Frigidaire FAQE7072LA Datasheet page 3

Wiring diagram (all languages)
Hide thumbs Also See for FAQE7072LA:
Table of Contents

Advertisement

Available languages

Available languages

Selector
Test/Activated Component
Position
Electric
Lights / Buttons test
0
Motor Clockwise (CW)
1
Contact Sensor
2
3
Motor Clockwise (CW)
Lights / Buttons
4
test + Motor CW
5
Motor CW + Heater
1
6
Motor CW + Heater
1 + Heater 2
Motor CW + Heater
7
1 + Heater 2 +
Heater 3
8
Motor CW
Error code history display
9
Software version
10
NOTE : To clear the error code (s): Press and hold the center key under the display and "cancel" buttons
simultaneously for 3 seconds.
6. To exit Diagnostic Mode:
a) Unplug the power cord, wait 5-8 seconds, then reconnect the power cord OR
b) Turn the program knob to the Start Position (lights/Buttons Test). Press the "cancel" and center button
display simultaneously for 6 seconds.
Diagnostic Mode
Operator Check
Gas
Check Motor function. Look for Drum
rotation in clockwise direction
Check moisture reading. Place fingers
across Contact Sensor and look for digit
display to change from "1111" to "8888"
Check Motor function. Look for Drum
rotation in clockwise direction
Check all buttons and lights. Press all
Lights / Buttons
buttons and check for beep and button
test + Motor CW +
ID number in digit display. Check to see
igniter
that all Lights function
Check Motor and Heater function. Check
Motor CW +
Outlet Control Thermistor value in digit
Heater
Check Motor and Heater function.
Motor CW +
Heater
Check Motor and Heater function. Check
Motor CW +
Outlet Control Thermistor value in digit
Heater
Check last 5 error codes displayed (See
Table above for error code definitions)
display.
display.
Check for Mist
Software version
3
LCD row
LCD digits
"MOTOR CW"
"1111" if Contact Sensor
open circuit;"8888" if
"MOIST. BARS"
Contact Sensor short
circuited
"MOTOR CW"
button id number
Outlet Control Thermistor
"HEAT1 - NTC1"
value (degrees F)
Inlet Control Thermistor
"HEAT2 - NTC2"
value (degrees F)
"HEAT3 - NTC1"
Outlet Control Thermistor
value (degrees F)
"MIST VALVE"
error code
Software
Software version
version
under the