LG HB2350E Svc Manual page 19

Exploded view
Table of Contents

Advertisement

Check of power source.
Check of control switch
setting.
Only compressor fails to
start.
Drop of power voltage.
Defect of compressor
capacitor.
Check capacitor.
Replacement.
Irregular motor resistance ( )
Irregular motor insulation ( )
Replacement of compressor
(Motor damaged)
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
Fails to Start
Improper thermistor setting
Loose terminal connection.
Improper wiring
- 19 -
Check of circuit breaker
and fuse.
Check of control panel.
Only fan fails to start.
Improper wiring.
Defect of fan motor
capacitor.
Irregular motor resistance
(
).
Irregular motor insulation
(
).
Replacement of fan motor
Regular but fails to start
Replacement of compressor
(locking of rotor, metal)
LGE Internal Use Only