Download Print this page

Panasonic TH-47LFT30W Brochure page 2

47-inch class outdoor lcd display
Hide thumbs Also See for TH-47LFT30W:

Advertisement

High Visibility Even in Bright Places
Usable Even Under Direct Sunlight
A trans-reflective LCD panel is used to produce
bright, clear images, and a backlight combines
with direct external lighting to enhance visibility. A
forced-air cooling system using outside air allows
the panel to withstand internal temperature rises
caused by sunlight, to extend the ambient
operating temperature range (the operating
temperature limit when the panel is mounted
facing direct sunlight*). Power consumption is
lower than panels that increase brightness by
simply raising the intensity of the backlight, which
also suppresses the internal temperature rise.
*When the panel is mounted facing direct sunlight, the operating temperature
must be under 104 °F (40 °C) instead of 113 °F (45 °C).
Touch Panel Enables a Wide Range of Information Services
Easy-to-construct interactive signage
The TH-47LFT30W is standard-equipped with a touch
panel that expands its applications in a variety of new
ways, including use in interactive signage systems.
Electrostatic
The electrostatic capacitive touch panel
capacitive
achieves a well balanced performance for
touch panel
touch panel lifetime, response, and
resolution. It also provides stable operation
under direct sunlight.
Specifications
1
IP Rating*
DISPLAY PANEL
Screen Size (Diagonal)
Aspect Ratio
Effective Display Area (W x H)
Number of Pixels (H x V)
Brightness (in dark room)
Brightness (in daylight*
Contrast Ratio
Response Time
Viewing Angle (Horizontal/Vertical)
Orientation
Touch Screen Panel
CONNECTION
HDMI IN
TERMINAL
DVI-D IN
PC IN
AUDIO IN (for DVI-D/PC)
CONTROL TERMINAL
Serial
ELECTRICAL
Power Requirements
Power Consumption
On Mode Average Power Consumption*
Power Off Condition
Stand-by Condition
AUDIO
Speaker Out
MECHANICAL
Dimensions (W x H x D)
Weight
Cabinet Material/Color
Mounting Method
ENVIRONMENTAL
Operating Environment
*1: IP=Ingress Protection *2: Measured under ambient lighting of approximately 80,000lx. *3: Based on IEC62087 Ed.2 measurement method.
*4: When the panel is mounted facing direct sunlight, the operating temperature must be under 104 °F (40 °C) instead of 113 °F (45 °C).
Trans-reflective
LCD
Indirect Light
Light Aided by
Indirect Light
Light from
Backlight
Visibility is excellent even under direct sunlight.
y is excellent even under
TH-47LFT30W
Corresponding to IP53
46.9-inch (1,192 mm)
40.9" x 23.0" (1,039 x 584 mm)
1,920 x 1,080 pixels
1,000 cd/m
2
)
1,500 cd/m
9 ms (G to G)
178° / 178°
Landscape / Portrait
Capacitance Type Touch Panel
HDMI TYPE A Connector x 2 (Deep Color Compatible)
DVI-D 24 pin (HDCP Compatible) x 1
MINI D-SUB 15 pin x1 Plug & Play (VESA DDC 2B)
M3 Jack x 1
D-SUB 9 pin x 1 (EXTERNAL CONTROL TERMINAL),
RS-232C Compatible
110-127 V AC, 50 Hz / 60 Hz
3
Save ON 0.1 W, Save OFF 0.2 W
8 Ω, 10 W [5 W + 5 W] (10 % THD)
45.3" x 27.4"x 10.7" (1,149 x 694 x 271 mm)
Approx. 136.7 lbs, (62 Kg)
Aluminum / Silver
VESA 15.8" x 15.8" (400 x 400 mm)
Temperature: 32 °F to 113 °F (0 °C to 45 °C*
Temperature (Winter Mode): -4 °F to 113 °F (-20 °C to 45 °C*
Humidity: 20 % to 90 %
Film to Prevent
Scattered Reflections
Liquid Crystal Panel
Trans-reflective Film
Backlight passes through,
and external light is
reflected.
Backlight
16:9
"Degree of protection IP53" holds considerable
2
(Typ)
dust proofing. It can be installed in dusty
2
(Max)
environments.
1,000 : 1
310 W
250 W
0.1 W
4
)
4
)
Forced
Outside air is pulled into the cabinet to
Air Cooling
create an airflow between the front
System
glass and the LCD panel, to suppress
internal temperature rises.
internal temperature rises.
Air flow
Temperature rises inside the liquid crystal are
mperature rises inside the liquid crystal ar
suppressed to prevent blackouts.
Dustproof and Water Resistant for
Outdoor Installation
The dustproof and water resistant
equivalent to IP53
This denotes the degree of dust-proofing and
What is
water resistance. IP is an abbreviation of the
IP?
international standard Ingress Protection
IP- 5 3
Dust Proofing
Water Resistance
Level of protection from
Level of water resistance
dust particles
Level
Degree of Protection
Level
Degree of Protection
Protection from 4
Protection from
5
3
micron dust particles
a water spray
Simulated pictures on screen.
Design and specifications are subject to change without notice.
heat
heat
heat
As of August 29, 2011.
(For Americas)
CR11LFT30_U03

Advertisement