Side wall vent hood

Advertisement

INSTALLATION SAFETY INSTRUCTIONS
CAUTION: This device must be installed by a qualified installer in accordance with the manufacturer's installation
instructions and applicable codes.
1. Plan the vent system layout to avoid the possibility of accidental contact with concealed wiring or plumbing inside of
wall.
2. Single wall vent pipe may be used to join an appliance to the power venter; but, if proper clearance cannot be
maintained from combustible material or when passing through a side wall, Class "B" type vent pipe should be used
for gas appliances and Class "L" type vent pipe for oil appliances.
3. The power venter should be installed as close to the termination of the vent system as possible to reduce effects of
wind, outlet blockage and to guard against flue gas leakage. Vent pipe must be sealed on the positive pressure side
of the venter. Pipe joints and seams should be sealed with a high temperature silicone adhesive sealant or equivalent.
Test vent connections for leaks by using a soap solution as recommended by the National Fuel Gas Code: A.N.S.I.
Z223.1, Section 4.11.
4. Vent hood inlet diameter should never be smaller than the installed vent pipe.
INSTALLATION
1. Use inside wall end plate as a template to mark hole location. Cut hole 1/2 inch larger than marked hole to facilitate
easy installation.
2. Install vent hood through opening from outside. Fasten the vent hood to the outside wall with appropriate type
mounting screws.
3. Fasten wall end plate to the inside wall with appropriate type mounting screws.
4. Install a properly sized vent pipe section into inner pipe of the vent hood. Seal the connection and all other vent pipe
joints on the pressure side of the Power Venter with a high temperature silicone adhesive sealant or equivalent.
Fasten vent pipe connection with three sheet metal screws or with other appropriate type mounting screws.
MAINTENANCE
The vent system should be inspected regularly at 3-month intervals.
1. Screened opening of vent hood should be free from foreign material and cleaned if necessary.
2. Check all vent system connections for leakage and re-seal where necessary.
Please refer to the owners manual for complete system installation and safety instructions, multiple venting systems,
trouble shooting hints and maintenance instructions.