Connections for 25 Way male Connector
Max cable length is 5m using standard
alarm cable or 30m using twin twisted-pair
(use 0V in each pair)
NETWORK
A
B 0V
ACT 2000
1. Ask the network administrator to supply you with a permanent IP network address.
2. Connect a PC directly to the ACTLAN and run HyperTerminal at 9600 baud, no parity, 1 stop.
3. Power up the ACTLAN and immediately hit 3 lowercase "x" (xxx).
4. Hit the Enter key to go inte Setup Mode.
5. Select 0 and follow the prompts until you get to IP address.
6. Enter the new IP address.
7. If the ACT controllers are on a different LAN segment to the ACTWin Pro PC, then a Gateway
Address is required. Check with the network administrator for the IP address of the router.
8. A Netmask may also be required. Check with the network administrator.
9. Follow the prompts to come back to the Setup Menu.
10. Select 1 to configure the RS232 channel.
11. Set up the following parameters as follows:
Baud Rate
Flow
Connect Mode
Flush Mode
Remote IP Address
12. Return to the Setup Menu and select 9 to save the settings.
13. Finally test the setup by connecting to the IP address using a Web browser or 'Pinging'.
14. From ACTWin Pro, enter the new IP address into the location manager for the site.
18-00026 Issue 4
ACT, Unit C1, South City Business Centre, Tallaght, Dublin 24, Ireland.
Unit 8 IDA Business Park, Whitestown, Tallaght, Dublin 24, Ireland.
Telephone: 353 1 462 2585. Telefax: 353 1 462 2587. E-mail: sales@actrl.com Web: www.actrl.com
Telephone: 353 1 466 2570
ACTLAN Interface Configuration
7
3 2
DB25 Male
(Rear View)
Connections for Direct Connect
1. Connect cable directly to
ACT1000/2000 and LAN device
2. In Communications Menu Set:
Address = 1
A
Direct Conn = Y
B
0V
DTR
RX
TX
RX = Pin 3
0V
TX = Pin 2
0V = Pin 7
TCP/IP Configuration
9600
C0
80
none
UK Lo-Call 0845-300 5204
LAN/WAN
7
22 21
DB25 Male
(Rear View)
Connections for Network
NETWORK
A
ACT 2000
I/F Mode
00
Disconnect Mode
Pack Control
Fax: 353 1 452 0427
15 14
ACTWin Pro Software
1. Connect LAN RS-485 cable to
NETWORK terminals on the
controller and LAN Interface
2. In ACT1000/2000 Communications
B 0V
Menu set the controller Address and
set Direct Conn = N
A
B
0V
Port
00
www.accesscontrol.ie
E-mail: sales@accesscontrol.ie
A = Pin 14
B = Pin 15
0V = Pin 7
Pin 14 = Pin 21
Pin 15 = Pin 22
4C for Direct
00

Advertisement

loading
Need help?

Need help?

Do you have a question about the ACTLAN - INTERFACE and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ACT ACTLAN - INTERFACE

  • Page 1 6. Enter the new IP address. 7. If the ACT controllers are on a different LAN segment to the ACTWin Pro PC, then a Gateway Address is required. Check with the network administrator for the IP address of the router.
  • Page 2 2. Insert Modem Direct Connect Cable and LAN RS-485 Cable (see below) inside Box 3. Insert 9-way to 25-way serial cable (ACT Part num 44-0005) 3. Seal Box and place ACT LAN Sticker outside Modem Direct Connect Cable NETWORK B 0V...