SUMMARY For users ………………………………………………………………………………. P.3-P.10 1. GENERAL INFORMATION 1.1. Contents: 1.2. Operating conditions and range: 1.3. Advantages of different modes: 1.4. Kind reminder: 2. OPERATIONS 2.1. Notice before using 2.2. Operation instructions 2.3. Daily maintenance and winterizing 3. TECHNICAL SPECIFICATION For installers and professionals ………………………………………………...
Page 3
Warning: a. Please read the following tips before installation, use and maintenance. b. Installation, removal and maintenance must be carried out by Professional in accordance with the instructions. c. Gas leakage test must be done before and after installation. 1. Use a.
Page 4
d. Installation must be stopped if any gas leakage, and the unit must be returned to professional maintenance center. 3. Transportation and Storage a. Sealing is not allowed during transportation b. Transporting goods at a constant speed is needed to avoid sudden acceleration or sudden braking, so as to reduce the collision of goods.
FOR USERS 1. GENERAL INFORMATION 1.1. Contents After unpacking, please check if you have all the following components. Anti-vibration rubber feet are included in accessory box as below: NOTICE: Please do not install wrong direction of the water union. STEP 1 STEP 3 STEP 2...
FOR USERS 1.2. Operating conditions and range ITEMS RANGE ~43 °C °C Operating range Air temp °C ~40 °C heating Temp. setting The heat pump will have ideal performance in the operation range Air 15°C~25°C. 1.3. Advantages of different modes The heat pump has three modes: Turbo, Smart and Silence.
Page 7
FOR USERS 1.4.3. Don’t put obstacles before the air inlet and outlet of the heat pump. 1.4.4. Don’t put anything into inlet or outlet, or the efficiency of the heat pump will be reduced or even stopped. 1.4.5. Don’t use or store combustible gas or liquid such as thinners, paint and fuel to avoid fire. 1.4.6.
FOR USERS 1.4.8. Please cut off the power in the lightning storm weather. 1.4.9. Please note that following codes are not failure. CODES No water flow Anti-Freezing Reminder Out of the operating range Insufficient water flow or pump blocked Power abnormal 2.
Page 9
FOR USERS SYMBOL DESIGNATION FUNCTION Power On/Off ON/OFF Wifi setting Unlock Press it for 3 seconds to unlock/lock screen Speed Select Turbo/Smart/Silence mode Up / Down Adjust set temperature Note: (Button will be light all the time when power is on.): ①...
Page 10
FOR USERS Heating Heating capacity percentage Real-time power consumption display Wifi connection Water inlet Water outlet 1. Power On: Press for 3 seconds to light up screen, then press to power on heat pump. 2. Adjust Set Temperature: When screen is unlocked, press to display or adjust the set temperature.
FOR USERS 7. Wifi setting Please kindly check the last page. 2.3. Daily maintenance and winterizing 2.3.1. Daily Maintenance Please don’t forget to cut off power supply of the heat pump Please clean the evaporator with household detergents or clean water, NEVER use gasoline, thinners or any similar fuel.
FOR INSTALLERS AND PROFESSIONALS 1. TRANSPORTATION 1.1. When storing or moving the heat pump, the heat pump should be at the upright position. 1.2. When moving the heat pump, do not lift the water union since the titanium heat exchanger inside the heat pump will be damaged.
FOR INSTALLERS AND PROFESSIONALS 2.2. Installation instruction 2.2.1. Location and size To avoid air recirculation, the heat pump should be installed in a place with good ventilation or should reserve sufficient space for installation and maintenance. Please refer to the schema below:...
Page 15
FOR INSTALLERS AND PROFESSIONALS UNIT=MM IXR26 IXR36 IXR46 IXR56 IXR66 1125 IXR80 1074 IXR80T 1074 IXR110T 1264 ※ Above data is subject to modification without notice. 2.2.2. Heat pump installation. The frame must be fixed by bolts (M10) to concrete foundation or brackets. The concrete foundation must be solid;...
Page 16
FOR INSTALLERS AND PROFESSIONALS 1. Connecting your power wire Please use cross screwdriver to take off the 2 screws at the bottom of the right side panel. Take off the lower half of the panel. Unscrew the 4 screws on the cover of the electrical box.
FOR INSTALLERS AND PROFESSIONALS NOTE: Must be hard wired, no plug allowed. For your safe use in winter, it’s strongly recommended to equip heating priority function. For the detailed wiring diagram, please refer to Appendix 1. 3. Options for protecting devices and cable specification MODEL IXR26 IXR36 IXR46 IXR56 IXR66 IXR80 IXR80T IXR110T Rated Current (A)
FOR INSTALLERS AND PROFESSIONALS 2.4. Maintenance and winterizing 2.4.1. Maintenance The maintenance should be carried out once per year by qualified professional technician. Cut off power supply of the heat pump before cleaning, examination and repairing . Do not touch the electronic components until the LED indication lights on PCB turn off.
FOR INSTALLERS AND PROFESSIONALS 4. FAILURE CODE DISPLAY NOT FAILUREDESCRIPTION No water protection Power supply excesses operation range Excessive temp difference between inlet and outlet water(Insufficient water flow protection) Ambient temperature too high or too low protection Anti-freezing reminder DISPLAY FAILUREDESCRIPTION High pressure protection Low pressure protection...
FOR INSTALLERS AND PROFESSIONALS APPENDIX 3: HEATING PRIORITY WIRING DIAGRAM (OPTIONAL)
Page 23
FOR INSTALLERS AND PROFESSIONALS Parallel connection with filtration clock A: Water pump timer B: Water pump wiring of Heat Pump Note: The installer should connect A parallel with B (as above picture). To start the water pump, condition A or B is connected. To stop the water pump, both A and B should be disconnected.
FOR INSTALLERS AND PROFESSIONALS 5. WI-FI SETTING 5.1. APP Download Android mobile please download from iPhone please download from 5.2. Account registration a) Registration by Cell phone number/Email...
Page 25
FOR INSTALLERS AND PROFESSIONALS b) Cell phone number registration 5.3. Create family Please set a name for family and choose the room of device.
Page 26
FOR INSTALLERS AND PROFESSIONALS 5.4. Three methods of device binding Please connect your phone to the Wi-Fi network first. 5.4.1. Auto Discovery (Bluetooth) a) Please make sure the Bluetooth function is enabled on your phone. b) Press for 3 seconds after screen unlock, will be flashing rapidly to enter Wi-Fi binding status.
Page 27
FOR INSTALLERS AND PROFESSIONALS 5.4.2. EZ Mode (Easy-connect) a) Activate Wi-Fi module Press for 3 seconds after screen unlock, will be flashing rapidly to enter Wi-Fi binding status. b) Click "Add device", follow instructions below to finish binding. display on the screen once Wi-Fi connection success.
Page 28
FOR INSTALLERS AND PROFESSIONALS 5.4.3. AP Mode Activate Wi-Fi module a) Press for 10 seconds after screen unlock, will be flashing slowly to enter Wi-Fi binding status. b) Click "Add device", follow instructions below to finish binding. display on the screen once Wi-Fi connection success.
Page 29
FOR INSTALLERS AND PROFESSIONALS 5.5. Operation instructions The following instructions are for heat pumps with heating function only. More share device Heating capacity percentage Indicate the status of Heating Real-time power consumption Switching °C/°F The current swimming pool water temp Setting temp Temp adjustment slider Cloud Timer...
Page 30
FOR INSTALLERS AND PROFESSIONALS 5.6. Share devices to your family members After binding, if your family members also want to control the device. Please let your family members register the APP first, and then the administrator can operate as below (The following pictures are for reference only): Then your family members will see this heat pump once they log in to the APP.
Page 32
Thank you for choosing Fairland TurboSilence Inverter. The factory reserves the final interpretation right. And keep the right to stop or change product specification and design without prior notice at any time, no need to bear the resulting obligations. Version: Fc2Xr32-1...
Need help?
Do you have a question about the TurboSilence IXR80 and is the answer not in the manual?