CompuSTARPro CM4000 Installation Manual

Alarm/starter control module

Advertisement

Quick Links

V.37 Firmware or Greater
This manual is for authorized CompuStar Pro dealers. Please thoroughly review this manual before beginning installation. If
you have any questions please contact your distributor or tech support 888-820-3690. (8:00 am to 5:00 pm Pacific Coast Time)
This is a simplified manual. The Master Installation Manual is available on www.compustar.com.
Green/White Loop
Cut=Auto Trans. Uncut=Manual
Trans.
( + )
( - )
Door Trigger
Polarity
Default
( + )
( - )
Key
Sense/Glow
Plug Polarity
Default
( + ) Parking
Trunk
Behavior of
Lights
Release
CN1, Pin 2
Default
4 ( - )
3 ( + )
CN12
RS232
2 Data
1 Data
2 Black
CN11
Thermistor
1 Black / White
1st Stage
4 Grey / White
( + )
3 Red
CN10
Optional
2nd Stage
2 Black / White
Sensor Input
( - ) GWA
1 Black
( - ) Switch
3 Gray
CN9
Plug In
( + ) Led
2 Gray
LED/Valet
( - ) Led
1 Gray / Black
Switch
IMPORTANT: All CM4000 Control Modules need firmware updates to be 2 Way Datalink compatible. Check CompuStar.com for the latest firmware updates.
CM4000 Alarm/Starter Control Module Installation Manual
1 Red
3 Red / White
CN1
5 Violet
7 Green and
Red
CN2
1 Green /
White
3 Red / Black
5 Green
7 White /
Black
CN3
9 Black
11 Orange
13 Orange /
White
15 White
17 Violet
CN4
Jumpers
CN5
LED
CN6
Shock
Sensor
CN7
RPS Sensor
CN8
Antenna
2 Green /
1: ( + ) 12v Constant
White
3: ( + ) 12v Constant and Red/White prewired to
4 White
nd
2
Relay
5: ( - ) When Armed prewired to Starter Kill
6 Yellow
Relay
7: ( + ) Ignition and Red prewired to Starter Kill
8 Black
Relay
1 Red
1: ( + ) 12v Back Up Battery
2 Black
2: ( - ) Ground Back Up Battery
2 Lt Blue
1: ( - ) Parking Lt. Output – POC 1
4 Lt. Blue /
3: ( - ) Starter Output – POC 2
White
6 Violet /
5: ( - ) Ignition Output – POC 3
Black
8 Red / White
7: ( - ) Accessory Output – POC 4
10 Brown /
9: ( - ) Status Out (GWR) – POC 5
White
12 Pink
11: ( - ) Rearm Output – POC 6
14 Yellow /
13: ( - ) Disarm Output – POC 7
Black
16 Gray /
15: ( - ) Horn Output – POC 8
Black
18 Brown
17: ( - ) Dome Light – POC 9
None
Future use
2 Violet /
( - ) Trunk release output
White
3 Orange /
( - ) Second Unlock Output
Black
4 Blue
( - ) Unlock Output
5 Blue / Black
( - ) Lock Output
None
( + ) 12v Constant Power
Black
LED ( - )
Black / White
LED ( + )
1 Black
( - )
2 White
2nd Stage Shock
3 Red
( + )
4 Yellow
1st Stage Shock
1 Black
( - )
2 White
Knock
3 Red
( + )
4 Yellow
LED
1 Black
( - )
2 White
( + )
3 Red
TX
4 Yellow
RX
2: ( + ) Parking Light
4: ( + ) Accessory
6: ( + ) Starter prewired to Starter Kill Relay
8: ( - ) Ground
2: ( - ) E-Brake Input
4: ( + ) Brake Input
6: ( - ) Trunk Input
8: ( - / + ) Door Input
10: ( - ) Glow Input/Key Sensing
12: ( - ) Slave/Closed Loop Input
14: (AC) Tach / Alternator Input
16: ( - ) Hood Input
18: ( + ) Siren Output

Advertisement

Table of Contents
loading

Summary of Contents for CompuSTARPro CM4000

  • Page 1 ( + ) Led 2 Gray 3 Red Antenna LED/Valet ( - ) Led 1 Gray / Black 4 Yellow Switch IMPORTANT: All CM4000 Control Modules need firmware updates to be 2 Way Datalink compatible. Check CompuStar.com for the latest firmware updates.
  • Page 2 Setting Auxiliary Outputs on Connector 3 – You Must Have the OP500 Option Programmer To set auxiliary outputs on the CompuStar Pro control modules involves the new Programmable Output Connector wires (POCs). You must choose two odd pin wires on the black 18 pin connector that you are not using.
  • Page 3: Option Programming Tables

    Option Programming Tables Option Programming with Remotes and OP500, RPS Unlock and Secure Valet are programmable ONLY when system is Unlocked/Disarmed. OPTION GROUP 1 Feature Default Setting - I Optional Setting - II Optional Setting - III Optional Setting - IV Lock After Remote Start Lock After Shutdown 1-01...
  • Page 4 2-01 Tach Sensing Method – This option changes the method which is used to read tach on different vehicles. It adjusts for situations when there may be over cranking when remote starting. This option can also be adjusted based on option 2-12 – Crank Time. Please see tech update from April 2008 on www.compustar.com for more info.
  • Page 5 2-12 Crank Time – This option changes the crank time when reading tach on different vehicles. It adjusts for situations when there may be under cranking when remote starting. Please see tech update from April 2008 on www.compustar.com for more info.
  • Page 6: Quick Troubleshooting

    Option Programming Using the OP500 Option Programmer The OP500 can be used to program any available option. You must disarm the system before using. You no longer need to program the remotes before using (V.36.2 or greater). It is required to program options in Special Option Groups 1 and 2. IMPORTANT: You need to update your OP500 to read options on Version 37 or greater modules. STEP 1: Using the blue connector on the top of the OP500, connect it to the control module via the antenna wire.
  • Page 7: Relay Diagrams For Connector 1

    Relay Diagrams For Connector 1 Green/White Loop (CM4000 and CM4200DX Models) This loop wire determines the transmission setting. The default position (uncut loop) is for manual transmissions. When the loop is cut, the system will be ready for automatic transmissions. In the default (manual transmission) mode, the system must be set up in Reservation mode prior to the vehicle being able to remote start. IMPORTANT: All warranties or claims are void if a controller with a cut loop is installed on a vehicle with a manual transmission.
  • Page 8: Technical Support Contacts

    Monday - Friday 888-820-3690 (8:00 am – 5:00 pm Pacific Coast Time) Email support@compustar.com http://www.compustar.com click on “dealer support” Wire Diagrams Click on the “Installogy Access Client” link found on your desktop. If you are a qualified dealer and unable to access this site, call your sales representative or the number above.

Table of Contents