13.If the MVIP test fails, check MVIP connections and troubleshoot accordingly. If
there are any failures, note the board(s) and use the following steps to
troubleshoot the MVIP connection: (System shutdown is not necessary to MVIP
troubleshooting unless replacing a board.)
Remove the MVIP cable from all boards and check the MVIP connector on
the boards for bent or pushed down pins.
Recheck ALL MVIP configurations, including re-seating the MVIP cable
and re-checking the MVIP bus termination switches for correct
termination.
Run the MVIP test again. If the MVIP test still fails, note the failing board
and replace it. Repeat installation procedures starting from Step 1. Contact
AltiGen to RMA the defective board.
14.If the board(s) have been properly installed, the newly installed boards will
appear in the Boards View window in AltiWare Administrator.
For details on how perform functionality testing for your board(s), refer to the
System Administration manual.
Installing Channel Service Unit (CSU) to the Triton T1
or T1/E1/PRI Board
1. Connect the CSU (Adtran model T1 CSU ACE used as an example) to the T1/
PRI or T1/E1PRI board using an RJ-48C or RJ-48X cable.
2. Connect the CSU to the network termination box using an RJ-48C or RJ-48X
cable.
AltiGen T1 Socket (RJ-48)
Pin 1=Receive Ring (INPUT)
Pin 2=Receive Tip (INPUT)
Pin 4=Transmit Ring (OUTPUT)
Pin 5=Transmit Tip (OUTPUT)
Refer to your CSU manufacturer's manual for the proper pinout.