GMX260 & 560 Compact Weather Stations Table of Contents Welcome to the MaxiMet Marine user manual..............4 1.1. Overview of Content........................4 1.2. Description of Icons ........................4 1.3. General Notes ..........................5 1.4. User Manual Revision History ....................... 5 Product Overview and Functions ..................
Page 3
Appendix G - Configuring MaxiMet for SDI-12 ................ 64 Appendix H - Safe Mode ......................71 Appendix I - Using a Terminal Program to run MaxiMet Marine Tilt function ......78 Appendix J - Using a Terminal Program to set MaxiMet Date and Time ......... 80 Appendix K - Using Gill MetView Software to View the MaxiMet Data String ......
1. Welcome to the MaxiMet Marine user manual. About this manual This manual provides the information needed to get the best results from MaxiMet Marine The most recent version of this manual is available at gillinstruments.com. Please read this manual before setting up and installing MaxiMet Marine 1.1.
GMX260 & 560 Compact Weather Stations 1.3. General Notes Before MaxiMet Marine is used for the first time it is essential to read and understand this manual. Please keep the manual safe for future reference. Care should be taken with MaxiMet Marine at all times. The product should be transported to site in the box, and only removed when ready to install.
GMX260 & 560 Compact Weather Stations 2. Product Overview and Functions The Gill MaxiMet Marine is a very robust device with no moving parts. The units of measure, output rate and Communication formats are all user selectable. The MaxiMet Marine can be used in conjunction with a PC, data logger or other device.
True wind – wind speed and/or direction information corrected by GPS for any direction misalignment of the north marker and/or for any motion of the station. (E.g. vehicle or vessel). Note: 6 axis compass only corrects for compass accuracy when the MaxiMet Marine is tilted – it does not correct measured wind direction accuracy.
MaxiMet Marine uses the internal compass to electronically sense the horizontal component of the Earths’ magnetic field. Information from the compass can be used to correct the Wind direction data for when the MaxiMet Marine is not aligned to North. The output of the wind direction is relative to magnetic North. The MaxiMet Marine compass is calibrated at Gill Instruments before the unit is delivered.
GMX260 & 560 Compact Weather Stations 2.8. Inclinometer (GMX260 & GMX560) MaxiMet Marine outputs Tilt co-ordinates X and Y in terms of degrees and Z in terms of orientation. Normal Tilt Output • X-Tilt is displayed in degrees with 2 signed integral digits over the range ±89⁰.
Product Test Report. 3.2. Optional Extras/Spares A range of accessories is available to support MaxiMet Marine A list of accessories is shown below. More information, and the most up to date list of accessories can be found at gillinstruments.com. Accessory...
3.5. Packaging Whilst the MaxiMet Marine is being moved to its installation site, the unit should be kept in its inner packaging. All the packaging should be retained for use if the unit has to be returned at any time, or if a self-test is performed.
Do NOT mount the MaxiMet Marine in close proximity of high-powered radar or radio transmitters. A site survey may be required if there is any doubt about the strength of external electrical noise.
The boom should be positioned on the prevailing wind side of the tower. It is important to ensure that the MaxiMet Marine is mounted in a position clear of any structure which may obstruct the airflow or induce turbulence.
GMX260 & 560 Compact Weather Stations 4.4. GPS MaxiMet should be mounted horizontally and vertically as level as possible. MaxiMet Marine has a tilt sensor output that can assist with this. A clear view of the sky is best for an optimal satellite lock. Tree canopy, surrounding hills/mountains, tall buildings and any mounting structure/mast that obscures the view either overhead or of the horizon can impede reception.
Page 15
GMX260 & 560 Compact Weather Stations 4.8. Installing MaxiMet Marine on pipe or pole End Pole Mounting Arrangement STEP 1: Mount Adaptor (4856-30-003) to Bracket (4856-30-001) using 3 off M5 16mm screws (032-07079), 6 off M5 washers (032-07122) & 3 off M5 Nyloc nuts (032-03729). Torque tighten nuts to 3Nm+/-0.3.
Page 17
GMX260 & 560 Compact Weather Stations Side Pole Mounting Arrangement STEP 1: Mount Adaptor (4856-30-003) to Bracket (4856-30-001), using 3 off M5 16mm screws (032-07079), 6 off M5 washers (032-07122) & 3 off M5 Nyloc nuts (032-03729). Torque tighten nuts to 3Nm+/-0.3. STEP 2: Secure bracket and pole mount support plate (4856-30-004) to pole using 2off supplied M6 V-Bolts (032-07120), 4 off M6 washers (032-07176) &...
GMX260 & 560 Compact Weather Stations 4.9. Installing Cable Strain Relief Once MaxiMet Marine has been affixed in place, all cables should be secured: • With cable clamps or equivalent such that the connector does not support the cable weight.
The pin allocation for the power and communications connector is shown below. It is recommended that: • MaxiMet Marine default factory communications setting is RS232 • Any cable wires not used should be isolated and grounded at the terminating equipment/user end.
GMX260 & 560 Compact Weather Stations 6. Maintain MaxiMet 6.8. Safe Mode If the unit will not communicate, or the communication protocol settings are not known, then communications with the unit can be established using Safe Mode. Details of how to use Safe Mode can be found in Appendix H.
GMX260 & 560 Compact Weather Stations Appendix A - Technical Specification Wind Measurement Parameters Polar Wind Speed & Direction or U and V Vectors Wind Speed Range 0.01 to 60m/s Accuracy 0-10 m/s 0.3 m/s RMSE 10-40 m/s 3% RMSE 40-60 m/s 5% RMSE Resolution 0.01m/s...
Page 24
Real Time Clock Format Date and Time YYYY-MM-DDThh:mm:ss.s, e.g. 2014-12-25-T22:34:56.1 Updating Manual setting or via GPS option Power Loss Accuracy ±10 seconds for at least 24 hours after power removed from MaxiMet Compass Range 0-359.9° Resolution Compass Heading 0.1° Units of Measure...
Page 25
GMX260 & 560 Compact Weather Stations Power Supply Input Voltage (RS232, RS422, RS485) 5V to 30V DC 10 to 30VDC (with heating) Average Current at 12V DC with 28mA Power Saving Mode disabled For GPS-enabled units allow for an additional 10mA For Heated enabled units allow for 400mA (default) Average Current at 12V DC in Power...
GMX260 & 560 Compact Weather Stations Appendix B - Default Configuration GMX260 Factory Default Data String Items in red relate to the GPS option unit. NODE, DIR, SPEED, CDIR, CSPEED, GPSLOCATION, TIME, VOLT, STATUS, CHECK ┐Q,021,000.01,090,000.01,+50.763004:-001.539898:+3.10,2015-06-05T10:19:30.8, +05.1,0000,└ 36 Where:- ┐ Node Letter Wind Direction 000.01...
Page 28
GMX260 & 560 Compact Weather Stations GMX560 Factory Default Data String Factory Default Data String Items in red relate to the GPS option unit. Items in green relate to Heater option unit. NODE, DIR, SPEED, CDIR, CSPEED, PRESS, RH, TEMP, DEWPOINT, GPSLOCATION, TIME, VOLT, HEATSTAT, STATUS, CHECK ┐Q,021,000.01,090,000.01,1015.3,041, +022.0, +008.5,+50.763004:-001.539898:+3.10,2015-06- 05T10:19:30.8,+05.1,0000,0004,└...
Page 29
GMX260 & 560 Compact Weather Stations MetSet Default Settings REPORT : NODE DIR SPEED CDIR CSPEED PRESS RH TEMP DEWPOINT GPSLOCATION TIME VOLT STATUS CHECK PROTOCOL : GILL SENSOR COMPASS : ON POWER : 0 COMMS : RS232 COMPASSDECL : +000.0 TIME : 2015-06-05T11:04:54 BAUD : 19200 SENSOR GPS : ON...
Install MetSet software (V2.17.01 or higher) on to a PC from the Gill website at: http://gillinstruments.com/main/software.html Before you use MetSet check that MaxiMet Marine is correctly connected to a serial COM port or USB COM port on your PC (maximum COM port number accepted by MetSet is 50).
Page 34
GMX260 & 560 Compact Weather Stations MetSet also saves a copy of the screen below as a Session Report File that can be accessed at the following destination: C:\GillAppsData\Metset\SessionReports. Example Summary of MaxiMet Device Settings gillinstruments.com Document Number: 1957-PS-029 Iss 3...
Page 35
When connected correctly a MetSet editing screen is available to read configuration settings, change configuration settings, save MaxiMet Marine configuration settings to a PC file location, upload MaxiMet Marine configuration settings from a PC file and view the MaxiMet Marine raw data string output.
ONLINE in green indicates the MaxiMet has been successfully connected to MetSet. ONLINE OFFLINE in grey indicates that MetSet is being used without a MaxiMet in communication with MetSet. 4800 is a report on the MaxiMet baud rate setting. 4800 COM23 COM 23 is a report on the MaxiMet COM port connection number.
Page 37
When Comms or Baud Rate settings are changed and saved to the device a warning is issued by MetSet. These setting changes will not become active until the MaxiMet Marine power is turned off and turned on again. The connecting device will then also need its Comms and Baud Rate settings changed to match the MaxiMet Marine.
GMX260 & 560 Compact Weather Stations ASCII Setup CRLF or CR Termination: Echo: ON or OFF Wind 0-359 degrees North Alignment: Sensor Windspeed: ON or OFF MS, KTS, MPH, KPH, FPM Wind Speed Units: (Metres/Second, Knots (Nautical Miles/Hour), Miles/Hour, Kilometres/Hour, Feet/Minute) 0.00m/s to 5.00m/s No-Direction Wind Speed:...
Page 39
GMX260 & 560 Compact Weather Stations 10 (1-10) Long Term Average: Configures WMO Long Term Average as the defined multiple of the Short Term Average i.e. if AVGSHORT is 10 and AVGLONG is also 10, Long Term Average is a rolling average of the last 100 outputs.
Page 40
When the output rate is set to once per minute or once per hour, wind averaging is disabled. The default output rate from MaxiMet Marine is one new reading every second. In this case the WMO averaged wind reading result will be based on: ...
Page 41
Status Code will read 0100 (Measurement Average Building). If MaxiMet Marine is in polled mode then when polled (default 1Hz output) MaxiMet Marine will output the last valid 10- minute wind speed and direction average, updated every minute along with last valid 1 minute gust magnitude, due to default WMO settings.
Page 42
(the station height), a correction is made to make the reading of the pressure sensor seem as if it were made at sea level. This means that the pressure reading has to be slightly increased from the value read by the MaxiMet sensor situated above sea level (often known as the station pressure).
Page 44
Outputs MaxiMet Date and Time VOLT Outputs the MaxiMet Supply Voltage STATUS. Outputs the MaxiMet Sensors Status Code (see Appendix L p83) WINDSTAT Outputs Status Codes relating to Wind Sensor Data (see Appendix L p83) USERINF User Information up to 16 characters, excludes "@", ",", "*", "%" and "?"...
Page 45
GMX260 & 560 Compact Weather Stations System 0 or 1 Power Mode: 0 is the default normal power operation mode 1 is a power-saving mode and with this set then the unit will make one reading only at the output rate whether in polled mode or continuous mode. For lowest power set the unit for 1 output reading per hour.
Page 46
This field allows the user to, for instance, record installation or calibration dates, e.g. Cal due 15.08.17 PowerUp ON or OFF Status Message Output: E.g. MAXIMET GMX560 2669 V2.00.24 Reports MaxiMet Model details and Firmware version. Report Message Output: ON or OFF E.g. NODE,DIR,SPEED,CDIR,PRESS,RH,TEMP,DEWPOINT,,TIME,VOLT,STATUS,CHECK Reports data string output parameters and output order.
Page 47
GMX260 & 560 Compact Weather Stations MODBUS Mode: RTU or ASCII 1 to 247 Address: Data Bits: 8 for Modbus RTU, 7 for Modbus ASCII 2 for No Parity, 1 for Even/Odd Parity Stop Bits: Parity: NONE, ODD, or EVEN 10, (0-255) Termination Char ASCII code: 1000 (500 to 10000)
Page 48
GMX260 & 560 Compact Weather Stations Heating The heating tab can be used to change the Heater Control Settings used by Maximet. Heater Mode This setting selects the way the heater will work. The options are • Off – this mode disables the heater until the heater setting is changed •...
Configuration for Polled Mode (MaxiMet Set for Power Mode 0) To configure a MaxiMet Marine unit for polled mode: Connect a default-set MaxiMet Marine to a PC as described in Section 5. Open MetSet as described on Appendix D. Click on the Edit Comms page:- Set Protocol for required poll mode interface e.g.
Report slave/server ID 0x11 Requires: MaxiMet MetSet Software Connect a MaxiMet to a PC COM port (default communication is RS232). Open Gill MetSet Software. Click on Connect and Read to reach the editing pages as shown below. gillinstruments.com Document Number: 1957-PS-029 Iss 3...
Page 51
Node ID: Default is Q Not used for Modbus Output Rate: Default is 1Hz Set update rate for MaxiMet Marine Data Message Mode: Default is CONT Ensure that the setting is CONT mode; Message Mode POLL is not applicable for Modbus use.
Page 52
To determine Modbus register numbers applicable to a MaxiMet parameter, start out with setting up the MaxiMet in ASCII mode and determining which parameters are to be output, and the exact order that they are to be output before setting to Modbus Comms.
Page 53
GMX260 & 560 Compact Weather Stations Summary of Modbus output parameters Output Parameter Type No. of Registers NODE 4 Bit Character String SPEED 32 Bit Floating Point Value CORRECTED SPEED 32 Bit Floating Point Value GUST SPEED 32 Bit Floating Point Value CORRECTED GUST SPEED 32 Bit Floating Point Value AVERAGE SPEED...
Page 54
• Registers start at address 40001. • Holding registers are available in the order of the MaxiMet Marine data string (which can be established by the REPORT command in non-Modbus Gill ASCII Mode). • If measurements cannot be computed (i.e. a blank field in Gill mode output string/conditions for reporting Wind Chill/ Heat Index are not being met), their Holding Register contents shall be set to the Maximum Positive value (0x7FFFFFFF for 32-bit format data (both floating point and integer), and as 0x7FFF for 16-bit format data).
Page 55
GMX260 & 560 Compact Weather Stations GMX560 Modbus Default Setting Register Table: Register Type Register Numbers Value Type 4ch string 40001-02 Node 32bit float 40003-04 Direction 32bit float 40005-06 Speed 32bit float 40007-08 Corrected Direction 32bit float 40009-10 Pressure 32bit float 40011-12 Relative Humidity 32bit float...
GMX260 & 560 Compact Weather Stations Appendix F - Configuring MaxiMet for NMEA 0183 Output Connect a default set MaxiMet Marine to a PC as described in Section 5. Open MetSet as described on Appendix D and click on the Reporting page.
Page 58
GMX260 & 560 Compact Weather Stations Immediately followed by: - GPS data if option available. $GPGGA,095010.000,5045.8065,N,00132.4003,W,1,06,1.5,-3.0,M,47.8,M,,0000*6C<CR><LF>. Where:- $GPGGA NMEA GPS Protocol Header 095010.000 UTC Time, hhmmss.sss 5045.8065 Latitude ddmm.mmmm North/South Indicator 00132.4003 Longitude ddmm.mmmm East/West indicator Position Fix Indicator (See below) Satellites being used (Range 0-12) Horizontal Dilution of Precision -3.0...
Page 59
GMX260 & 560 Compact Weather Stations Immediately followed by: $PGILT,A,+XX,D,+YY,D,+Z,TILT*HH<CR><LF> Where:- Start of sentence and proprietary sentence identifier Gill Instruments recognised NMEA manufacturer mnemonic Indicates TILT information Type of Sensor (Angular Displacement) +X-Tilt indicates unit is tipping towards east transducer "XX" degrees -X Tilt indicates unit is tipping towards west transducer "XX"...
Page 60
Where:- $WIMWV Wind Instrument Mean Wind direction and Velocity. Wind Direction. Relative Wind measurement, wind speed and/or direction information, reported with respect to the MaxiMet North marker. 000.03 Wind Speed. Knots Acceptable measurement (V is a void fail measurement). Hex Checksum* Immediately followed by:- $WIMWV,049,T,,N,A*18<CR><LF>.
Page 61
GMX260 & 560 Compact Weather Stations Immediately followed by:- $WIHDM,+261.6,M,*38 HDM sentence transmitted when heading is magnetic. $WIHDT HDT sentence transmitted when heading is true. A true heading is used when a declination has been entered. Immediately followed by:- $WIXDR,A,+02.9,D,PITCH,A,+00.7,D,ROLL*07 Where: - $WIXDR Wind Instrument Transducer Angle...
Page 62
GMX260 & 560 Compact Weather Stations Followed by GPS data if option available. $GPGGA,161229.487,3723.2475,N,12158.3416,W,1,07,1.0,9.0,M, , , ,0000*18<CR><LF>. Where $GPGGA NMEA GPS Protocol Header 161229.487 UTC Time, hhmmss.sss 3723.2475 Latitude ddmm.mmmm North/South Indicator 12158.3416 Longitude ddmm.mmmm East/West indicator Position Fix Indicator (See below) Satellites being used (Range 0-12) Horizontal Dilution of Precision Mean Sea Level (NSL) Altitude in Metres...
Page 63
GMX260 & 560 Compact Weather Stations Example GMX560 NMEA Data String. $WIMWV,311,R,000.16,M,A*0A $WIMWV,254,T,000.16,M,A*0C $WIHDM,+303.3,M,*38 $WIXDR,A,-55.1,D,PITCH,A,+76.3,D,ROLL*0E $WIXDR,C,+020.3,C,TEMP,P,1018.9,H,PRESS,H,049,P,RH*27 $GPGGA,095011.000,5045.7890,N,00132.4102,W,1,08,1.1,16.4,M,47.8,M,,0000*77 $PGILT,A,+34,D,+54,D,+1,TILT*32 Repeated every second (1Hz output). *Checksum, the 2 digit Hex Checksum sum figure is calculated from the Exclusive OR of the bytes between (and not including) the $ and * characters.
Shut down the MaxiMet unit. Change the hardware connections for SDI-12 (see section 5). Power up the MaxiMet unit (SDI-12 supply voltage 9.6V to 16V DC). Allow 10 seconds for the unit to start up before sending an SDI-12 command.
Page 65
GMX260 & 560 Compact Weather Stations SDI-12 Commands For each of the available aMx! commands and the aC! command there exists an equivalent aMCx! and aCC! command that provides a 3 character CRC on the associated send data command (aD0!, aD1! ...) immediately before the <CR><LF>...
Measurement command to retrieve a Direction and Corrected Speed) option unit only), reading of the maximum time the Status MaxiMet will take to complete a measurement, have data ready and the number of data values. aD0! Retrieve a line of the <address><relative wind...
Page 67
GMX260 & 560 Compact Weather Stations aM3! Address, Precipitation atttn<CR><LF> 00033<CR><LF> Intensity, Total Precipitation, Status aD0! Retrieve a line of the <address><precipitation 0+999.999+0999.999+0002<CR><LF> above data. intensity><total precipitation><status><CR><LF> aM4! Address, Solar atttn<CR><LF> 00026<CR><LF> Radiation, Sunshine Hours, X Tilt, Y Tilt, Z Orientation, Status aD0! Retrieve a line of the...
Page 68
GMX260 & 560 Compact Weather Stations aD0! Retrieve part of the <address><sunrise time><solar noon 0+0515+1152+1829+115+27+1908 above data. time><sunset time><position of the +1950<CR><LF> sun (azimuth)><position of the sun (elevation)><twilight (civil)><twilight (nautical)><CR><LF> aD1! Retrieve final part of <address><twilight 0+2034+0000<CR><LF> the above data (astronomical)><status>...
Page 69
GMX260 & 560 Compact Weather Stations Concurrent atttnn<CR><LF> 000350<CR><LF> measurements grouped into primary measurements, time/location, average/gust, and derived. aD0! Retrieve a line of the <address><relative 0+286+000.03+296+000.08+022.2+05 above data. (primary direction><relative wind 5+1001.4+000.000+0002<CR><LF> measurements) speed><corrected direction><corrected wind speed><temp><relative humidity><pressure><precipitation intensity><solar radiation><CR><LF> aD1! Retrieve a line of the <address><x-tilt><y-...
Page 70
GMX260 & 560 Compact Weather Stations elevation><twilight civil><twilight nautical><twilight astronomical><status><CR><LF> aXU1! set measurement aUM/S<CR><LF> 0UM/S<CR><LF> units for aM8! to m/s aXU2! set measurement aUKPH<CR><LF> 0UKPH<CR><LF> units for aM8! to kph aXU3! set measurement aUMPH<CR><LF> 0UMPH<CR><LF> units for aM8! to mph aXU4! set measurement aUKTS<CR><LF>...
Open Gill MetSet Software (see Appendix D) Click on Connect and Read. MetSet will scan COM port settings for a connected MaxiMet Marine but as the COMMS protocol is not matched will be unable initially to find the MaxiMet Marine.
Page 72
GMX260 & 560 Compact Weather Stations Ensure the MaxiMet Marine is wired for RS232 operation and power and click on Next. Enter the MaxiMet COM Port connection number. Using dongle check box is only applicable when using a MetConnect device.
Page 73
GMX260 & 560 Compact Weather Stations Ensure power is now disconnected from the MaxiMet Marine. If using the Gill Instruments RS232 to USB configuration cable then unplug the 8-way connector from the base of the MaxiMet Marine. Now click on Next.
Page 76
Hold down the * (asterisk) key on the keypad. With the * key still held down, apply power to the MaxiMet Marine If using the Gill Instruments RS232 to USB configuration cable then plug in the 8-way connector to the base of the MaxiMet Marine.
For those MaxiMet units that have a Tilt function output it is possible to use a Check Tilt command that results in just X, Y, Z Tilt information (and compass output with wind output models) being output at 4Hz with additional decimal point accuracy, should this be required for installation set-up.
Appendix J - Using a Terminal Program to set MaxiMet Date and Time As an alternative to using MetSet to set MaxiMet Marine time which might add a delay to time setting as MetSet saves settings (up to 60 seconds) then MaxiMet Marine TIME can be set manually with potentially more accuracy against a...
MetView software allows you to view the MaxiMet data visually and has a simple data logging facility. Before you can use MetView, check that MaxiMet is correctly connected to a serial COM port or USB COM port on your PC.
Connection is ‘Receive-Only’ Use (tick) if the MaxiMet Marine connection to the PC has only transmit wires connected and a MetSet version of its current device settings is available to upload to MetView. Select ‘Connection is ‘Receive-Only’’ tick box and click on the Scan button.
Page 83
Select Connect to go to the data view screen. To select the other MaxiMet Marine then in the data view screen select the Disconnect button and use the drop-down menu below to select and connect to the new MaxiMet Marine.
GMX260 & 560 Compact Weather Stations The MetView Console When connected correctly, MetView displays its data-monitoring console. This consists of gauges for all of MaxiMet Marine enabled parameters. Buttons beneath each of the gauges allow you to choose the displayed units and other options. Each gauge also shows the maximum and minimum values recorded during the current session.
Page 85
No gauges are associated with the above digital readouts. The order in which the instruments are shown in the MetView display reflects the order in which the instrument data appears in the MaxiMet Marine data string. gillinstruments.com Document Number: 1957-PS-029 Iss 3...
Page 86
MetView Scale and Units of Measure Options MetView Console buttons can convert data from the MaxiMet Marine to read different units of measure or scale settings, or in the case of Wind readings the type of display (e.g. Maritime, NSEW).
Page 87
MetView thermometer style gauge ranges may be altered to view changes in sensor readings more visibly. These changes only affect MetView settings and do not affect the MaxiMet Marine output or logged data. For instance, if the typical Temperature measurement range required is from 0 to +30 °C then the temperature gauge range can be adjusted to reflect this.
Page 88
Data is only shown up to the time when the graph function is selected; the graph is not updated once opened. Data is collected from the time that MetView is opened and reading data from a MaxiMet Marine. Double click on the...
GMX260 & 560 Compact Weather Stations Data Logging MetView logs data based on the MaxiMet Marine configuration not on the MetView console settings.To start, click on the Log disabled button on the open MetView console. The Logging dialog box is displayed.
Page 90
Click on the OK button. If logging has stopped, the Logging button shows a red-background cross instead of the green-background tick (see above). An example of the logged MaxiMet data .log file opened by Notepad is shown below: gillinstruments.com Document Number: 1957-PS-029 Iss 3...
Select Serial. Select MaxiMet connected COM port. Click on OK. Tera Term opens at 9600 baud by default but MaxiMet Marine uses 19200 as a default, so change Tera Term baud rate setting to 19200. gillinstruments.com Document Number: 1957-PS-029 Iss 3...
Page 94
GMX260 & 560 Compact Weather Stations The following dialog box will open on the PC desktop. To stop logging, click on the Close button. Understanding Logged Data Logged data is stored to a file with a .log extension. This can be viewed in any text/HTML editor or spreadsheet application.
The barometer device is located internally and is not maintainable or replaceable by a user. Consideration should be given to checking the Pressure readings against a standard every 12 months. If required, return the MaxiMet to Gill Instruments to check the barometer calibration (see page 86) for details about returning the unit).
24 months to ensure proper performance (see page 84) for details about returning the unit). Calibration A calibration check can be done by any user/distributor by comparing the values measured by MaxiMet Marine with a reference value or in an environmental chamber. Users should understand that these checks are not the same as the calibration checks or calibration done at Gill but they can provide users with some degree of confidence to the validity of their measurements.
Page 97
GMX260 & 560 Compact Weather Stations Sensor Status Codes Code Status Condition 0000 No fault conditions detected in measurement period. 0001 Wind measurement faul.t Wind Sensor faulty. 0002 GPS error. E.g. Locating Satellite fix. Source for Corrected Wind Direction 0004 GPS notification.
Safe Mode If a unit is received that will not communicate or the configuration settings are not known, then Safe Mode can be used to establish communication with the MaxiMet Marine and change configuration settings (see Appendix H). Bench Test See para-3.11...
Software Not in order of output, see Appendix C for applicability and Appendix D for MetSet set up. NODE - Node Letter MaxiMet identifying Node letter at beginning of the data string. Result e.g. Q (default). SPEED -Wind Speed Wind Speed measurement.
Page 100
GMX260 & 560 Compact Weather Stations GSPEED (WMO) - Gust Speed Outputs WMO Gust Speed. Maximum Gust Magnitude shall be computed over a block of m gust magnitudes as follows: ___ = max {_ , _ … _ Where: = _ℎ_ _...
Page 101
(see page 37). Result e.g. 001.45 (metres/second default). DIR - Direction Wind Direction relative to the MaxiMet north marker. Result e.g. 132 (degrees). CDIR - Corrected Direction Corrected Wind Direction shall be computed as the Apparent Wind Direction (i.e.: using Compass Heading) when Compass Heading is available but any one (or more) of GPS Speed and GPS Heading are unavailable.
Page 102
Outputs WMO average Compass Corrected Direction wind reading based on AVG short and AVG long settings (see page 62). Result e.g. 131 (degrees). PRESS - Pressure Outputs the MaxiMet Pressure reading. Result e.g. 1021.3 (hectopascals default). gillinstruments.com Document Number: 1957-PS-029 Iss 3...
Page 103
GMX260 & 560 Compact Weather Stations PASL Pressure at Sea Level Outputs Barometric Pressure at Sea Level if HASL figure set (see page 64). = ( 0 × + × ( −ℎ ) × Where: = adjusted pressure = pressure (pascals) - as measured by the pressure sensor...
Page 105
GMX260 & 560 Compact Weather Stations DEWPOINT - Dewpoint Outputs calculated Dewpoint from Temperature and Humidity readings. = − 1 Where: = Dewpoint temperature = Triple point temperature (in K) = ⁄ . ...
Page 106
HI s = Simple Heat Index expressed as an apparent temperature in degrees F When HI s < (HI r + R Adj), MaxiMet Heat Index shall be: HI = HI r + R Adj where: HI = MaxiMet Heat Index expressed as an apparent temperature in degrees F, HI r = Rothfusz Heat Index expressed as an apparent temperature in degrees F, R Adj = Rothfusz Adjustment.
Page 107
GMX260 & 560 Compact Weather Stations Heat Index is only reported when the temperature is above 75°F (approximately 23.88°C) and both Relative Humidity and Temperature are functioning. AIRDENS - Air Density Outputs calculated Air Density from Pressure and Temperature readings. ...
Page 108
GMX260 & 560 Compact Weather Stations TWIC - Twilight Civil Begins in the morning, or ends in the evening, when the geometric centre of the Sun is 6 degrees below the horizon. Beginning of Morning Twilight (Civil): Defined as the instant in the morning, when the centre of the Sun is at a depression angle of six degrees (6°) below an ideal horizon.
Page 109
XTILT - X Tilt X-Tilt shall be displayed in degrees with 2 signed integral digits over the range ±89 degrees. With respect to the MaxiMet north marker: +XX shall indicate that the unit is tipping towards east. -XX shall indicate that the unit is tipping towards west.
Page 111
GPS Heading shall be displayed with 3 integral digits. Result e.g. 064 (degrees). GPSSPEED - GPS Speed over Ground Velocity at which the MaxiMet unit with GPS is travelling over ground. Result e.g. +000.10 (metres/second (default)). In feet/minute setting then a reading might be 00020 (no decimal places).
Page 112
GMX260 & 560 Compact Weather Stations TIME (and Date) - MaxiMet Date and Time (can be updated by GPS Option) Time can be set manually by the user or updated by the GPS Module (if fitted). GPS time can be automatically updated every hour (GPS default setting).
GMX260 & 560 Compact Weather Stations Glossary & Abbreviations Item Meaning Calibration Carriage Return CRLF Carriage Return Line Feed Comma Separated Variable Engineering ESCape key on keyboard. End of string character Feet per minute GrouND HEXadecimal InPut IP66 Protection Classification Kilometres per Hour Line Feed Metres per Second...
Appendix N - M12 to USB Configuration Cable installation The M12 to USB Configuration Cable can be used to connect a MaxiMet Marine to a PC running MetSet software. This will allow the MaxiMet Marine to be configured and tested prior to installation. Please note that this cable should only be used to configure and test the MaxiMet Marine and should not be used in normal operation.