Welcome to the Hunter Stoves family and thank you for purchasing an Aspect Eco stove. This stove was designed and built to be a high-performance heating appliance, and we hope it will bring you great enjoyment. The natural environment is important to us, so our stoves are manufactured to provided you with a clean and efficient burn that will keep you warm through cold winter nights.
SAFETY INFORMATION WARNING: THE APPLIANCE AND FLUE SYSTEM SHOULD BE INSTALLED IN ACCORDANCE WITH AS/NZS 2918 AND THE APPROPRIATE REQUIREMENTS OF THE RELEVANT BUILDING CODE OR CODES. WARNING APPLIANCES INSTALLED IN ACCORDANCE WITH A AS/NZS 2918 SHOULD CONFORM TO THE REQUIREMENTS OF AS/NZS 4013 AND AS/NZS 4012 WHERE REQUIRED BY THE REGULATORY AUTHORITY, THAT IS THE APPLIANCE SHOULD BE IDENTIFIABLE BY CONFORMANCE PLATE WITH THE MARKING ‘TESTED TO A AS/NZS 4013 AND AS/NZS 4012’...
Any air opening must be kept clear from blockage or obstruction. Hunter Stoves recommends using 6” flue pipe up the Adequate air supply is required for any wood stove. entire chimney where possible.
470mm on Legs (Standard) Minimum Hearth on Legs - 845mm deep x 770mm wide x 42mm thick* RRP $3749 Hearth Requirements Aspect 5 When Installed with Hunter Stoves plinth or bench options RRP $3149 RRP $4225 Aspect 5 Answer 11.8KW...
FLUE REQUIREMENTS * Flue Kit Options This appliance is approved with a 6” triple skin flue kit with 8” solid casing and tested in two positions in a manner conforming to joint Australian/New Zealand Standard 2918:2018, Appendix B. The flue kit and heat shields chosen will affect the rear wall clearance. 250mm Rear Wall Clearance Use default triple skin flue kit with 8”...
Page 10
FLUE REQUIREMENTS Standard 6” - 10” Triple Skin Flue Kit Installation - 8” Solid Heat Shield This appliance is approved with a 6” triple skin flue kit with 8” solid casing and tested in two positions in a manner conforming to joint Australian/New Zealand Standard 2918:2018, Appendix B.
Page 11
FLUE REQUIREMENTS Standard 6” - 10” Triple Skin Flue Kit Installation - 8” Solid Heat Shield & Inner Shield Reduced Rear Wall Clearance When installed with Appliance Heat Shield & 900mm high x 180° stainless steel rear flue shield fitted between the solid 8” flue & 6” active flue. Cowl Flashing Triple Skin...
Page 12
FLUE REQUIREMENTS Standard 6” - 10” Triple Skin Flue Kit Installation - Double Half Heat Shield Reduced Rear Wall Clearance When installed with Appliance Heat Shield & Double 900mm high x 180° stainless steel half heat shield fitted between the 6” active flue & rear wall. Cowl Flashing Triple Skin...
Page 13
FLUE REQUIREMENTS Approved 6” - 8” Insulated Flue Kit - With Half Heat Shield Reduced Rear Wall Clearance When installed with Appliance Heat Shield & Approved Insulated Flue Kit installed with 900mm high x 180° stainless steel half heat shield fitted between the 8”...
GENERAL GUIDANCE Unpacking and Removing Internal Components After unpacking all internal components must be removed prior to fitting the stove. This will make handling the stove easier; allow access to fixings and the flue outlet; as well as protect the internal components from damage during the installation process.
Page 15
Appliance Heat Shield Baffles - Removal Heat Shield shown in shipping position. Lift the brick baffle and slide to one side and allow the If installing the rear appliance heat shield to reduce other side to drop down into firebox (supporting at all rear wall clearances.
Health and Safety Guidance Special care must be taken when installing the stove such that the requirements of the Health and Safety at Work Act are met. Handling This appliance is very heavy. Adequate facilities must be available for loading, unloading and side handling. Fire Cement Some types of fire cement are caustic and should not be allowed to come into contact with the skin.
This is necessary for lighting the stove. Lighting the Stove Hunter Stoves recommends the top down lighting method for a cleaner and more convenient start. Ensure the air control is in the fully open position, and the internal grate is fully closed.
Adding Wood Only refuel when fire has died down to embers. Ensure that the wood you are using has a moisture content of less than 18% (we recommend 12-15% to ensure an efficient burn). When refuelling open all the air controls fully and the damper (if fitted). Open the door slowly by releasing the handle and allowing to stay like this for 5 to 10 seconds.
If the rope is in poor condition, a replacement rope kit may be ordered from the Hunter Stoves Group spares range. Gasket Tape The glass gasket tape (3) will have to be replaced when a new piece of glass (4) is fitted as the self-adhesive tape is stuck onto the glass.
Painted Finish – The finish can be renovated with Hunter Stoves paint. available through your closest Hunter Stoves outlet. All spare parts can be through you closest Hunter Stoves outlet See www.hunterstoves.com.au for your closest outlet...
Recommended Fuels Hunter Stoves Group recommend that only hardwood logs with a moisture content of less than 18% should be burnt on this appliance. Burning wet or unseasoned wood will create excess smoke emissions, tar deposits in the stove and chimney and will not produce a satisfactory heat output.
Aerosols Do not use an aerosol spray on or near the stove when it is alight. Operating The Stove Warning! – This Appliance will be hot when in operation and due care should be taken. We advise that suitable gloves, or the operating tool is used when operating the air control, and when opening the door.
TROUBLESHOOTING Smoke This can happen for a variety of reasons e.g cold air trapped in chimney/flue. As cold air is denser, this causes smoke to be forced back down the chimney. We recommend trying to heat the chimney before lighting for example, placing a fire-lighter on top of the kindling.
This is needed in the event of a claim during the warranty period. Only genuine Hunter Stoves spare parts or consumables can be used in the servicing and maintenance of the appliance during any standard or extended warranty period. These can be sourced from your authorised supplier directly.
Page 25
Cost associated with the removal and re-installation of an appliance subject to a warranty claim. Dragon Wholesaling Pty Ltd & Hunter Stoves Group total liability will only extend to the total purchase price paid for the goods in any warranty claim. We reserve the right to replace, repair or refund to value of goods purchased.
Page 26
Distributed in Australia by Dragon Wholesaling Pty Ltd www.hunterstoves.com.au Email: info@hunterstoves.com.au Hunter Stoves Ltd (UK) 8 Emperor Way, Exeter Business Park, Exeter, Devon, EX1 3QS Hunter Stoves reserve the right to change dimensions and procedures described in these instructions at anytime without special notice.
Need help?
Do you have a question about the Parkray ASPECT 5 ECO and is the answer not in the manual?