4 Absolute Ratings of Environment
Item
Storage temparature
Operating temparature
(Glass surface temperature)
Shock (non-operating)
Vibration (non-operating)
Note
(1) Temperature and relative humidity range are shown in the figure below.
90 % RH Max. (40 °C ≥ Ta)
Maximum wet-bulb temperature at 39 °C or less. (Ta > 40 °C) No condensation.
(2) 11 ms, sine wave, one time for ±X, ±Y, ±Z axis
(3) 10-300 Hz, Sweep rate 10 min, 30 min for X, Y, Z axis
(4) At vibration and shock test, the fixture which holds the module to be tested has to be hard and rigid enough so
that the module would not be twisted or bent by the fixture.
DI170S01-A01
Product No. : SA-02-015
Symbol
Min.
T
-25
STG
T
0
OPR
Snop
-
Vnop
-
Rev 1
May 23, 2005
User Manual
DI170S01-A01
Max.
Unit
Note
°C
60
°C
50
50
G
(2), (4)
1.5
G
(3), (4)
(1)
(1)
Page 4 of 16