Resolved Caveats-Cisco Nx-Os Release 4.1(3)N1(1) - Cisco AP775A - Nexus Converged Network Switch 5010 Release Note

Cisco nexus 5000 series release notes release 4.1(3)n1(1) (ol-16601-01 h0, july 2009)
Hide thumbs Also See for AP775A - Nexus Converged Network Switch 5010:
Table of Contents

Advertisement

S e n d d o c u m e n t a t i o n c o m m e n t s t o n x 5 0 0 0 - d o c f e e d b a c k @ c i s c o . c o m
Resolved Caveats—Cisco NX-OS Release 4.1(3)N1(1)
This section lists the resolved caveats for this release.
OL-16601-01
Workaround: Use the Ethernet SPAN destination port to SPAN Fibre Channel traffic. FCoE packet
going out of the Ethernet SPAN destination port will contain VSAN information in the Ethernet
VLAN tag.
CSCsv93278
Symptom:The logging server vrf command works only with the management vrf. There is no
functional impact if the syslog is to be sent over management vrf.
Workaround: None.
CSCsv93922
Symptom: If the modulo(%) operator is used in a Cisco Nexus 2000 Series Fabric Extender
description the show fex <fex-id> command brings up the following error message
ERROR: bad format: non escaped % not followed by 's'.
Workaround: Remove the modulo(%) operator from the Cisco Nexus 2000 Series Fabric Extender
description
CSCsv95478
Symptom:The Cisco Nexus 2000 Series Fabric Extender pinning redistribute command does not
wait for user prompt with a yes or no operation.
Workaround: None.
CSCsv15775
Symptom: When priority tagged frames are received on Cisco Nexus 2000 Series Fabric Extender
ports, they are dropped and not forward on the nativeor default VLAN of the port. The MAC
addresses are not learned.
Workaround: None.
CSCsx39376
Symptom: If user is created w/ AES privacy password and login without the privacy password, user
won't be able to delete any normal user. System will just times out
Workaround: If user is created w/ A
CSCsw39639
Symptom: When a rule that refers to a specific interface name (e.g. Ethernet 1/1) is entered in the
role definition CLI, the command could hang. Ctrl-C can be issued to get back the CLI prompt.
Workaround: Do not configure rules that refer to specific interfaces in the role definition CLI.
CSCsv13371
Symptom: Interface reset and clearing counters do not get updated.
Workaround: None
CSCsv65911
Symptom: The RMON alarm configuration is not shown when issuing show running-config. This
is only a show issue, the configuration gets saved correctly with copy running-config startup-config
and is restored correctly after a reload.
Workaround: None.
Cisco Nexus 5000 Series and Cisco Nexus 2000 Series Release Notes, Release 4.1(3)N1(1)
Caveats
17

Advertisement

Table of Contents
loading

Table of Contents