NORMAL INSTALLATION STEPS
ANTI-TIP BLOCK INSTALLATION INSTRuCTIONS
To reduce the risk of tipping of the drawer, the Anti-Tip block
must be properly installed located 9-inches above the floor on
which the Warming Drawer will sit. The 6-inch Anti-Tip block
must be provided by the installer. See Figures 1, 2, and 4. The
Anti-Tip block prevents serious injury that might result from
spilled hot liquids.
If the Warming Drawer is ever moved to a different location, the
Anti-Tip block must also be moved and installed. When installed
to the wall, make sure that the screws completely penetrate the dry
wall and are secured in wood or metal so that the block is totally
stable. When fastening, be sure that the screws do not penetrate
electrical wiring or plumbing.
9" (228.6 mm)
4"
Figure 5
(101.6 mm)

groUnDing instrUctions

This appliance must be grounded. The Warming Drawer is equipped with a cord having a grounding
wire with a grounding plug. It must be plugged into a wall receptacle that is properly installed
and grounded in accordance with the National Electrical Code and local codes and ordinances.
In the event of an electrical short circuit, grounding reduces risk of electric shock by providing
an escape wire for the electric current.
– Improper use of the grounding plug can result in a risk of electric shock. Do
not use an extension cord. If the power supply cord is too short, have a qualified electrician or
serviceman install an outlet near the appliance.
DraWer installation
Carefully guide the drawer into the prepared opening. Avoid
pinching the cord between the oven and the wall.
Slide the drawer all the way until the mounting flange is flush
with the face of the cabinet.
Open the drawer. Using the 4 holes on the drawer as a template,
predrill the cabinet using a 1/16" bit. See Figure 7A.
Secure the drawer with the 4 screws supplied. See Figure 7B.
Plug the power supply cord into the electrical outlet.
electrical oUtlet
The electrical requirements are a 120 volt 60 Hz, AC only, 15
amp. or more protected electrical supply. It is recommended that
a separate circuit serving only this appliance be provided.
The drawer is equipped with a 3-prong grounding plug. It must
be plugged into a wall receptacle that is properly installed and
grounded. Should you only have a 2-prong outlet, have a qualified
electrician install a correct wall receptacle.
Note: If you have any questions about the grounding or electrical
instructions, consult a qualified electrician or service person.
10"
6" (153 mm)
5"
Anti-tip
Block
Solid
Floor
Figure 7A
Figure 8A
E3
Electrical
outlet zone
10"
1½"
Anti-tip
10"
6"
9" cutout opening
Locate outlet in available space
adjacent to the warming drawer.
10"
10"
30"
Permanent and Correct Installation
3-Prong Plug
Grounding Pin
3-Prong Receptacle
Grounded Receptacle Box
x
1½"
38"
5"
Figure 6
Parts Supplied
4 Screws
Figure 7B