.
CAPACITY
BTU/HR
BTU/HR
CWD060
3
60,000
51,000
CWD083
4
82,500
71,000
CWD110
5
110,000
94,000
CWD138
6
137,500
118,000
CWD165
7
165,000
142,000
CWD193
8
192,500
165,000
CWD220
9
220,000
189,000
CWD245
10
245,000
211,000

LOCATING THE BOILER

• Clearances: Sides 1", front 3", rear 1", top 12"
• 6" clearance to air inlet collar when combustion air is supplied from indoors
• Boiler may be installed directly on a non-carpeted combustible floor
• Relief valve may not be moved from factory location
Important: This boiler requires a special venting system.
Read instructions carefully before installing.
Heat Exchanger constructed and tested in accordance
with ASME Section IV standard.
AVAILABLE FROM:
CROWN Co-axial Horizontal Vent Terminal
IBR NET
COLLAR
WATER
DIAMETER
WIDTH
RATING
A
AFUE
INLET
EXHAUST
BTU/HR.
(inches)
(inches)
(inches)
(%)
44,000
4"
3"
16-1/8
85.1
62,000
4"
3"
19-3/4
85.1
82,000
4"
3"
23-3/8
85.2
103,000
4"
3"
27
85.2
123,000
4"
3" or 4"
30-5/8
85.2
143,000
4"
3" or 4"
34-1/8
85.2
164,000
4"
3" or 4"
32-3/4
85.2
183,000
4"
3" or 4"
41-3/8
85.3
1. Altitudes above 2,000 ft.–ratings should be reduced at a rate of 4%
for each 1,000 ft. above sea level (U.S.A. only), in Canada, boilers are
certified for altitudes up to 2,000 feet only.
2. Please specify fuel (natural gas or LPG).
3. Specifications and dimensions are subject to change without notice.
Since 1949, homeowners have depended on us
for quality, value and service
3633 I Street, P. O. Box 14818
Philadelphia, PA 19134
Phone: (215) 535-8900 Fax: (215) 535-9736
Visit us on the web: www.crownboiler.com
SHIPPING
WEIGHT
280
315
350
385
420
475
525
580
CWD-11/05-(20M)
PN980528R1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CWD060 and is the answer not in the manual?

Questions and answers

Summary of Contents for Crown Boiler CWD060

  • Page 1 Gas-Fired, Direct Vent Hot Water Boiler DIMENSIONS ( in inches ) CROWN Co-axial Horizontal Vent Terminal Air inlet collar located on center rear of CWD193 through CWD245 CWD SERIES SPECIFICATIONS D.O.E IBR NET COLLAR NO. OF HEATING WATER DIAMETER WIDTH SHIPPING INPUT Model...
  • Page 2 The power of the Cabo 2 and the efficiency of Cabo 2 and Mega-Stor… the Mega-Stor indirect water heater made for each other ...ideal for today’s Together, they assure you’ll have all the domestic hot water you need, heated with more energy than is ever homeowner who available with direct fired water heaters.

This manual is also suitable for:

Cwd083Cwd110Cwd138Cwd165Cwd193Cwd220 ... Show all

Table of Contents