Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
innomar Manuals
Measuring Instruments
SES medium-100
User manual
innomar SES medium-100 User Manual
Narrow-beam parametric sub-bottom profilers
Hide thumbs
1
2
3
4
5
6
Table Of Contents
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
page
of
197
Go
/
197
Contents
Table of Contents
Troubleshooting
Bookmarks
Table of Contents
Table of Contents
1 Important Hints - Attention Please
Safety Rules
Innomar SBP User Manual
What Is Shipped
2 Hardware / System Installation
System Overview
Transducer Handling and Installation
General
Transducer Handling
Pole-Mount Transducer Installation
Hull-Mount Transducer Installation / Mounting Frame
Topside Unit Installation
Innomar SBP Front Panel: Connectors and Switches
Innomar SBP Rear Panel
Ethernet and Wifi Setup ("Smart" / "Compact")
3 Ethernet and Wifi Setup (“Smart” / “Compact”)
4 SES for Windows (SESWIN System Software)
Installing / Updating the Innomar SESWIN Software
Starting the Innomar SESWIN Software
Innomar "Smart" and "Compact" Models
Innomar "Light", "Standard" and "Medium-100" Models
SESWIN with 24-Bit Data Recording
User Profiles / Reset to Factory Defaults
Serial/Udp Input/Output Connections
SESWIN Screen
SESWIN Menu Bars
SESWIN Info Sidebar
SESWIN SBP Signal Display and Depth Ruler
SESWIN Sidescan Signal Display ("Light-Plus" / "Standard-Plus")
SESWIN Status Bar
SESWIN Home Menu Bar
Home - General
Home - Range Settings ("Smart" Model Only)
Home - Range (All Other Models)
Home - Gain SBP
Home - Gain SSS ("Light-Plus" and "Standard-Plus" Only)
Home - Transmit SBP (Not for "Smart" Model)
Home - Depth
SESWIN View Menu Bar
View - Sub-Bottom Processing
View - Sidescan Processing
View - Thresholds
View - Colours
View - SBP Display Style
SESWIN System Setup - Settings
System Setup - Settings - General
System Setup - Settings - General - System
System Setup - Settings - General - Synchronisation
System Setup - Settings - General - Files
System Setup - Settings - General - Sidescan Options
System Setup - Settings - General - Special Transmit Modes
System Setup - Settings - General - Beam Steering Options
System Setup - Settings - Navigation Input (GNSS)
System Setup - Settings - Navigation Input - NAV Input Monitor
System Setup - Settings - Navigation Input - Coordinate Conversion
System Setup - Settings - Navigation Input - NAV Data Processing
System Setup - Settings - Navigation Input - Transducer Offsets
System Setup - Settings - Motion Input
System Setup - Settings - Multi Input
System Setup - Settings - Depth Output
System Setup - Settings - Marker
System Setup - Settings - Config Network
System Setup - Settings - Save Settings
System Setup - Settings - Screenshot of All Settings
SESWIN System Setup - Appearance
SESWIN System Setup - System
System Setup - System - System Information
System Setup - System - Dummy Load Measurement
System Setup - System - System Status
SESWIN Network
Network - Broadcast (RAW Data)
Network - Broadcast (Net Viewer)
5 SBP Synchronisation (Trigger Modes) / 1-PPS
Internal Synchronisation
External Synchronisation
Simple External Synchronisation
External Synchronisation with Delay
External Synchronisation with Increased Ping Rate (Bursts)
External Trigger with Delay and Ping Rate Increase
External Trigger - What to Keep in Mind
Alternating Trigger
Sub-Bottom Multi-Ping Mode / Burst Mode (Not for "Smart")
1-PPS Input
6 How to
How to Avoid the Engine's Noise / Proper Transducer Mounting
How to Set up Transducer Draught and Sound Velocity
Where to Set up Transducer Draught and Sound Velocity
How to Get the Transducer Draught
How to Get the Sound Velocity
How to Perform a Bar Check to Calibrate the System
How to Set up Navigation Data Interface (SIS)
Serial Interface Settings
Get Values from NMEA Data
Synchronize the PC Clock to UTC
Get Values from Non-NMEA Data
Save and Reload SIS Settings
Replace SIS Strings with Other Data
How to Set up UTM Conversion
Position Data Source / Destination
Conversion Settings
How to Install and Set up a Motion Sensor
Motion Sensor Installation
SESWIN Motion Sensor Setup
Motion Sensor Test
How to Avoid Interference with Other Acoustic Systems
Synchronizing / Triggering - General Remarks
Nnomar
How to Synchronize a Sparker at a Fixed Ping Rate
How to Use the Broadcast Server to Display Data on HYPACK
How to Use Seswin's Documentation and Report Tools
Document SESWIN System and Interface Settings
Log Files for Work Reports / Profile Lists
System Information and LOG Files for Troubleshooting
How to Reset to Factory Defaults
How to Remote-Control an Innomar SBP
Operating the Innomar System Via KVM Extender
Operating the Innomar System Via Rs232/Ethernet Connection
7 Maintenance and Error Handling
Hardware Handling and Maintenance
Transducer
Transducer Visual Inspection
Hull-Mounted Transducers
Topside Unit Handling
Topside Unit Maintenance
System-Check
Hardware Related Issues
The Voltage Indicators (Leds) at the Front Panel Are Not Illuminated
The Internal Display Is Switched off if an External Monitor Is Connected
The Internal Display Is White. the PC Seems Not to Boot
SESWIN Error Messages at System Start
SESWIN Error and Warning Messages at System Setup
Other SESWIN Error and Warning Messages
No Incoming Sensor Data
No Data or Instable from the Motion Sensor
No Incoming Position Data
SESWIN Functions Seem Not to Work
Transmitters Can't be Switched on
Changing the "Range" Is Impossible
Data-Recording Is Not Possible
The Output "Depth Out" Does Not Work
Signal Detection Problems
No Seafloor on the Screen
The Echo Signal Is too Small
Firmware Update
8 SES Netviewer Software
9 SES Convert Software
Example Data at Innomar's ISE Post-Processing Software
Convert Innomar Data into SEG-Y Format Using SESCONVERT
SEG-Y Conversion Settings
SEG-Y Processing Settings
Data Conversion
Checking the SEG-Y Files
Store / Reload Conversion Settings
10 ISE Post-Processing Software
11 Data Acquisition and Post-Processing Workflow
Survey Preparation and Survey Line Planning
System Setup and Mobilisation
Data Acquisition
Data Acquisition: Example Settings
Data Quality Check (Innomar ISE Software)
Post Processing (Innomar ISE Software)
SEGY Data Export (Innomar SES-Convert Software)
12 FAQ (Frequently Asked Questions)
System Performance
I Do Not Get the Seabed Echo
I Do Not Get a Seabed Echo in the HF Channel
There Is no Data File Recorded
Transmitters Are Not Switched on During Data Recording
How Can I Reduce Acoustic Interference with MBES
What Is the Difference between the Innomar Data Formats
How Do I Get "SES" Like Echo Plots from "RAW" and "SES3" Data Files
Are There Shortcuts to Operate SESWIN with the Keyboard
How Can I Get a Mouse Pointer that Is Better to Recognize
HF (100 Khz) Data Channel
How Can I Switch off the HF Channel
How Can I Switch off HF Data Recording
How Can I Reduce the HF Transmit Power
Trigger / Synchronization
How Can I Reduce the Ping Rate
How Can I Get a Fixed Ping Rate
How Can I Synchronize a Sparker that Runs at a Lower Ping Rate
Motion Sensor / Motion (Heave/Roll/Pitch) Compensation
Do I Need a Motion Sensor
Is a Motion Sensor Included in the Innomar SBP
What Does "Beam Steering" or "Beam Stabilization" Mean
Shipping / Transport / Storage
Shall I Remove / Declare Lithium Batteries
How Do I Pack the Equipment for Transport
How Shall I Put the SBP in Store
Do I Need an RMA Number for Sending the Equipment to Factory
Appendix
Technical Specification SES Smart
Technical Specification SES Compact
Technical Specification SES Light
Technical Specification SES Light-Plus
Technical Specification SES Standard
Technical Specification SES Standard-Plus
Technical Specification SES Medium-100
Transducer for SES Smart
Transducers SES Compact / Light / Standard
Transducers for SES Medium-100
Sidescan Extension for SES Compact
Innomar SBP Data Acquisition and File Formats
GNSS) NMEA Sentences
Motion Sensor Data Formats
Checklists (Setup, Data Acquisition, Processing)
User Feedback Form
Advertisement
Quick Links
1
Seswin Screen
2
Ses Convert Software
Download this manual
Innomar SES
Narrow-Beam Parametric Sub-Bottom Profilers
SES smart
SES compact
SES light / -plus
SES standard / -plus
SES medium-100
User's Manual
SESWIN
SES NetViewer
SES Convert
2020-09
SES Model:
S/N:
Table of
Contents
Previous
Page
Next
Page
1
2
3
4
5
Advertisement
Table of Contents
Need help?
Do you have a question about the SES medium-100 and is the answer not in the manual?
Ask a question
Questions and answers
Related Manuals for innomar SES medium-100
Measuring Instruments innomar SBP smart User Manual
(222 pages)
Measuring Instruments innomar SBP medium-100 User Manual
(222 pages)
Measuring Instruments innomar SES smart User Manual
Narrow-beam parametric sub-bottom profilers (197 pages)
Summarization of Contents
Innomar SES Important Hints and Safety
Safety Rules for Innomar SES Systems
Essential safety guidelines for operating the INNOMAR SBP system and its components.
Innomar SBP User Manual Overview
Description of the manual's structure and how to interpret its content.
System Contents: What is Shipped
Details of the components included in the Innomar SBP system delivery.
Hardware and System Installation Guide
System Overview and Technical Specifications
General overview of INNOMAR SBP models and their technical specifications.
Transducer Handling and Installation Procedures
Guidelines for safe handling, installation, and maintenance of the SBP transducer.
Topside Unit and Front Panel Setup
Instructions for installing the topside unit and understanding front panel connectors.
Rear Panel and Connector Details
Description of connectors and switches on the Innomar SBP rear panel.
Network and Software Configuration
Ethernet and WiFi Setup for Smart/Compact Models
Steps for configuring network connections for SESWIN software operation.
Starting and Navigating SESWIN Software
Guide to launching and navigating the SESWIN software interface and menus.
SESWIN System Setup and Configuration Options
Detailed setup for system parameters, navigation, motion sensors, and synchronization.
SBP Synchronization and Triggering Modes
Internal and External Synchronization Methods
Configuration for internal, external, and alternating trigger modes for SBP synchronization.
1-PPS Input for Time Synchronization
Using the 1-PPS signal for precise time synchronization of the system.
Operational How-Tos and Troubleshooting
Avoiding Engine Noise and Proper Transducer Mounting
Techniques to minimize engine noise interference and ensure correct transducer placement.
Setting Transducer Draught and Sound Velocity
Procedure for setting transducer draught and sound velocity for accurate depth measurements.
Configuring Navigation Data Interface (SIS)
Setting up the SIS interface for receiving and recording navigation data.
Troubleshooting SESWIN Functions and Signal Detection
Resolving issues with SESWIN functions, transmitters, data recording, and signal detection.
Handling No Incoming Sensor Data
Diagnosing and resolving issues with missing motion sensor or position data.
Maintenance, Error Handling, and Firmware
Hardware Handling, Maintenance, and Inspection
Procedures for maintaining and inspecting hardware components like transducers and topside units.
Troubleshooting Common Hardware Issues
Addressing hardware-related problems such as unlit LEDs or display issues.
SESWIN Error and Warning Messages Guide
Explanation and solutions for various error and warning messages during SESWIN operation.
Firmware Update Procedure
Steps for updating the firmware of the Innomar SBP topside unit.
Data Conversion and Post-Processing
Converting Innomar Data to SEG-Y Format
Guide to converting INNOMAR data files into SEG-Y format using SESCONVERT.
Overview of ISE Post-Processing Software
Introduction to the ISE software for data processing and analysis.
Data Acquisition Workflow and Example Settings
Typical workflow for data acquisition and suggested parameter settings.
Frequently Asked Questions (FAQ)
System Performance and Troubleshooting
Answers to common questions regarding system performance and seabed echo detection.
Triggering, Synchronization, and Motion Sensor Issues
Resolving common questions about trigger modes, synchronization, and motion sensor data.
SESWIN Keyboard Shortcuts and Mouse Pointer
Tips for efficient SESWIN operation using keyboard shortcuts and pointer adjustments.
Technical Specifications and Checklists
SES smart Technical Specifications
Detailed technical parameters for the INNOMAR SES smart model.
SES compact Technical Specifications
Detailed technical parameters for the INNOMAR SES compact model.
SES light-plus Technical Specifications
Detailed technical parameters for the INNOMAR SES light-plus model.
Innomar SBP Data Acquisition and File Formats
Overview of data acquisition methods and available file formats for INNOMAR SBP systems.
Checklists for Setup, Acquisition, and Processing
Comprehensive checklists for system setup, data acquisition, and post-processing tasks.
Table of Contents
Save PDF
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL
Need help?
Do you have a question about the SES medium-100 and is the answer not in the manual?
Questions and answers