  • Page 37: Installation Instructions

    Dual Fuel Cooker G.C. Number: L.P.GAS WHITE INSTALLATION INSTRUCTIONS THIS APPLIANCE IS ONLY AVAILABLE FOR USE WITH L.P.GAS. CHECK THAT THIS MODEL IS SUITABLE FOR THE TYPE OF SUPPLY AVAILABLE. IN THE INTEREST OF SAFETY THIS APPLIANCE MUST BE INSTALLED AND/OR SERVICED BY A COMPETENT PERSON AS STATED IN THE GAS SAFETY (INSTALLATION AND USE) REGULATIONS CURRENT EDITIONS.
  • Page 38: Technical Data

    CONTENTS Technical Data Safety Requirements Provision for Ventilation Location of Appliance Installation Testing TECHNICAL DATA DIMENSIONS Height to hotplate Space for fixing at hotplate level Space for fixing above hotplate level Minimum space above hotplate Weight of appliance Minimum distance from rear wall CONNECTIONS Electric IGNITION...
  • Page 39: Provision For Ventilation

    MAIN OVEN Heat Input GENERAL Ignition Spark Gap IMPORTANT - SAFETY REQUIREMENTS This appliance must be installed in accordance with the Gas Safety (Installation and Use) Regulations Current Editions and the I.E.E. Wiring Regulations. Detailed recommendations are contained in the following British Standard Codes of Practice - BS.6172, BS.5440: Part 2 and B.S.6891.
  • Page 40: Location Of Appliance

    LOCATION OF APPLIANCE This is a type X appliance which means it is freestanding and can be fitted with cabinets on one or both sides. This appliance must not be installed in a bed-sitting room of volume less than 20m³ or in a bathroom or shower room.
  • Page 41: Levelling The Appliance

    INSTALLATION 1. PARTS REQUIRED The loose hotplate parts are packed in the polystyrene fitment on top of the hotplate. 2. LEVELLING THE APPLIANCE If the appliance requires levelling or its height adjusting (from the hotplate to any working surface), the procedure below must be followed: Loosen the lock nuts securing the rear wheels, using a 13mm spanner.
  • Page 42: Fitting The Stability Bracket

    FITTING THE STABILITY BRACKET It is recommended that if the appliance is to be installed with a flexible supply pipe a stability bracket (SK.4729.A) is fitted and is available from your supplier (see Important Safety Requirements, Page 3). These instructions should be read in conjunction with the leaflet packed with the stability bracket. Place the appliance in its intended position and level appliance.
  • Page 43: Connecting To Gas

    4. CONNECTING TO GAS This appliance is designed to be installed with an appliance flexible connection only. (The flexible supply pipe must be suitable for use at 70° above ambient). Supply piping should not be less that R³/ is made to the Rc ½ (½" B.S.P.) female threaded entry pipe located just below the hotplate level on the rear left hand side of the appliance.
  • Page 44: Pressure Testing

    If the wiring is extended or a completely new cable fitted a 3-pin 13 amp plug should be fitted. (See Fig.4a). Connect the wires as follows: BROWN to the Live Terminal. BLUE to the Neutral Terminal. GREEN and YELLOW to the Earth Terminal. As the colours of the wires in the mains lead which you fit may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows:...
  • Page 45: Checking The Main Oven

    10. CHECKING THE MAIN OVEN CONTROLS TO SET THE TIME OF DAY (see Fig.5) Turn on the electricity supply and ensure that the thermostat is in the off position. Before setting timer read important note below. Rotate the left hand clock knob to manual and back to the clock position.