Cisco AJ732A - MDS 9134 Fabric Switch Release Note page 46

Cisco mds 9000 family release notes for cisco mds nx-os release 4.1(3a) (ol-17675-05 e0, march 2009)
Hide thumbs Also See for AJ732A - Cisco MDS 9134 Fabric Switch:
Table of Contents

Advertisement

Caveats
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c . c o m .
Table 15
DDTS Number
CSCsv40524
CSCsw48060
CSCsw78035
CSCsx39090
CSCsy52780
CSCsy35135
CSCsy37951
Resolved Caveats
Cisco MDS 9000 Family Release Notes for Cisco MDS NX-OS Release 4.1(3a)
46
Open Caveats and Resolved Caveats Reference (continued)
CSCsi72048
Symptom: FCIP links may fail on an MDS 9216i switch that has compression set to auto when the
other end of the FCIP link is terminated by an IPS-8 module. You may see the following message in
the logs:
%IPS_SB_MGR-SLOT1-3-CRYPTO_FAILURE: Heartbeat failure in encryption engine (error
0x1)
%ETHPORT-5-IF_DOWN_SOFTWARE_FAILURE: Interface GigabitEthernet1/1 is down (Port
software failure)
%PORT-5-IF_DOWN_SOFTWARE_FAILURE: %$VSAN 1%$ Interface fcip99 is down (Port software
failure)
Workaround: This issue is resolved.
CSCsk11207
Symptom: Using Fabric Manager Web Client, you download Fabric Manager Client and when
prompted to create a desktop shortcut, you select Yes. The default shortcut named "Cisco Fabric
Manager" is created on the desktop. Then, using Fabric Manager Web Client again, you download
another Fabric Manager Client from a different server (usually this will be a different version of
Fabric Manager Client). You will not be prompted to create another shortcut because a desktop
shortcut titled "Cisco Fabric Manager" already exists from the first installation.
Workaround: This issue is resolved.
CSCsq78868
Symptom: Flow statistics on a Generation 2 module may not be accurate if any of the flows that
participate in flow statistics on the module have multiple FSPF paths.
Workaround: This issue is resolved.
CSCsu31909
Symptom: A failure in the internal software on the MSM-18/4 module causes an FCIP link in the
PortChannel to drop.
Workaround: This issue is resolved.
NX-OS Software Release (Open
or Resolved)
4.1(1c)
O
O
O
O
NX-OS Software Release (Open
or Resolved)
4.1(3a)
R
R
R
R
O
O
O
OL-17675-05