Electrolux EI23CS65KS Service Data Sheet

Side by side refrigerator

Advertisement

PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS AT 0° F FREEZER & 37° F
FRESH FOOD (2500 ++ V5)
65°F (18°C) Ambient
Type A with Run/Start
Capacitor
Variable Speed
Standard
Variable Speed
Operating Time
74 to 84%
32 to 40%
100%
-2° to 2° F
0° to 4° F
-1° to 3° F
Freezer Temperature
-19° to -17° C
-18° to -16° C
-18° to -16° C
34° to 39° F
34° to 39° F
34° to 39° F
Refrigerator Temperature
1° to 4° C
1° to 4° C
1° to 4° C
5 to 12 psig
5 to 12 psig
Low Side Pressure (cut-in)
43 to 83 kPa
43 to 83 kPa
-2 to 2 psig
-2 to 2 psig
-2 to 2 psig
Low Side Pressure (cut-out)
-14 to 14 kPa
-14 to 14 kPa
-14 to 14 kPa
High Side Pressure
90 to 105 psig
90 to 115 psig
120 to 135 psig
(last 1/3 cycle)
621 to 724 kPa
621 to 793 kPa
827 to 931 kPa
Wattage (last 1/3 cycle)
50 to 60
90 to 130
60 to 70
Amps (running)
0.5 to 0.9
0.7 to 1.1
0.6 to 1.0
Base Voltage
115 vac (127 vac max)
DEFROST SPECIFICATIONS
Thermostat
Cabinet Size
Cut-in
Cut-out
Watts
23' CD, 26'
25° F (-4° C)
47° F (8° C)
Electronic Timer - (ADC) Defrost 24 minutes every 6-96 hours of compressor run time.
CONDENSER FAN MOTOR
Watts
RPM
3.1
1100 CW Opposite Shaft
90°F (32°C) Ambient
Standard
55 to 65%
-1° to 3° F
-18° to -16° C
IMPORTANT: PLEASE RETURN THIS SHEET TO ITS ORIGINAL LOCATION
34° to 39° F
1° to 4° C
Error Codes
5 to 12 psig
N/A
43 to 83 kPa
Display
-2 to 2 psig
FZ
FF
-14 to 14 kPa
--
OP-
130 to 155 psig
896 to 1069 kPa
--
OP¯
100 to 140
0.8 to 1.2
OP
--
--
SH-
Heater
--
SH¯
Ohms
450
30
SH
--
SY
CF
Amps
SY
CE
0.03 Running
SY
EF
SERVICE DATA SHEET
240389648
ICE & WATER - AUTOMATIC DEFROST
SIDE BY SIDE - R134a
Special Modes
Display
Activate/Deactivate
Interpretation
Mode
(press for up to 10 sec.
FZ
FF
simultaneously)
Open FF mid-level
Manual
d
F
FF UP and FF DOWN/
thermistor
Defrost
same to deactivate
Open FF upper-level
Display/
77
77
FZ UP and FF DOWN/
thermistor
Showroom
Power-on-Reset (POR)
Open FZ thermistor
Sabbath
Sb
Sb
FZ DOWN and FF UP/
same to deactivate
Shorted FF mid-level
Diagnostic
No FF or FZ display,
FZ UP and FZ DOWN/FF
thermistor
all UI LEDs on.
UP to deactivate
Shorted FF upper-level
Notes:
thermistor
• Always check for pin back-outs, pinched or damaged wires
before replacing components.
Shorted FZ thermistor
• Determine whether failure is caused by the component, main
control board or wiring. Contact TID before replacing main
UI to Main Control Board
control board.
communication failure;
• Refer to Service Manual for additional information.
on start up
UI Main Control Board
communication error;
after a period in operation
Evaporator fan failure
Diagnostic Mode
Activate:
Press FZ UP and FZ DOWN temperature pads for up to 10 sec. simultaneously.
Press FF UP to advance through tests.
Deactivate:
Press FF UP for up to 10 sec. Diagnostic Mode will automatically deactivate after 5 min. of
inactivity. Note: Silence alarm.
• Tests marked with "*" may not be applicable to this unit and will not be displayed in Diagnostic Mode.
• Tests displayed in diagnostic mode but not described below are for internal purposes only; advance through.
• View UI display for "on," "off," "CL," "OP," "SH," "LO," "HI" or numerical results of tests.
• Listen for operating sounds; feel for heat or air flow as appropriate to determine results of tests.
Test
To activate test:
Passing result
--
First Screen
--
All LED lights on UI illuminated
--
Second Screen
--
All segments on UI temperature displays illuminated
--
Third Screen
--
Blank UI display, no lights illuminated, no shadowing; "-" and "+"
blinking on FF display side to show location.
28
Dispenser Paddle
Press disp. paddle
"on" on UI when depressed; "off" when released
1*
Standard
Press power on-off
Compressor running when "on"; stopped when "off"
Compressor
2
Defrost Heater
Press power on-off
Defrost limit switch must be closed; verify "CL" in test 26.
Feel for heat from defrost heater when "on".
If "OP" in test 26, heater will not activate.
3
FF Light
Press power on-off
With FF door open, FF lights on when "on"; off when "off"
8
Water Valve
Press power on-off
FF door must be closed.
(Dispenser)
Be prepared to collect water at dispenser.
Water dispenses when "on"; stops when "off"
9
FZ Light
Press power on-off
With FZ door open, FZ lights on when "on", off when "off"
10
Auger Motor
Press power on-off
FF door must be closed.
Motor running when "on"; motor stopped when "off"
FF door must be closed. Do not leave solenoid in activated state.
11
Cube/Crush
Press power on-off
Solenoid
Solenoid activated when "on"; deactivated when "off"
41*
Perfect Temp Drawer
Press power on-off
PTD UI illuminated when "on", off when "off"
(PTD)
12*
VCC Condenser Fan
Press power on-off
Fan running when "on"; stopped when "off"
38*
VCC Compressor
Press power on-off
Compressor running when "on"; stopped when "off"
15
Evaporator Fan
Press power on-off
Fan running for minimum of 10 sec. when "LO" or "HI"; stopped when
"off". Feedback failure if fan starts but runs less than 10 sec. Listen for
speed change from "LO" to "HI".
22
Damper
Press power on-off
With inspection mirror, observe damper open when "OP"; closed when "CL"
23
FF Door
Open/close FF door
"CL" on UI when door closed; "OP" when open
24
FZ Door
Open/close FZ door
"CL" on UI when door closed; "OP" when open
26
Defrost Limit Switch
Activates automatically
"CL" on UI when closed; "OP" when open
36
Ice Chute Door
Depress ice chute door
"OP" on UI when manually opened; "CL" when closed. Or, using "power
or press power on-off
on-off", "OP" on UI when solenoid activated, "CL" when deactivated
29
FF Thermistor
Activates automatically
UI shows temperature sensed by FF thermistor; pass if within 10°F of
Mid-level
temperature measured with gauge at mid-level FF thermistor location.
"OP-" if open; "SH-" if short
30
FZ Thermistor
Activates automatically
UI shows temperature sensed by FZ thermistor; pass if within 10°F of temperature
measured with gage at FZ thermistor location.
"OP" if open; "SH" if short
33
Ambient Thermistor
Activates automatically
UI shows temperature sensed at main board; pass if within +20°F/-10°F
@ Main Board
of temperature measured with gauge at main board location.
"OP" if open; "SH" if short
35
FF Thermistor
Activates automatically
UI shows temperature sensed by upper level FF thermistor; pass if within
Upper-Level
10°F of temperature measured with gauge at upper-level FF thermistor
location. "OP¯" if open; "SH¯" if short
34
Ambient Thermistor
Activates automatically
UI shows temperature sensed at UI; pass if within +20°F/-10°F of tem-
@ UI
perature measured with gauge at UI location. "OP" if open; "SH" if short
0-
Firmware
Press power on-off
Displays digit sequence; record
Parameters
2-
Main Board
Press power on-off
Displays digit sequence; record
Firmware
4-
UI Firmware
Press power on-off
Displays digit sequence; record
IMPORTANT SAFETY NOTE
The information provided herein is designed to assist qualified repair personnel only. Untrained persons should not attempt to make
repairs due to the possibility of electrical shock. Disconnect power cord before servicing this appliance.
IMPORTANT
If any green grounding wires are removed during servicing, they must be returned to their original position and properly secured.
CAUTION
All electrical parts and wiring must be shielded from torch flame. DO NOT allow torch to touch insulation; it will char at
200°F and flash ignite (burn) at 500°F. Excessive heat will distort the plastic liner.