Binatone DVS-2001 Manual
Binatone DVS-2001 Manual

Binatone DVS-2001 Manual

Digital voltage stabilizer

Advertisement

Quick Links

ENGLISH
DIGITAL VOLTAGE STABILIZER
To get the best results from your Binatone product
please read these instructions carefully.
DVS-1001, DVS-1601, DVS-2001, DVS-3001, DVS-5001

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DVS-2001 and is the answer not in the manual?

Questions and answers

Summary of Contents for Binatone DVS-2001

  • Page 1 ENGLISH DIGITAL VOLTAGE STABILIZER To get the best results from your Binatone product please read these instructions carefully. DVS-1001, DVS-1601, DVS-2001, DVS-3001, DVS-5001...
  • Page 2 & value products available in the market today. Our commitment lies solely in delivering high quality, affordable products. Our international team is constantly pursuing every effort to make products not just ‘appliances’ but ‘lifestyle improvements’. Check out all the latest Binatone products at: www.binatonelifestyle.com...
  • Page 3: Important Safeguards

    IMPORTANT SAFEGUARDS When using electrical appliances – especially when children are present, basic safety precautions should always be followed to reduce the risk of fire, electric shock and/or injury to persons. ✓ READ ALL INSTRUCTIONS ✓ Make sure your power supply is consistent with the rated specification of the product before connecting.
  • Page 4: Know Your Appliance

    KNOW YOUR APPLIANCE Model Specification Front Panel Rear Panel Input: 110-280V~ 50Hz Output: 1001 110 & 230V~ 50Hz +/-10% Capacity: 1000W (1000VA MAX) Input: 110-280V~ 50Hz Output: 1601 110 & 230V~ 50Hz +/-10% Capacity: 1600W (1600VA MAX) Input: 110-280V~ 50Hz Output: 2001 110 &...
  • Page 5: Control Panel

    BEFORE FIRST USE Carefully remove all packaging and ensure the product is not damaged in any way. If you notice any damage – contact your authorized dealer or Binatone Customer Care (see Service & Customer Care) Follow the setup & operating instructions below.
  • Page 6: Setup Instructions

    3. Ensure there is at least 10cm gap between the DVS & any nearby articles. 4. Do not place anything on top of the DVS or allow anything to block the rear of the unit. 5. (DVS-1001, DVS-1601 & DVS-2001) Plug the DVS input power cord into a grounded (earthed) power outlet socket (DVS-3001 &...
  • Page 7: Outlet Connections

    On the rear panel of the DVS – socket outlets are provided – that can be used to plug in load appliances. Below are details of the socket outlets available on each model and the maximum loads possible. DVS-1001 MAX load is 1000W from all sockets (when input 230V~) OUTLET...
  • Page 8 OUTLET CONNECTIONS continued DVS-2001 MAX load is 2000W from all sockets (when input 230V~) OUTLET CONNECTION SOCKET TYPE VOLTAGE & WATTAGE A (upper) 2 pin socket 230V~ 50Hz 8.69A 2000W(*) A (lower) Universal 3 pin socket 2 pin socket 110V~ 50Hz 6.36A 700W(*) USB Type A 5V DC 2.0A (2000mA) (*) CAUTION: If more than one appliance is plugged into sockets A &...
  • Page 9 OUTLET CONNECTIONS continued DVS-5001 MAX load is 5000W from all sockets (when input 230V~) OUTLET CONNECTION SOCKET TYPE VOLTAGE & WATTAGE A (upper) 2 pin socket 230V~ 50Hz 13A 3000W(*) A (lower) Universal 3 pin socket 110V~ 50Hz 10A 1100W(*) 2 pin socket Type M - 3 pin socket 230V~ 50Hz 16A 3680W(*)
  • Page 10 NOTE: When connecting the load appliance - ensure the total load (wattage) of the connected appliance(s) does not exceed the rated maximum for the DVS. 2. Switch on the DVS unit – using the power switch (DVS-1001/DVS-1601/DVS-2001) or circuit breaker (DVS-3001/DVS-5001) - located on the rear panel.
  • Page 11 DVS SAFETY PROTECTION SYSTEMS The Binatone range of DVS units come equipped with an Integrated Automatic Protection Circuit (IAPC) that monitors the appliance and provides these safety systems: OUTPUT OVER VOLTAGE PROTECTION This system protects connected load appliances whenever the output voltage is higher than the normal range by cutting off the power &...
  • Page 12 DELAY OPERATION continued Short Delay - Mode 1 (button out) When the input power is restored - this provides a 6 second delay before the output power is energised. This is the default mode and can be used for all appliances not stated below. Long Delay - Mode 2 (button in) When the input power is restored - this provides a 180 second (3 minutes) delay before the output power is energised.
  • Page 13: Care And Cleaning

    DVS OPERATION TIPS Avoid overloading: • Do not use the DVS beyond its maximum output power. • When connected to any appliance with built in motor, pump or compressor – the starting power is generally several times that of the appliance’s listed power rating. •...
  • Page 14: Service & Customer Care

    SERVICE & CUSTOMER CARE There are no user serviceable parts inside this appliance. If the power cord or plug are damaged it must, for safety reasons, be replaced by Binatone or an authorised Binatone repairer. If you need help with: •...
  • Page 15: Warranty

    This is a domestic product – warranty does not cover products that have been used for commercial purposes. BINATONE at its option, will repair or replace a product found to be defective during the warranty period. Should this product become defective by reason of improper workmanship or material defect during the specified warranty period, BINATONE will repair or replace the same effecting all necessary part replacements.
  • Page 16 Please consider recycling this instruction manual responsibly Binatone Lifestyle Appliances • LONDON • HONG KONG • DUBAI • LAGOS • ACCRA • Rev 2 (210525)

Table of Contents