Cuff for digital blood pressure monitors (32 pages)
Summary of Contents for Life Sourse UA-787
Page 1
UICK ESPONSE Blood Pressure Monitor Trilingual Instruction Guide – MODEL UA-787 E n g l i s h • F r a n ç a i s • E s p a ñ o l...
Page 2
THIS MONITOR IS CLINICALLY VALIDATED This LifeSource blood pressure monitor has undergone and passed a Clinical ® Validation study to determine the performance and accuracy. This monitor is clinically validated according to the British Hypertension Society (BHS) stan- dard. The BHS is the most prestigious international blood pressure organiza- tion.
IMPORTANT INFORMATION Please read this important information before using your monitor. Please remember that only a medical practitioner is qualified to inter- pret your blood pressure measurements. Use of this device should not replace regular medical examinations. Have your physician review your procedure for using this device. He or she will want to verify blood pressure measurements before pre- scribing or adjusting medications.
Page 4
Fast. Easy. Accurate. Congratulations on purchasing a state-of-the-art LifeSource ® blood pressure monitor—one of the most technologically advanced monitors available today. Designed for ease of use and accuracy, this monitor will facilitate your daily blood pressure regimen. Physicians agree that daily self-monitoring of blood pressure is an important step individuals can take to maintain car diovas- cular health and prevent the serious consequences associated with undetected and untreated hypertension.
WHAT DISPLAY SYMBOLS MEAN Display Condition/Cause Recommended Symbol Action The symbol shown while meas- Measurement is in progress, urement is in progress. It blinks remain as still as possible. while detecting the pulse. An irregular heartbeat or body Take measurement again and movement may have occurred.
MONITOR COMPONENTS SYSTOLIC PRESSURE DIASTOLIC PRESSURE MEMORY BUTTON CUFF INFLATION METER AC ADAPTER PRESSURE RATING JACK INDICATOR PULSE RATE START BUTTON CLOCK BUTTON EASY-FIT™ CUFF AIR CONNECTOR PLUG AIR HOSE BATTERY COVER AIR SOCKET BATTERY COMPARTMENT In Canada - Auto Control Medical (Toll-Free): 1-800-461-0991...
HOW UA-787 WORKS LifeSource blood pressure monitors are easy to use, accurate and digitally ® display full measurement readouts. Our technology is based on the “oscillo- metric method” – a noninvasive blood pressure determination. The term “oscillation” refers to any measure of vibrations caused by the arterial pulse. Our monitor examines the pulsatile pressure generated by the arterial wall as it expands and contracts against the cuff with each heartbeat.
SELECTING THE CORRECT CUFF SIZE Using the correct cuff size is important for an accurate reading. A cuff that is too large will produce a reading that is lower than the correct blood pressure; a cuff that is too small will produce a reading that is higher than the correct blood pressure.
TAKING YOUR BLOOD PRESSURE Adjusting the Built-in Clock The UA-787 Quick Response monitor has a built-in clock that gives you the time and date and can tell you when a blood pressure reading stored in mem- ory was taken. We recommend that you adjust the clock prior to use. To adjust the clock, follow these simple steps: Press and hold the clock button until the digits start blinking.
Page 11
TAKING YOUR BLOOD PRESSURE Setting the Alarm The UA-787 Quick Response monitor allows you to set up to three alarms per day to notify you when to take your blood pressure. To set the alarm(s): Press and hold the clock button until the digits start blinking.
Page 12
TAKING YOUR BLOOD PRESSURE Tips for Blood Pressure Monitoring: Relax for several minutes before measurement. Do not smoke or ingest caffeine at least 30 minutes prior to measure- ment. Remove constricting clothing and place cuff on bare arm. Unless your physician recommends otherwise, use left arm to measure pressure.
Page 13
TAKING YOUR BLOOD PRESSURE Press the START button. Your average blood pressure reading will appear with the number of measurements stored in memory (i.e. A25 = total of 25 measurements stored in memory). As the cuff pressurizes, measure- ment will begin and the Cuff Inflation Meter will show on the display screen.
Page 14
TAKING YOUR BLOOD PRESSURE Measurement with the desired systolic pressure: If your systolic pressure is expected to exceed 230 mmHg follow these steps: Place the cuff on the left arm, unless your physician tells you otherwise. Press and hold the START button until a number 30 to 40 mmHg higher than your expected systolic pressure appears.
WHAT IS AN IRREGULAR HEARTBEAT The UA-787 Blood Pressure Monitor provides a blood pressure and pulse rate measurement even when an irregular heartbeat occurs. The Irregular Heartbeat symbol will appear in the display window in the event an Irregular Heartbeat has occured during measurement. An irregular heartbeat is defined as a heartbeat that varies by 25% from the average of all heartbeat intervals during the blood pressure measurement.
ABOUT AVERAGE READING The UA-787 provides an average blood pressure reading based on the total measurements stored in memory. When taking a measurement, the average blood pressure reading will appear and the number of measurements stored in memory will flash several times before the cuff begins to inflate.
ABOUT MEMORY This monitor automatically stores up to sixty (280) blood pressure and pulse measurements in memory. Measurements stored in memory are assigned an index number in the order of the newest to the oldest. To retrieve readings, follow these simple steps: When the display screen is showing only the time, press and quickly release the Memory ("M") button.
USING THE MONITOR WITH AC ADAPTER The UA-787 has an AC adapter jack to allow you to supply power from an outlet in your home. We recommend you use only the LifeSource AC adapter to avoid potential damage to the monitor. Connecting the AC adapter to the monitor: Gently insert the AC adapter plug into a 120V AC outlet.
ABOUT BLOOD PRESSURE What Is Blood Pressure? Blood pressure is the force exerted by blood against the walls of the arteries. Systolic pressure occurs when the heart contracts; diastolic pressure occurs when the heart expands. Blood pressure is measured in millimeters of mercury (mmHg).
ABOUT BLOOD PRESSURE Assessing High Blood Pressure for Adults The following standards for assessing high blood pressure (without regard to age or gender) have been established as a guideline. Please note that other risk factors (e.g. diabetes, obesity, smoking, etc.) need to be taken into con- sideration and may affect these figures.
ABOUT BLOOD PRESSURE What Is Hypertension? Hypertension (high blood pressure) is the diagnosis given when readings consistently rise above normal. It is well known that hypertension can lead to stroke, heart attack or other illness if left untreated. Referred to as a “silent killer”...
Page 22
ABOUT BLOOD PRESSURE Answers to Why Your Readings Are Different Between Home and at the Doctor’s Office Why are my readings different between home and at a doctor’s office? Your blood pressure readings taken in a doctor’ s office or hospital setting may be elevated as a result of apprehension and anxiety.
Page 23
ABOUT BLOOD PRESSURE Establishing Baseline Measurements The most important method to get an accurate blood pressure measurement is consistency. To get the most benefit out of your monitor, it is important to establish a “baseline measurement.” This helps build a foundation of meas- urements that you can use to compare against future readings.
TROUBLESHOOTING Problem Probable cause Corrective action Nothing appears in Batteries are drained. Replace all batteries with new the display, after I ones. Alkaline batteries press the START recommended. button. Battery terminals are not in Reinstall the batteries with the correct position. negative and positive termi- nals matching those indicated in the battery compartment.
CONTACT INFORMATION Our products are designed and manufactured using the latest scientific and technological methods, and offer accurate, easy to use, home monitoring and treatment options. Our full product line includes: Digital Blood Pressure Monitors Manual Blood Pressure Kits Blood Pressure Cuffs Stethoscopes Personal Health Scales Pedometers...
Page 27
IMPORTANT! If You Need Assistance with the Set-Up or Operation We Can Help! Please call us FIRST before contacting your retailer at LifeSource Health Line 1-888-726-9966 - Toll Free Auto Control Medical 1-800-461-0991 - In Canada A specially trained representative will assist you.
Need help?
Do you have a question about the UA-787 and is the answer not in the manual?
Questions and answers
How do I erase all readings?