AIR LEAKS

Check the gasket on the doors to be sure of a positive air seal. Close the door on a dollar bill, then pull
the dollar bill out. If a gasket is not sealing properly, warm the gasket material with a hair drier.
Close the door and the magnetic strip should pull the gasket to the metal frame. Check that the cooling
unit is installed properly.
MODELS RM2612 & RM2812:
The refrigerator is secured in the enclosure with six screws and they must be installed in the following
order:
MODELS RM2652 & RM2852:
CONDENSATE WATER DRAIN HOSE: A 3/4"
hole must be drilled through the flooring in the
opening of the base plate on the rear of refrigera-
tor. Seal around the hose where it goes through
the hole.
The refrigerator is secured in the enclosure with
six screws. They must be installed in the follow-
ing order:
First: Two screws are installed in front
decoration strip and through the front
base.
A. The front strip is to be installed after
the refrigerator is set into the alcove.
B. Install the lower front strip by sliding it
under the bottom hinge plate as
shown.
16
First Two Screws installed on front base;
Second Two Screws installed in the top frame;
Third Two Screws installed in the rear base.