DATAEAGLE Compact 473 Series Manual

Wireless ethernet
Table of Contents

Advertisement

Quick Links

Manual
DATAEAGLE 4000 Series - Wireless
ETHERNET
Schildknecht AG
28. Februar 2023
Schildknecht AG
Haugweg 26
D-71711 Murr
Tel.: +49 (7144) 89718 0
Mail:
info@schildknecht.ag

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Compact 473 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for DATAEAGLE Compact 473 Series

  • Page 1 Manual DATAEAGLE 4000 Series - Wireless ETHERNET Schildknecht AG 28. Februar 2023 Schildknecht AG Haugweg 26 D-71711 Murr Tel.: +49 (7144) 89718 0 Mail: info@schildknecht.ag...
  • Page 2 Manual DATAEAGLE 4000 Series - Wireless ETHERNET...
  • Page 3 DATAEAGLE Compact 4343 11158 DATAEAGLE X-treme 4343 11374 DATAEAGLE Compact 473x 15475 DATAEAGLE X-treme 473x 15476 Version Language Date 28. Februar 2023 Schildknecht AG Haugweg 26 D-71711 Murr Tel.: +49 (7144) 89718 0 Mail: info@schildknecht.ag Manual DATAEAGLE 4000 Series - Wireless ETHERNET...
  • Page 4: Table Of Contents

    3.2 Operating principle DATAEAGLE 4000 ....3.3 DATAEAGLE Compact ......
  • Page 5 8.1 DATAEAGLE Compact 4715 - Article number: 11170 ..8.2 DATAEAGLE X-treme 4715 - Article number: 11420 ..46 8.3 DATAEAGLE Compact 4713 - Article number: 11171 ..
  • Page 6: Introduction

    It instructs not on the safe use of the machine in which the devices are or will be integrated. Information on this can be found in the operating instructions for the machine. Manual DATAEAGLE 4000 Series - Wireless ETHERNET...
  • Page 7: Trademark

    In this documentation the trademarks of the following companies and institutions are used: PROFINET PROFIBUS Nutzerorganisation e.V. (PNO) PROFIsafe PROFIBUS Nutzerorganisation e.V. (PNO) EtherNet/IP Open DeviceNet Vendor Association, Inc (ODVA) openSAFETY Ethernet POWERLINK Standardization Group(EPSG) Manual DATAEAGLE 4000 Series - Wireless ETHERNET...
  • Page 8: For Your Safety

    2 For your safety 2 For your safety → Read this chapter carefully. → Only then work with the DATAEAGLE module. 2.1 General safety instructions ATTENTION! High electrical voltage in the machine / plant. Death or serious injury due to electric shock.
  • Page 9: Intended Use

    EN 60529 for protection class IP20 (Compact) or IP65 (X-treme) and can be used in control cabinets up to protection class IP67. The DATAEAGLE may only be used for the cases provided for in the operating instructions and manual and only in conjunction with the third-party devices and components recommended or approved by Schildknecht AG.
  • Page 10: Environmentally Friendly Disposal

    The product can be returned to Schildknecht AG in case of disposal. This also applies to the original packaging and any batteries or rechargeable batteries. Devices contaminated with hazardous substances will not be taken back for repair or disposal. Manual DATAEAGLE 4000 Series - Wireless ETHERNET...
  • Page 11: Ce Declaration Of Conformity

    2.5 Warranty and liability claims Warranty and liability claims are lost if • the product is not used as intended, • damage is due to failure to observe the operating instructions, • the staff was/is not knowledgeable. Manual DATAEAGLE 4000 Series - Wireless ETHERNET...
  • Page 12: Description

    3 Description 3 Description 3.1 Introduction The modules of the DATAEAGLE 4000 series have been specially developed for the transmission of Ethernet via radio. Depending on the device type, transmission has been optimised for Ethernet, PROFINET, PROFIsafe, EtherNet/IP and openSAFETY via UDP. Some device variants are multi-protocol compliant.
  • Page 13: Dataeagle Compact

    Power supply Clamps Description 24 V DC Switching output USB port DATAEAGLE Compact has a USB port for configuration and software updates via the DATAEAGLE Wizard tool. Antenna connection SMA connector for antenna Ethernet Interface 2 x RJ45 (integrated Switch) 10/100 MBit Ethernet...
  • Page 14: Leds

    On/Blinking Radio connection(s) active Radio Connection(s) inactive STAT LED Anzeige Zustand Beschreibung STAT On (Master) no Ethernet connection Blinking Ethernet error detected (Master) no Error detected For more information, check the device diagnostics. Manual DATAEAGLE 4000 Series - Wireless ETHERNET...
  • Page 15: Dataeagle X-Treme

    3 Description 3.4 DATAEAGLE X-treme 3.4.1 Connections Power supply M12, A-coded, 5 pin (male) Description +24 VDC not connected not connected Ethernet Interface M12, D-coded, 4 pin (female) Description Manual DATAEAGLE 4000 Series - Wireless ETHERNET...
  • Page 16: Leds

    3 Description USB port The DATAEAGLE X-treme has a USB port for configuration and software updates via the DATAEAGLE Wizard tool. This is located behind the PG screw. Antenna connection SMA connector for antenna 3.4.2 LEDs ON LED Indication State...
  • Page 17 On (Master) no Ethernet connection Blinking Ethernet error detected (Master) no Error detected For more information, check the device diagnostics. LINK LED Indication State Description LINK Yellow On/Blinking Ethernet connection(s) active Ethernet Connection(s) Manual DATAEAGLE 4000 Series - Wireless ETHERNET...
  • Page 18: Mounting

    • Suitable mounting location with regard to vibration and shock load, temperature and humidity (see ”4. Technical data” ) • Protected to prevent disconnection of the connecting cables by personnel or equipment. • Diagnostic LEDs of the device can be viewed during operation Manual DATAEAGLE 4000 Series - Wireless ETHERNET...
  • Page 19: Dimensions

    4 Mounting 4.2 Dimensions DATAEAGLE Compact Dimensions in mm DATAEAGLE X-treme Dimensions in mm Manual DATAEAGLE 4000 Series - Wireless ETHERNET...
  • Page 20: Mounting The Components

    → Fasten the module at the designated place according to its fastening type. Mount: 1. Place the module from diagonally above onto the top-hat rail. 2. Press the module down firmly. The foot latch engages. The unit is firmly seated on the top-hat rail. Example: Manual DATAEAGLE 4000 Series - Wireless ETHERNET...
  • Page 21 → Attach the module to the designated location according to its mounting method. Mount: 1. If necessary, drill holes for mounting according to the enclosed drilling template → https://www.schildknecht.ag/download/x-treme-drill-template- bohrschablone/. 2. Screw the device tightly. Manual DATAEAGLE 4000 Series - Wireless ETHERNET...
  • Page 22: Mounting The Antennas

    Tighten the screw connections of the antennas or antenna cables only hand- tight. FURTHER NOTES ON ANTENNA INSTALLATION! You will find further information on antenna mounting and alignment in our Antenna 101 → https://lp.schildknecht.ag/en/whitepaper-antenna101 Manual DATAEAGLE 4000 Series - Wireless ETHERNET...
  • Page 23: Disassembly And Module Replacement

    2. Unscrew the antenna cable/antenna. Remove module (See assembly of the module) Mount new module (See assembly of the module) 1. Mount the new module. 2. Connect the wires to the new module (See Connection power supply). Manual DATAEAGLE 4000 Series - Wireless ETHERNET...
  • Page 24: Installation

    Electromagnetic interference may occur if rated operating voltages other than 24 V DC of the SELV (safety extra low voltage) category are used. → Only use power supplies that comply with the SELV category. →Note technical data Manual DATAEAGLE 4000 Series - Wireless ETHERNET...
  • Page 25 5 Installation Power supply - DATAEAGLE Compact Clamps Description 24 V DC Switching output Power supply - DATAEAGLE X-treme M12, A-coded, 5 pin (male) Description +24 VDC not connected not connected Manual DATAEAGLE 4000 Series - Wireless ETHERNET...
  • Page 26: Ethernet Connection

    5 Installation 5.2 Ethernet connection Ethernet - DATAEAGLE Compact 2 x RJ45 (integrated Switch) 10/100 MBit Ethernet Ethernet - DATAEAGLE X-treme M12, D-coded, 4 pin (female) Description Manual DATAEAGLE 4000 Series - Wireless ETHERNET...
  • Page 27: Commissioning

    NOTE New devices are preconfigured at the factory. In the delivery state, the units are configured as a radio network. The Ethernet participants/connections that are connected after the radio link are automatically detected. Manual DATAEAGLE 4000 Series - Wireless ETHERNET...
  • Page 28: Configuration Filtertime

    (Download Link) - Installed on PC • USB cable - between PC and DATAEAGLE Connect DATAEAGLE to the PC via the USB cable and start the DATAEAGLE Wizard configuration software. Select Autodetect COM Port and then Connect to connect to DATAEAGLE and read the configuration.
  • Page 29 A too high configured filter time can lead to a delayed shutdown reaction of the connected devices in case of an error. Therefore, please check whether the system with the set filter time matches the required reaction speed. Manual DATAEAGLE 4000 Series - Wireless ETHERNET...
  • Page 30: Configuration Radio Parameters

    • DATAEAGLE Wizard configuration tool - installed on PC • USB cable - between PC and DATAEAGLE Connect DATAEAGLE to the PC via the USB cable and start the DATAEAGLE Wizard configuration software. Select Connect to connect to DATAEAGLE and read the configuration. The DATAEAGLE must be switched on for this.
  • Page 31 Master has the station address 01 and the partner addresses 02 and 03. Slave 1 has the station address 02 and the partner address 01. Slave 2 has the station address 03 and the partner address 01. Manual DATAEAGLE 4000 Series - Wireless ETHERNET...
  • Page 32: 2,4 Ghz Bluetooth - Dataeagle Compact/X-Treme 471X

    6 Commissioning 6.3.1 2,4 GHz Bluetooth - DATAEAGLE Compact/X-treme 471x Select in the menu tree: Interface → Radio → Bluetooth NOTE If a radio system was ordered as a set (set configuration), no change is necessary here. The Bluetooth MAC address must be read out at the master and entered at the slave.
  • Page 33: 2,4 Ghz Bluetooth 5 - Dataeagle Compact/X-Treme 473X

    6 Commissioning 6.3.2 2,4 GHz Bluetooth 5 - DATAEAGLE Compact/X-treme 473x Select in the menu tree: Interface → Radio → Bluetooth LE NOTE If a radio system was ordered as a set (set configuration), no change is necessary here. The Bluetooth MAC address must be read out at the slave and entered at the master.
  • Page 34: 869 Mhz - Dataeagle Compact/X-Treme 433X

    6 Commissioning 6.3.3 869 MHz - DATAEAGLE Compact/X-treme 433x NOTE If a radio system was ordered as a set (set configuration), no change is necessary here. Select in the menu tree: Interface → Radio → 869 MHz Manual DATAEAGLE 4000 Series - Wireless ETHERNET...
  • Page 35 All devices in a radio system must be set to the same radio channel. DATAEAGLE radio systems in parallel operation are to be operated with different radio channels! However, it should be noted that at high RF rate only 1...
  • Page 36: 915 Mhz - Dataeagle Compact/Xtreme 434X

    6 Commissioning 6.3.4 915 MHz - DATAEAGLE Compact/Xtreme 434x NOTE If a radio system was ordered as a set (set configuration), no change is necessary here. Select in the menu tree: Interface → Radio → 900 MHz Manual DATAEAGLE 4000 Series - Wireless ETHERNET...
  • Page 37 All devices in a radio system must be set to the same radio channel. DATAEAGLE radio systems in parallel operation are to be operated with different radio channels! It makes sense to reduce the transmitting power in order not to influence...
  • Page 38: Diagnosis

    The integrated UDP diagnostic slave can be used to monitor the radio link and the connected fieldbus devices. In order to access the data of the diagnostic slave, an IP address and a UDP port must be configured on the DATAEAGLE master for the diagnostic slave. Manual...
  • Page 39 6 Commissioning To do this, connect DATAEAGLE to the PC via the USB cable and start the DATAEAGLE Wizard configuration software. Select Autodetect COM Port and then Connect to connect to DATAEAGLE and read the configuration. The DATAEAGLE must be switched on for this.
  • Page 40: Diagnostic Via Terminal Mode

    6 Commissioning 6.4.2 Diagnostic via terminal mode A diagnosis is also possible via the terminal function of the DATAEAGLE Wizard. The following steps are necessary for this. In the DATAEAGLE Wizard, use the ”Tools” menu to select ”Terminalmode”. A new window opens. Check the COM port and select ”Connect”.
  • Page 41: Tips And Tricks

    → Always use shielded cables for interfaces and power supplies. → Use shielding braid with a density of at least 85 %. → Always connect the shield on both sides to the EMC ground (usually PE). Bus and power lines Manual DATAEAGLE 4000 Series - Wireless ETHERNET...
  • Page 42 Electronic or electrical components without a closed metal housing are a source of interference for RF fields. → Make sure that all electronic or electrical components that could be a source of interference from RF fields have a closed metal housing. Manual DATAEAGLE 4000 Series - Wireless ETHERNET...
  • Page 43: Optimal Antenna Mounting

    → Route protective conductors of the individual system components in a star configuration to the equipotential bonding rail. 7.2 Optimal antenna mounting Instructions for antenna mounting and alignment can be found in our Antenna 1x1 → https://www.schildknecht.ag/download/antennen-1mal1/ Manual DATAEAGLE 4000 Series - Wireless ETHERNET...
  • Page 44: Technical Data

    • The device may only be connected by an electrician in accordance with IEC 60364! • No direct connection of these devices to other networks! • Observe five safety rules! See chapter 2.1 Manual DATAEAGLE 4000 Series - Wireless ETHERNET...
  • Page 45: Dataeagle Compact 4715 - Article Number: 11170

    8 Technical data 8.1 DATAEAGLE Compact 4715 - Article number: 11170 General Power supply 24 V DC Power supply connection terminals Power consumption 100mA Protection class IP20 Temperature range -20...+60 °C Conformity CE, FCC, IC Weight 130g Wide 22,5 mm...
  • Page 46: Dataeagle X-Treme 4715 - Article Number: 11420

    8 Technical data 8.2 DATAEAGLE X-treme 4715 - Article number: 11420 General Power supply 24 V DC Power supply connection M12, A-coded, 5 pin (male) Power consumption 100mA Mounting 4-hole screw mounting Protection class IP65 Temperature range -20...+60 °C Conformity...
  • Page 47: Dataeagle Compact 4713 - Article Number: 11171

    8 Technical data 8.3 DATAEAGLE Compact 4713 - Article number: 11171 General Power supply 24 V DC Power supply connection terminals Power consumption 100mA Protection class IP20 Temperature range -20...+60 °C Conformity CE, FCC, IC Weight 130g Wide 22,5 mm...
  • Page 48: Dataeagle X-Treme 4713 - Article Number: 11421

    8 Technical data 8.4 DATAEAGLE X-treme 4713 - Article number: 11421 General Power supply 24 V DC Power supply connection M12, A-coded, 5 pin (male) Power consumption 100mA Mounting 4-hole screw mounting Protection class IP65 Temperature range -20...+60 °C Conformity...
  • Page 49: Dataeagle Compact 4712 - Article Number: 11174

    8 Technical data 8.5 DATAEAGLE Compact 4712 - Article number: 11174 General Power supply 24 V DC Power supply connection terminals Power consumption 100mA Protection class IP20 Temperature range -20...+60 °C Conformity CE, FCC, IC Weight 130g Wide 22,5 mm...
  • Page 50: Dataeagle X-Treme 4712 - Article Number: 11422

    8 Technical data 8.6 DATAEAGLE X-treme 4712 - Article number: 11422 General Power supply 24 V DC Power supply connection M12, A-coded, 5 pin (male) Power consumption 100mA Mounting 4-hole screw mounting Protection class IP65 Temperature range -20...+60 °C Conformity...
  • Page 51: Dataeagle Compact 4710 - Article Number: 11175

    8 Technical data 8.7 DATAEAGLE Compact 4710 - Article number: 11175 General Power supply 24 V DC Power supply connection terminals Power consumption 100mA Protection class IP20 Temperature range -20...+60 °C Conformity CE, FCC, IC Weight 130g Wide 22,5 mm...
  • Page 52: Dataeagle X-Treme 4710 - Article Number: 11423

    8 Technical data 8.8 DATAEAGLE X-treme 4710 - Article number: 11423 General Power supply 24 V DC Power supply connection M12, A-coded, 5 pin (male) Power consumption 100mA Mounting 4-hole screw mounting Protection class IP65 Temperature range -20...+60 °C Conformity...
  • Page 53: Dataeagle Compact 4333 - Article Number: 11144

    8 Technical data 8.9 DATAEAGLE Compact 4333 - Article number: 11144 General Power supply 24 V DC Power supply connection terminals Power consumption 100mA Protection class IP20 Temperature range -20...+60 °C Conformity Weight 160g Wide 22,5 mm Height 99 mm...
  • Page 54: Dataeagle X-Treme 4333 - Article Number: 11327

    8 Technical data 8.10 DATAEAGLE X-treme 4333 - Article number: 11327 General Power supply 24 V DC Power supply connection M12, A-coded, 5 pin (male) Power consumption 100mA Mounting 4-hole screw mounting Protection class IP65 Temperature range -20...+60 °C Conformity...
  • Page 55: Dataeagle Compact 4343 - Article Number: 11158

    8 Technical data 8.11 DATAEAGLE Compact 4343 - Article number: 11158 General Power supply 24 V DC Power supply connection terminals Power consumption 100mA Protection class IP20 Temperature range -20...+60 °C Conformity Weight 160g Wide 22,5 mm Height 99 mm...
  • Page 56: Dataeagle X-Treme 4343 - Article Number: 11374

    8 Technical data 8.12 DATAEAGLE X-treme 4343 - Article number: 11374 General Power supply 24 V DC Power supply connection M12, A-coded, 5 pin (male) Power consumption 100mA Mounting 4-hole screw mounting Protection class IP65 Temperature range -20...+60 °C Conformity...
  • Page 57: Dataeagle Compact 473Xa - Article Number: 15475

    8 Technical data 8.13 DATAEAGLE Compact 473xA - Article number: 15475 General Power supply 24 V DC Power supply connection terminals Power consumption 100mA Protection class IP20 Temperature range -20...+60 °C Conformity CE, FCC, IC Weight 130g Wide 22,5 mm...
  • Page 58: Software Feature Ethernet Multipoint - Article Number: 15480

    UDP Max. Number participants/connections Safety communication 8.13.5 Software Feature Multiprotokoll Safe Multipoint - Article number: 15483 Max. Number of radio slaves Optimized for PROFINET, EtherNet/IP, openSAFETY via UDP Max. Number participants/connections Safety communication Manual DATAEAGLE 4000 Series - Wireless ETHERNET...
  • Page 59: Dataeagle X-Treme 473Xa - Article Number: 15476

    8 Technical data 8.14 DATAEAGLE X-treme 473xA - Article number: 15476 General Power supply 24 V DC Power supply connection M12, A-coded, 5 pin (male) Power consumption 100mA Mounting 4-hole screw mounting Protection class IP65 Temperature range -20...+60 °C Conformity...
  • Page 60: Software Feature Ethernet Multipoint - Article Number: 15480

    UDP Max. Number participants/connections Safety communication 8.14.5 Software Feature Multiprotokoll Safe Multipoint - Article number: 15483 Max. Number of radio slaves Optimized for PROFINET, EtherNet/IP, openSAFETY via UDP Max. Number participants/connections Safety communication Manual DATAEAGLE 4000 Series - Wireless ETHERNET...
  • Page 61: Legal Notice

    For this reason, the customer is also obliged Manual DATAEAGLE 4000 Series - Wireless ETHERNET...
  • Page 62 Schildknecht AG have been integrated into the advertised products of the customer.The customer shall, when using trademarks of Schildknecht AG, indicate in a suitable manner that these are trademarks of Schildknecht AG. Manual DATAEAGLE 4000 Series - Wireless ETHERNET...

Table of Contents