Closet installation - Dryer only
_"_
48 in. 2.
(310 cm;
24 in?*
(155 crn 2) '
(2.5 cm) (72.77 crn)(12.7 crn)
A
B
A. Side view - closet or confined area
B. Closet door with vents
E}
3"*
'--_ (7.6 crn)
*Required spacing
**For side or bottom venting, 0" (0 cm) spacing is allowed.
Recessed
or closet installation
- Dryer on pedestal
1"-_4I*-
27,, --_11_- 1,,
(2.5 cm)
1"* I I_- 28.6s"--_ls"**l
(68.6 crn)
(2.5 crn)
(2.5 cm)
(72.77 cm) (12.7 cm)
A
B
A. Recessed area
B. Side view- closet or confined area
*Required spacing
**For side or bottom venting, 0" (0 cm) spacing is allowed.
Recommended installation spacing for cabinet
installation
For cabinet installation, with a door, minimum ventilation
openings in the top of the cabinet are required.
11
1"
27"
1"
(12,7 crn) (72.77 crn) (2.5 cm) (2.5 cm)(68,6
crn)(2.5 crn)
*Required spacing
**For side or bottom venting, 0" (0 cm) spacing is allowed.
Recommended
installation spacing for recessed or
closet installation,
with stacked washer
and dryer
The dimensions
shown are for the recommended
spacing.
48 in.2 *
(310 cm 2)
2L
24 in. 2 *
(165 crn_)
*Required spacing
(12.7 cm)
2L
3"* (7.6 cm)
I,
3"* (7.6 crn)
t
72"
(182,9 crn)
_r-
1"
--_
(2.6 _rn)
*Required spacing
68.6 cm
Mobile home - additional
installation
requirements
This dryer is suitable for mobile home installations.
The installation must conform to the Manufactured
Home
Construction
and Safety Standard, Title 24 CFR, Part 3280
(formerly the Federal Standard for Mobile Home Construction
and Safety, Title 24, HUD Part 280).
Mobile home installations
require:
Metal exhaust system hardware, which is available for
purchase from your dealer.
Special provisions must be made in mobile homes to
introduce outside air into the dryer. The opening (such as a
nearby window) should be at least twice as large as the dryer
exhaust opening.