3.2.4 3.2.4 Jumper Setting Description
Table 3.3: Jumper Setting Description
Jumper
Description
Input mode set-
JP1
ting for analog
input ch0
Input mode set-
JP2
ting for analog
input ch4
Input mode set-
JP3
ting for analog
input ch1
Input mode set-
JP4
ting for analog
input ch5
Input mode set-
JP5
ting for analog
input ch2
JP1~JP8: Input Mode Setting for Analog Input Channels
The analog input mode of every AI channel on USB-4718 can be set by
JP1~JP8 separately to measure the voltage sources or the current sources.
Inappropriate setting of the jumpers can cause unpredictable errors or
malfunction of USB-4718.
Jumper
Setting
Description
Jumper
JP6
JP7
JP8
JP13
Set the channel to voltage
input mode (Default setting)
27
Description
Input mode setting for analog
input ch6
Input mode setting for analog
input ch3
Input mode setting for analog
input ch7
Watchdog timer setting
Set the channel to
current input mode