2.2. Warranty MODULE OVERVIEW – PHONO INPUT MODULES 3.1. IN 1: MM RCA input module 3.1.1. IN 1 input module, rear panel 3.1.2. Top view, IN 1 input module 3.1.3. IN 1 technical data 3.1.4. IN 1 diagrams 3.2. IN 2: MC RCA input module 3.2.1.
Page 3
CONTENTS 3.5. IN 7: MC XLR with step-up transformer 3.5.1. IN 7 input module, rear panel 3.5.2. Top view, IN 7 input module 3.5.3. IN 7 technical data 3.5.4. IN 7 description 3.5.5. IN 7 diagrams MODULE OVERVIEW – LINE INPUT MODULES 4.1.
Page 4
CONTENTS 5.2. OUT 2 output module: RCA direct drive 5.2.1. OUT 2 output module, rear panel 5.2.2. Top view, OUT 2 output module 5.2.3. OUT 1 technical data 5.2.4. Regulated output of the OUT 2 module (variable) 5.2.5. Unregulated output (fixed) 5.2.6.
FOREWORD FOREWORD Dear Music Enthusiast, You have chosen a modular OCTAVE model that you can customize with different op- tional slide-in modules. Thank you for choosing this flexible solution from our product range and for your trust. A variety of different input modules are available for your amplifier, both for the phono stage and additional line-level inputs.
Service and maintenance For reasons of safety, please ensure that servicing, repairs and other modifications to OCTAVE equipment are carried out only by a qualified technician. Defective fuses should also only be replaced by a qualified technician. Always replace fuses with ones of the same type and rating.
MODULE OVERVIEW – PHONO INPUT MODULES Warranty OCTAVE can only guarantee the safety, reliability and performance of this unit if modifi- cations and repairs are carried out by specialized personnel and if the amplifier is oper- ated in accordance with the instructions contained in this manual.
MODULE OVERVIEW – PHONO INPUT MODULES 3.1.2. Top view, IN 1 input module Legend Rear panel Input impedance Low = 1 kohm The “Low” setting is designed for special MC high-output systems with an MM output level. High = The “High” setting is for classic MM 47 kohms pickup cartridge systems.
MODULE OVERVIEW – PHONO INPUT MODULES 3.1.4. IN 1 diagrams MM input noise level Measurement on the fixed output Total harmonic distortion THD in the range 400 Hz – 20 kHz Measurement on the fixed output, output voltage 1 V...
MODULE OVERVIEW – PHONO INPUT MODULES 3.2.2. Top view, IN 2 input module Legend Rear panel Resistance selector switch for right and left channel Gain switch Gain (amplification) switching enables the MC input to be adjusted to low and high-output systems. Please re- fer to the owner’s manual for the pickup cartridge sys- tem provided by the manufacturer for the specific data for your pickup cartridge system.
MODULE OVERVIEW – PHONO INPUT MODULES 1. Please see the technical data or the pickup cartridge system’s owner’s manual for the recommended impedance. 2. Set the recommended input impedance according to the following table. If the rec- ommended input impedance is not listed in the table, use the closest value. If two values are possible, you can select the optimal impedance using a listening test.
MODULE OVERVIEW – PHONO INPUT MODULES 3.2.4. IN 2 diagrams MC RCA input noise level Measurement on the fixed output Total harmonic distortion THD in the range 400 Hz – 20 kHz Measurement on the fixed output, output voltage 1 V...
MODULE OVERVIEW – PHONO INPUT MODULES 3.3.2. Top view, IN 3 input module Legend Rear panel Resistance selec- (See “Setting the input impedance for MC pickup car- tor switch for right tridge systems” on page 7) and left channel Gain switch Gain (amplification) switching enables the MC input to be adjusted to low and high-output systems.
MODULE OVERVIEW – PHONO INPUT MODULES 3.3.3. IN 3 technical data MC XLR technical data Input sensitivity 0.1 – 1 mV Input impedance 62 ohms – 1 kohm/4.7 nF Gain factor 65 dB Gain high, 58 dB Gain low 72 dB Gain high, -78 dB Gain low ...
Page 17
MODULE OVERVIEW – PHONO INPUT MODULES Total harmonic distortion THD in the range 400 Hz – 20 kHz Measurement on the fixed output, output voltage 2 V...
MODULE OVERVIEW – PHONO INPUT MODULES 3.4.2. Top view, IN 6 input module Legend Rear panel Magnetically shielded transformer Pin header for the The input modules have one pin fewer than the output pin connector in modules and can therefore only be mounted in input the main unit slots.
MODULE OVERVIEW – PHONO INPUT MODULES 3.5.2. Top view, IN 7 input module Legend Rear panel Magnetically shielded transformer Pin header for the The input modules have one pin fewer than the output pin connector in modules and can therefore only be mounted in input the main unit slots.
MODULE OVERVIEW – PHONO INPUT MODULES 3.5.5. IN 7 diagrams Frequency response with a cartridge DC resistance of 5 ohms Due to the lossless core of the transformer the input impedance is high and constant. This results in the flat frequency response of 20 Hz – 75 kHz (-1/-3 dB) even with a car- tridge resistance up to 5 ohms.
MODULE OVERVIEW – LINE INPUT MODULES MODULE OVERVIEW – LINE INPUT MODULES IN 4: Line-in XLR/RCA, switchable 4.1.1. IN 4 input module, rear panel Legend Mounting 4 x size M3 x 8 cross slot, Phillips No. 1 screwdriver screws RCA inputs L (white): left input, R (red): right input XLR inputs R: right input, L: left input...
MODULE OVERVIEW – LINE INPUT MODULES 4.1.2. Top view, IN 4 input module Legend Rear panel Pin header for the pin con- nector in the main unit Push button switch Ribbon cable connector (For assembly, see page 22).
MODULE OVERVIEW – LINE INPUT MODULES 4.1.3. Installing the IN 4/IN 8 input module Connecting the ribbon cable connector ► Please disconnect the unit from the mains before opening the cover ► Push in the ribbon cable connector until the locking pin clicks into the locking lever. Legend Ribbon cable Ribbon cable connector...
MODULE OVERVIEW – LINE INPUT MODULES Legend Ribbon cable connector tab 4.1.4. IN 4 technical data Line-in technical data, switchable Input sensitivity 100 mV – 7 V RCA/XLR input impedance 50 kohms/25 kohms RCA/XLR gain factor 0 dB/+6 dB Crosstalk attenuation L – R >-80 dB Signal-to-noise ratio -120 dB ...
MODULE OVERVIEW – LINE INPUT MODULES 4.2.2. Top view, IN 8 input module Legend Rear panel Ground lift Slide switch position toward rear panel: Ground connected Slide switch position toward pin header: Ground disconnected The ground lift allows you to isolate the ground con- nection of the balanced input and signal ground of the main unit.
MODULE OVERVIEW – LINE INPUT MODULES 4.2.4. IN 8 technical data Line-in XLR technical data, with transformer Input sensitivity 100 mV – 6 V Input impedance 10 kohms/ 30 Hz – 40 kHz Gain factor 0 dB /1:1 transformer Signal-to-noise ratio -115 dB Frequency range 30 Hz –...
MODULE OVERVIEW – LINE INPUT MODULES 4.3.2. Top view, IN 9 input module Legend Rear panel Ground Lift Slide switch position toward rear panel: Ground connected Slide switch position toward pin header: Ground disconnected The ground lift allows you to isolate the ground con- nection of the balanced input and signal ground of the main unit.
MODULE OVERVIEW – OUTPUT MODULES MODULE OVERVIEW – OUTPUT MODULES Note Outputs on OCTAVE preamplifiers are generally installed permanently. By contrast, the OCTAVE Phono Module features modular outputs. Therefore, different output modules can also be used in the Phono Mod- ule.
MODULE OVERVIEW – OUTPUT MODULES 5.1.2. Top view, OUT 1 output module Legend Rear panel Pin header for the pin connector in the main unit 5.1.3. OUT 1 technical data Standard RCA technical data Fixed output voltage Variable output voltage 0 –...
MODULE OVERVIEW – OUTPUT MODULES 5.1.5. Unregulated output (fixed) The unregulated output supplies an output signal at line level 0.7 V at approximately the same magnitude as a modern CD player. This output is intended for connection to line-level inputs on a preamplifier/integrated amplifier.
MODULE OVERVIEW – OUTPUT MODULES 5.2.2. Top view, OUT 2 output module Legend Rear panel 6N6 tube Amplifier tube only for regulated output. Also available under designations 6N23, ECC88, and 6922. Gain switch Gain switch for switching the gain of the regulated output. Position 1: The level in position 1 is identical to the Gain = 0 dB...
MODULE OVERVIEW – OUTPUT MODULES 5.2.4. Regulated output of the OUT 2 module (variable) The regulated output is controlled by a separate line stage on the OUT 2 module. The variable output is intended for direct control of unbalanced power amplifiers and active loudspeakers.
Page 38
MODULE OVERVIEW – OUTPUT MODULES Total harmonic distortion THD Gain high and Gain low in the range 10 Hz - 20 kHz Measurement on regulated output, output voltage 2 V Both graphs show an extremely low level of distortion.
MODULE OVERVIEW – OUTPUT MODULES 5.3.2. Top view, OUT 3 output module Legend Rear panel 6N1 tubes Amplifier tubes only for regulated output. Also available under designations 6N23, ECC88, and 6922. Function switch Switch to switch between the XLR output “variable”/“fix” functions.
MODULE OVERVIEW – OUTPUT MODULES 5.3.4. Regulated XLR output of the OUT 3 module (variable) The regulated output is controlled by a separate line stage on the OUT 3 module. The regulated XLR output is intended for direct control of balanced power amplifiers, active loudspeakers, preamplifiers, and integrated amplifiers.
Page 42
We reserve the right to alter and improve the specifications in pur- suit of better. OCTAVE is a regis- tered trademark of Andreas Hof- mann Octave Audio. This manual is the copyright of Andreas Hofmann. Reproduction in whole or part is prohibited.
Need help?
Do you have a question about the IN 2 and is the answer not in the manual?
Questions and answers