Connect only RJ-45 data connectors, network telephony
systems, or network telephones to these sockets. Either shielded
or unshielded data cables with shielded or unshielded jacks can
be connected to these data sockets.
Power Cord Set:
The power cord set must be approved for the country where it is used:
U.S.A. and
Canada
UK
Europe
Denmark
Switzerland
The cord set must be UL-approved and CSA
certified.
The minimum specifications for the flexible
cord is:
No. 18 AWG
Type SV or SJ
3-conductor
The cord set must have a rated current
capacity of at least 10A.
The attachment plug must be an
earth-grounding type with a NEMA 5-15P
(15 A, 125 V) or NEMA 6-15P (15 A, 250 V)
configuration.
The supply plug must comply with BS1363
(3-pin 13-amp) and be fitted with a 5 A fuse
which complies with BS1362.
The mains cord must be <HAR> or
<BASEC> marked and be of type
HO3VVF3G1.0(minimum).
The supply plug must comply with CEE7/7
("SCHUKO")
The mains cord must be <HAR> or
<BASEC> marked and be of type
HO3VVF3G1.0(minimum).
The supply plug must comply with Section
107-2-D1, Standard DK2-1a or DK2-5a.
The supply plug must comply with SEV/ASE
1011.