Microwave Hood Combination
PRODUCT MODEL NUMBERS
MH1140XM
MH1141XM
MH1150XM
Electrical: A 120-volt, 60-Hz, AC-only, 15- or 20-
amp. electrical supply located in the upper cabinet
as close as possible to the microwave oven hood.
A time-delay fuse or circuit breaker and separate
circuit is recommended.
VENTING REQUIREMENTS
Roof venting
roof cap
3-1/4" x 10"
through-the-roof
Recommended standard fittings
3-1/4" x 10"
3-1/4" x 10"
to 6" = 5 ft.
roof cap = 24 ft.
90 elbow
3-1/4" x 10"
45 elbow
= 10 ft.
wall cap =
= 5 ft.
40 ft.
If the existing vent is round, a rectangular-
to-round adapter must be used and a
rectangular 3" extension vent between the
damper assembly and the adapter must be
installed to prevent sticking of the exhaust
damper.
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
OVERALL DIMENSIONS
CABINET OPENING DIMENSIONS
NOTE: There must be
at least one wall stud
within cabinet
opening.
Wall venting
For wall or roof venting methods:
If the wall exhaust method is chosen, be sure that
there is proper clearance within the wall for the
exhaust vent.
Wall and roof caps must have back-draft damper.
We recommend:
using rigid metal vent.
3-1/4" x 10"
that length of vent and number of elbows should
90 elbow = 25 ft.
be kept to a minimum to provide efficient
performance.
that size of vent should be uniform.
using duct tape to seal all joints in the vent
system.
using caulking compound to seal exterior wall or
3-1/4" x 10"
flat elbow =
roof opening around cap.
10 ft.
two elbows should not be installed together.
We do NOT recommend:
flexible metal vent.
NOTE: If flexible metal vent must be used, calculate
each foot of flexible metal vent as two feet of rigid
metal vent. Flexible metal elbows count twice as
much as standard elbows.
16-1/4"
15-3/8"
30" min.
66" min.
to cooking
top of wall
surface
mounting plate
below
to floor
microwave
hood
wall cap
3-1/4" x 10"
through-the-wall
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
29-7/8"
12" to 14" recommended
cabinet depth
30" min. cabinet
opening width.
wall studs
Recommended vent length
Use 3-1/4" x 10" or 6" vent. The total length of the vent system
including straight vent, elbow, transitions, wall or roof caps
must not exceed the equivalent of 140 feet of
3-1/4" x 10" rectangular or 6" diameter round vent. For best
performance, use no more than three 90° elbows. To calculate
the length of system you need, add the equivalent feet for
each vent piece used in the system. See examples below.
3-1/4" x 10" vent system
3-1/4" x 10"
90° elbow
6 ft.
1 - 3-1/4" x 10"
2 ft.
90° elbow
1 - wall cap
8 feet straight
Length of
3-1/4" x 10" system
6" vent system
90° elbows
1 - transition
2 ft.
2 - 90° elbows
1 - wall cap
8 feet straight
Length of 6" system
transition
wall cap
= 25 ft.
= 40 ft.
= 8 ft.
= 73 ft.
6 ft.
= 5 ft.
= 20 ft.
= 40 ft.
= 8 ft.
= 73 ft.
Ref. 8184732
04-16-03