Technical Support - Maretron SSC200 User Manual

Solid state rate/gyro compass
Table of Contents

Advertisement

Electrical
Parameter
Operating Voltage
Power Consumption
Load Equivalence Number (LEN)
Reverse Battery Protection
Load Dump Protection
Mechanical
Parameter
Size
Weight
Mounting
Environmental
Parameter
IEC 60954 Classification
Degree of Protection
Operating Temperature
Storage Temperature
Relative Humidity
Vibration
Rain and Spray
Solar Radiation
Corrosion (Salt Mist)
Electromagnet Emission
Electromagnetic Immunity
Safety Precautions

9 Technical Support

If you require technical support for Maretron products, you can reach us in one of the following
ways:
Revision 1.8
9 to 16 Volts
4.46" x 3.23" x 2.14"
Deck or Bulkhead
2-13.2Hz @ ±1mm, 13.2-100Hz @ 7m/s2 per IEC 60945-8.7
12.5mm Nozzle @ 100liters/min from 3m for 30min per IEC 60945-8.8
Ultraviolet B, A, Visible, and Infrared per IEC 60945-8.10
4 times 7days @ 40°C, 95%RH after 2 hour Salt Spray Per IEC 60945-8.12
Conducted and Radiated Emission per IEC 60945-9
Conducted, Radiated, Supply, and ESD per IEC 60945-10
Dangerous Voltage, Electromagnetic Radio Frequency per IEC 60945-12
Telephone:
Fax:
E-mail:
World Wide Web:
Mail:
Value
DC Voltage
<150mA
Average Current Drain
3
NMEA 2000
Yes
Indefinetely
Yes
Energy Rated per SAE J1113
Value
Including Mounting Flanges
7 oz.
Value
Exposed
IP67
-25°C to 55°C
-40°C to 70°C
93%RH @40° per IEC60945-8.2
1-866-550-9100
1-602-861-1777
support@maretron.com
http://www.maretron.com
Maretron, LLC
Attn: Technical Support
rd
9034 N. 23
Ave Suite 13
Phoenix, AZ 85021 USA
Comment
®
Spec. (1LEN = 50 mA)
Comment
Page 19
® ®