SERIAL Terminals connection

The SERIAL terminal is used when the Plasma Display is controlled by a computer.
Note: To use serial control for this unit, make sure to set the "CONTROL I/F SELECT" in the "NETWORK SETUP" menu
to "RS-232C". (refer to "Operating Instructions, Network Operations")
COMPUTER
Notes:
• Use the RS-232C straight cable to connect the computer to the Plasma Display.
• The computer shown is for example purposes only.
• Additional equipment and cables shown are not supplied with this set.
The SERIAL terminal conforms to the RS-232C interface
speci¿ cation, so that the Plasma Display can be controlled
by a computer which is connected to this terminal.
The computer will require software which allows the sending
and receiving of control data which satis¿ es the conditions
given below. Use a computer application such as programming
language software. Refer to the documentation for the
computer application for details.
Communication parameters
Signal level
Synchronization method
Baud rate
Parity
Character length
Stop bit
Flow control
Basic format for control data
The transmission of control data from the computer starts with
a STX signal, followed by the command, the parameters, and
lastly an ETX signal in that order. If there are no parameters,
then the parameter signal does not need to be sent.
STX
C1 C2 C3
:
Start
3-character
(02h)
command (3 bytes)
Notes:
• If multiple commands are transmitted, be sure to wait for
the response for the ¿ rst command to come from this unit
before sending the next command.
• If an incorrect command is sent by mistake, this unit will
send an "ER401" command back to the computer.
• S1A and S1B of Command IMS are available only when a
dual input terminal board is attached.
• Consult an Authorized Service Center for detail instructions
on command usage.
RS-232C Straight cable
D-sub 9p
RS-232C compliant
Asynchronous
9600 bps
None
8 bits
1 bit
-
P1 P2 P3 P4
P5
ETX
Colon
Parameter(s)
(1 - 5 bytes)
(Male)
(Female)
Signal names for D-sub 9P connector
These signal names are those of computer speci¿ cations.
Command
Command
PON
POF
AVL
AMT
IMS
End
(03h)
DAM
With the power off, this display responds to PON command only.
Connections
Pin layout for SERIAL Terminal
Pin No.
2
3
5
4
6
7
8
1
9
Parameter
None
Power ON
None
Power OFF
**
Volume 00 - 63
0
Audio MUTE OFF
1
Audio MUTE ON
None
Input select (toggle)
SL1
SLOT input (SLOT INPUT)
S1A
SLOT input (SLOT INPUT A)
S1B
SLOT input (SLOT INPUT B)
VD1
VIDEO input (VIDEO)
YP1
COMPONENT/RGB IN input
(COMPONENT)
HM1
HDMI input (HDMI)
DV1
DVI-D IN input (DVI)
PC1
PC IN input (PC)
NW1
Network input (NETWORK)
None
Screen mode select (toggle)
ZOOM
ZOOM (For Video/SD/PC signal)
FULL
FULL
JUST
JUST (For Video/SD signal)
NORM
4:3 (For Video/SD/PC signal)
SJST
JUST (For HD signal)
SNOM
4:3 (For HD signal)
SFUL
H-FILL (For HD signal)
ZOM2
ZOOM (For HD signal)
9
8
7
6
5
4
3
2
1
Details
R X D
T X D
GND
Non use
(Shorted in this set)
NC
Control details