DEI PVM-4210 Operation Manual

950v pulse generator module

Advertisement

Quick Links

DEI PVM-4210
DIRECTED ENERGY, INC.
PVM-4210
±950V Pulse Generator Module

OPERATION MANUAL

Directed Energy, Inc.
2401 Research Blvd., Ste. 108
Fort Collins, Colorado 80526
970/493-1901
FAX 970/493-1903

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PVM-4210 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for DEI PVM-4210

  • Page 1: Operation Manual

    DEI PVM-4210 DIRECTED ENERGY, INC. PVM-4210 ±950V Pulse Generator Module OPERATION MANUAL Directed Energy, Inc. 2401 Research Blvd., Ste. 108 Fort Collins, Colorado 80526 970/493-1901 FAX 970/493-1903...
  • Page 2 DEI PVM-4210...
  • Page 3: Table Of Contents

    6.0 TROUBLESHOOTING ...11 6.1 Troubleshooting Procedures ...11 6.2 Factory Service ...12 7.0 WARRANTY ...12 APPENDIX...14 Mechanical Dimensions And Mounting Hole/Connector Location Drawing ...14 Document Number 9100-0201 Rev 8  Directed Energy, Inc. 2000-2002 Table Of Contents Page 1 DEI PVM-4210...
  • Page 4 ALL PERSONNEL WHO WORK WITH OR ARE EXPOSED TO THIS EQUIPMENT MUST TAKE PRECAUTIONS TO PROTECT THEMSELVES AGAINST POSSIBLE SERIOUS AND/OR FATAL Document Number 9100-0201 Rev 8  Directed Energy, Inc. 2000-2002 SYSTEM. practices. BODILY INJURY. Page 2 DEI PVM-4210...
  • Page 5: Safety

    <40 nanoseconds to DC. The pulser operates on +24VDC to +28VDC support power, and features integrated DC high voltage power supplies. The PVM-4210 is optimized for differential drive of deflection plates for electrostatic modulation spectrometers and accelerators. It will also drive any high impedance,...
  • Page 6 0 to 950V using screwdriver-adjustable potentiometers readily accessible on the end panel of the pulser module. The PVM-4210 requires +24VDC to +28VDC support power and a TTL (into 50 ) gate signal. For safety and control flexibility, a TTL level signal is used to enable and disable the DC power supplies.
  • Page 7  Directed Energy, Inc. 2000-2002 +24V To Logic +75V Power Supply Primary Drive Transformer Overcurrent Output Current Sense Sense +/- +24V Page 5 DEI PVM-4210 +950V Power Supply Positive Pull Positive Output Positive Pull Down Negative Pull Down Negative Output Negative Pull...
  • Page 8: Specifications

    CV capacitance, including the capacitance of the load, interconnect cable, and the internal capacitance of the PVM-4210, V is the pulse voltage, and F is the pulse repetition frequency (or the total pulses per second). (For these calculations, the internal capacitance of the PVM-4210 is 125pF, and Belden 8218 cable is 21.5pf/foot.) Given the maximum power supply capability of 4W (4mA) per...
  • Page 9: Connector Pin-Outs And User Adjustments

    20KHz. This formula is not applicable when driving non-capacitive (resistive or inductive) loads. Contact DEI for information or assistance in using the PVM-4210 with different load characteristics or impedances. 4.0 Connector Pin-Outs And User Adjustments...
  • Page 10 10 and 11 together. This is shown in the figure below: Document Number 9100-0201 Rev 8  Directed Energy, Inc. 2000-2002 Page 8 DEI PVM-4210...
  • Page 11: Power Supply Enable

    Output Pulse Configuration With Inverted Gate Selected 4.2 Power Supply Enable For safety and flexibility, the PVM-4210 features a power supply enable input (DSUB connector pin 14). In order to enable the DC power supplies (and therefore generate an output pulse), this input must be held HIGH. This can be done in two ways: 1.
  • Page 12: Operating Instructions

    5.1 Output Cabling The PVM-4210 is designed to drive capacitive loads with fast rise times. Since the current out of the PVM-4210 is limited, the lower the capacitance, the faster the risetime.
  • Page 13: Troubleshooting

    The table below summarizes potential problems and their solutions. If these recommendations do not resolve the problem, DEI customer service can be contacted for further assistance. SYMPTOM 1. No output pulse. Document Number 9100-0201 Rev 8  Directed Energy, Inc. 2000-2002 WARNING SOLUTIONS -No input trigger. Page 11 DEI PVM-4210...
  • Page 14: Factory Service

    10 &11 must be connected. -Output not connected correctly. Check all cables and connections. -Pulser is damaged. Contact DEI customer service. DIRECTED ENERGY, INC. 2401 RESEARCH BLVD SUITE 108 FORT COLLINS, CO 80526 (970) 493-1901 FAX (970) 493-1903 Page 12 DEI PVM-4210...
  • Page 15 DEI will be under no obligation to make any changes to product previously shipped. Document Number 9100-0201 Rev 8  Directed Energy, Inc. 2000-2002 Page 13 DEI PVM-4210...
  • Page 16: Appendix

    DEI PVM-4210 APPENDIX Mechanical Dimensions And Mounting Hole/Connector Location Drawing Document Number 9100-0201 Rev 8  Directed Energy, Inc. 2000-2002 Page 14...
  • Page 17 GATE RETURN (GROUND) 4.30 POWER SUPPLY ENABLE/DISABLE (TTL HIGH = ENABLED) +24-28VDC @ 600mA MAX 2.90 1.00 PVM-4210 Mechanical Dimensions And Mounting Hole/Connector Locations Document Number 9100-0201 Rev 8  Directed Energy, Inc. 2000-2002 11.50 10.50 PVM-4210 +/- 950V DUAL OUTPUT PULSER MODULE...