PCS61D/UC
!
For indoor use only.
For use on normally dry work surfaces only.
If any malfunction occurs, do not attempt to disassemble or
repair.
Allow enough clearance for part operation and function.
Avoid liquid spills into outlet.
Do not insert foreign objects into power outlets or USB ports.
Do not use provided screws on table thickness less than 1".
Use caution not to pierce top surface with mounting screws.
Plug into an appropriate outlet that is properly installed and
grounded in accordance with all local codes and regulations.
SPECIFICATIONS
6 ft. cord length.
USB-A & USB-C ports are for charging use only.
For edge mounting, the recommended table thickness is
1" MIN. to 1-1/2" MAX.
For under mounting, the recommended table thickness is
1" MAX.
Overcurrent reset switch is located on the back of the unit.
1
EDGE MOUNT
PCS61D/UC
Edge Mount Bracket
5/16" No. 8 -32 Thread
Flat-Head Machine Screw
Attach the edge mount bracket to the unit by using (2)
5/16" No. 8 -32 thread flat-head machine screw.
2025.05.15
WARNING
!
11/32"
C.T.C.
BOTTOM VIEW: EDGE MOUNT
1/2"
C.T.C.
TOP VIEW: UNDER MOUNT
9-13/16"
3X
3/16 DIA. HOLE
1-1/4" C.T.C.
1-1/4" C.T.C.
3X
3/16" DIA. HOLE
9-13/16"
2-15/16"
2
Work Surface
(Not Included)
Determine position and location of the unit on the edge of the
work surface. DO NOT place unit where cable is strained or
trapped.
1
TABLE OF CONTENTS
. . . . . . . . . . . 1X PCS61D/UC
. . . . . . . . . 1X Edge Mount Bracket
. . . . . . . . . . 1X Under Mount Plate
. . . . . . . 2X 5/16" No. 8 -32 Thread
Flat-Head Machine Screw
. . . . . . 3X 3/4" No. 10 Button-Head
2-15/16"
2-19/32"
1-5/32"
RIGHT VIEW: EDGE MOUNT
4-7/32"
2-5/8"
RIGHT VIEW: UNDER MOUNT
Wood Screw
Need help?