PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS AT 37°/0°
CONTROL SETTING
Variable Speed Compressor
65°F (18°C) Ambient
Operating Time
32 to 40%
-6° to 6° F
Freezer Temperature
-21° to -14° C
33° to 46° F
Refrigerator Temperature
0.5° to 8° C
Low Side Pressure
5 to 12 psig
(cut-in)
34 to 83 kPa
Low Side Pressure
-2 to 2 psig
(cut-out)
-14 to 14 kPa
85 to 95 psig
High Side Pressure
586 to 655 kPa
Wattage
40 to 55
Amps (running)
.5 to 1.1
Base Voltage
115 vac (127 vac max)
DEFROST SPECiFiCATiONS
Thermostat
Cabinet Size
Cut-in
Cut-out
25° F
47° F
26' & 28' SD, 23' CD
(-4° C)
(8° C)
Electronic Timer - (ADC) Defrost 24 minutes every 6-96 hours of compressor run time.
CONDENSER FAN MOTOR
Watts
RPM
3.1
1100 CW
(Energy Star, some models)
Opposite Shaft
iCE MAKER SPECiFiCATiONS
Electrical
115 vac (127 vac max)
Thermostat
Opens at 48° F (9° C), Closes at 15° F (-9° C)
Heater Voltage
85 vac
iCE MAKER CONNECTOR PLUG CONNECTiONS
Wire Number
Wire Color
1
Green/Yellow
2
Yellow
3
Black
4
Light Blue
SERViCE DATA SHEET - 240389644
90°F (32°C) Ambient
FREEZER iCE MAKER - AUTOMATiC DEFROST
100%
BOTTOM FREEZER - R134a
-6° to 6° F
-21° to -14° C
33° to 46° F
iMPORTANT SAFETY NOTE
0.5° to 8° C
The information provided herein is designed to assist qualified
N/A
repair personnel only. Untrained persons should not attempt to
-2 to 2 psig
make repairs due to the possibility of electrical shock. Disconnect
-14 to 14 kPa
power cord before servicing this appliance.
120 to 135 psig
iMPORTANT
827 to 931 kPa
60 to 70
If any green grounding wires are removed during servicing, they
.7 to .9
must be returned to their original position and properly secured.
CAUTiON
Heater
Watts
Ohms
All electrical parts and wiring must be shielded from torch
flame. DO NOT allow torch to touch insulation; it will char
500
26
at 200°F and flash ignite (burn) at 500°F. Excessive heat
will distort the plastic liner.
Amps
NOTE
0.03 Running
This product comes equipped with an Adaptive Defrost Control
(ADC). To activate manual defrost, simultaneously press and
hold the Fresh Food up (+) and Fresh Food down (-) keys for 5
seconds. A "d" in the freezer temperature window and "F" in the
refrigerator temperature window will display when the heater is
activated. To deactivate manual defrost, simultaneously press and
hold the Fresh Food up (+) and Fresh Food down (-) keys for 5
Connects to:
seconds. A "d" and "F" will be displayed until the defrost cycle is
Ground
complete.
Water Valve
Line
iMPORTANT
Neutral
PLEASE RETURN THiS SHEET TO iT'S ORiGiNAL
LOCATiON
iCE MAKER iNFORMATiON
Test Cycling
Remove cover by inserting screwdriver in notch at bottom and
prying cover from housing. Use screwdriver to rotate motor gear
counterclockwise until holding switch circuit is completed. All
components of ice maker should function to complete the cycle.
Water Fill
Water Fill Volume
Adjustment
The water fill adjustment
Motor
Gear
screw will change the fill
time. One full turn is equal
to 20cc (.68 oz.). The
correct fill is 102 to 130cc
(3.4 to 4.3 oz.). When a
water valve is replaced,
Mounting
Plate
the fill volume must be
Screw
checked.
LINE
POWER
ICE MAKER
BRN
BLK
P-3
THERMAL
CUT-OUT
MOTOR
HOLD
SWITCH
NO
RED
THERMOSTAT
NC
C
BLK
MOLD HEATER
165 WATTS
GRN / YEL
P-1
C
WATER FILL
MOLD
MOUNTING
SWITCH
PLATE
ICE MAKER
Mounting
Plate
Screws
Timing
Gear
NEUTRAL
RED
YEL
P-4
NO
BLU
NC
C
SHUT-OFF
NO
SWITCH
NC
LT. BLU
P-2

Advertisement

loading

Summary of Contents for Frigidaire FGHG2344ME

  • Page 1 PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS AT 37°/0° SERViCE DATA SHEET - 240389644 CONTROL SETTING iCE MAKER iNFORMATiON Variable Speed Compressor 65°F (18°C) Ambient 90°F (32°C) Ambient FREEZER iCE MAKER - AUTOMATiC DEFROST Test Cycling Operating Time 32 to 40% 100% BOTTOM FREEZER - R134a -6°...
  • Page 2 242107201 Wiring Diagram Frig FDBF 2500++ V4 non Dispenser Ice Maker Errors Displayed on “UI” System Error Codes Displayed on “UI” Diagnostic Mode Note: See Service Manual for complete description. ERROR Test Activate: FZ (+) and FZ (-) for 5 sec. OP or 2 Freezer Sensor OPEN Standard compressor...